• Title/Summary/Keyword: Solid environmental samples

Search Result 243, Processing Time 0.023 seconds

Measurement Theory Development of Suspended Solid Concentration Using Glass Fiber Membrane Module (유리섬유 분리막 모듈을 이용한 부유물질 농도의 측정 원리 개발)

  • Park, Jin-Yong;Jung, Wan
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.268-276
    • /
    • 2009
  • In this study the basic data were settled down to establish theory of membrane module and apparatus for measuring suspended solid per particle size. The theory and technique were different with the conventional weight method and light scattering method. For this purpose silica, dextran, kaolin, and PEG (polyethylene glycol) suspended solutions were filtrated through glass fiber membranes GF/C and GF/A on membrane module for measuring TMP (Trans-membrane pressure) changes using digital pressure gages. And the related equation between modified solution concentration and TMP change slope was derived from the TMP change experiments, and then suspended solid concentration of samples could be expected by the equation.

Isolation of Environmental Mycobacteria from Diverse Water Samples Using Cetylpyridinium Chloride

  • Choi, Yeon-Im;Jin, Hyun-Woo;Lee, Gyu-Sang;Kim, Jong-Bae;Song, In-Kenn;Kim, Young-Joon;Lee, Hye-Young
    • Biomedical Science Letters
    • /
    • v.16 no.3
    • /
    • pp.133-138
    • /
    • 2010
  • Despite of the increasing importance of environmental mycobacteria, detection and identification of mycobacteria from environmental sources including water have been fraught with technical difficulties. Although, several protocols to optiruize isolation of mycobacteria from water sources have been reported, standard method has not yet been established. In this study, usefulness of cetylpyridinium chloride (CPC), a cationic quaternary ammonium compound, for the isolation of environmental mycobacteria from diverse water samples was evaluated. For this, water samples from diverse water sources such as effluent water, lake water, and underground water were collected, treated with diverse concentrations of CPC, and plated on the solid agar plates. Subsequently individual colonies grown on the plates were sequence analyzed for identification of each colony. In brief, the results from this study showed that the growth of mycobacteria was enhanced by use of CPC as a pre-treatment reagent to water samples by inhibiting growth of other non-mycobacteria in water. In fact, the effect of CPC to decontaminate non-mycobacteria for isolation of mycobacteria was better than 1~4% of NaOH, which is a routinely used decontaminating reagent widely employed for culturing mycobactera from sputum specimens. Therefore, the results from this study seems to support that the CPC pre-treatment may be useful for isolation of mycobacteria from diverse sources including clinical specimens which are often contaminated with other bacteria.

Simultaneous Determination and Occurrences of Pharmaceuticals by Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) in Environmental Aqueous Samples

  • Koo, So-Hyun;Jo, Cheon-Ho;Shin, Sun-Kyoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1192-1198
    • /
    • 2010
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in the aquatic environment. Many pharmaceuticals are not completely removed during wastewater treatment, leading to their presence in wastewater treatment effluents, rivers, lakes, and ground water. Here, we developed analytical methods for monitoring ten pharmaceuticals from surface water by LC/ESI-MS/MS. For sample clean-up and extraction, MCX (mixed cation exchange) and HLB (hydrophilic-lipophilic balance) solid-phase extraction (SPE) cartridges were used. The limits of detection (LOD) in distilled water and the blank surface water were in the range of 0.006 - 0.65 and 1.66 - 45.05 pg/mL, respectively. The limits of quantitation (LOQ) for the distilled water and the blank surface water were in the range of 0.02 - 2.17 and 5.52 - 150.15 pg/mL, respectively. The absolute recoveries for fortified water samples were between 62.1% and 125.4%. Intra-day precision and accuracy for the blank surface water were 2.9% - 24.1% (R.S.D.) and -16.3% - 16.3% (bias), respectively. In surface wastewater near rivers, chlortetracycline and acetylsalicylic acid were detected frequently in the range of 0.017 - 5.404 and 0.029 - 0.269 ng/mL, respectively. Surface water near rivers had higher levels than surface water of domestic treatment plants.

High-Performance Liquid Chromatographic Determination of Cyclosulfamuron Residues in Soil, Water, Rice Grain and Straw

  • Lee, Young-Deuk;Kwon, Chan-Hyeok
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.251-257
    • /
    • 2004
  • Analytical methods were developed to determine cyclosulfamuron residues in soil, water, rice grain and straw using high-performance liquid chromatography (HPLC) with ultraviolet absorption detection. In these methods, cyclosulfamuron was extracted with aqueous $Na_2HPO_4$/acetone and acetone/methanol mixture from soil and rice samples respectively. Liquid-liquid partition coupled with ion-associated technique, Florisil column chromatography, and solid-phase extraction (SPE) were used to separate cyclosulfamuron from interfering co-extractives prior to HPLC analysis. For water sample, the residue was enriched in $C_{18}$-SPE cartridge, cleaned up in situ, and directly subjected to HPLC. Reverse-phase HPLC under ion-suppression was successfully applied to determine cyclo-sulfamuron in sample extracts with the detection at its ${\lambda}_{max}$ (254 nm). Recoveries from fortified samples averaged $87.8{\pm}7.1%$ (n=12), $97.3{\pm}7.2%$ (n=12), $90.8{\pm}6.6%$ (n=6), and $78.5{\pm}6.7%$ (n=6) for soil, water, rice grain and straw, respectively. Detection limits of the methods were 0.004 mg/kg, 0.001 mg/L, 0.01 mg/kg and 0.02 mg/kg for soil, water, rice grain and straw samples, respectively.

Method for the Analysis of Polybrominated Biphenyls(PBBs) in Environmental Samples (환경시료 중 폴리브롬화비페닐(Polybrominated Biphenyls) 분석법)

  • Shin, S.K.;Kim, T.S.;Hwang, S.Y.;Lee, W.S.;Chung, Y.H.;Na, J.G.
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.300-316
    • /
    • 2002
  • The extraction methods of PBBs from environmental samples by soxhlet extraction for solid phase and liquid-liquid extraction for liquid phase were compared. After extraction, silicagel and florisil as column clean up methods were used for the comparison of cleanup efficiency with different solvent system. Also, the analytical instruments were used GC/MSD. The 22 kinds of PBBs standards were used to establish the analytical methods to perform the experiments of recoveries and detection limits in water and soil. The detection limits of PBBs represented 5~10 ng/L for water and 0.5~3.5 ng/g for soil samples, respectively. The recoveries of water samples represented 96~107% in n-hexane, dichloromethane and toluene for water, and 60~80% in combined solvent with n-hexane and acetone. The recoveries of soil sample were surveyed 67~97% in soxhlet extraction and 64~76% in ultrasonic extraction with selected solvents.

Determination of acidic pharmaceuticals in aquatic environmental samples by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 수질 환경 시료 중 산성의약물질 분석방법 비교)

  • Sim, Young-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2008
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in aquatic environmental samples. Therefore, it required rapidly and certainly analytical method for pharmaceuticals which are existed in environment. In this study, Liquid chromatography/tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) was used to measure the concentrations of 7 pharmaceuticals (quinoxaline-2-carboxylic acid, acetylsalicylic acid, diclofenac-Na, naproxen, ibuprofen, mefenamic acid, talniflumate) from environmental water or aquatic samples simultaneously. Effective sample clean-up by solid-phase extraction (SPE) prior to LC-MS/MS analysis is necessary. For further purification, Mixed Cation eXchange (MCX) and Hydrophilic-Lipophilic Balance (HLB) solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. LODs (Limits of Detection) and MDLs (Method Detection Limits) for the spiked sample in fresh water were in the range of 0.05~1.50 pg/mL and 0.17~4.90 pg/mL, respectively. The absolute recovery in the concentration of 1.0 ng/mL were between 81.9 and 116.3%. The acidic pharmaceuticals were detected in concentrations of 0.018~16.925 ng/mL in aquatic environmental samples.

Profiling Patterns of Volatile Organic Compounds in Intact, Senescent, and Litter Red Pine (Pinus densiflora Sieb. et Zucc.) Needles in Winter

  • CHOI, Won-Sil;YANG, Seung-Ok;LEE, Ji-Hyun;CHOI, Eun-Ji;KIM, Yun-Hee;YANG, Jiyoon;PARK, Mi-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.591-607
    • /
    • 2020
  • This study was aimed to investigate the changes of chemical composition of the volatile organic compounds (VOCs) emitted from red pine needles in the process of needle abscission or senescence. The VOCs in intact, senescent, and litter red pine needle samples were analyzed by headspace-solid phase microextraction gas chromatography-mass spectrometry (HS-SPME-GC/MS). And then, multivariate statistical interpretation of the processed data sets was conducted to investigate similarities and dissimilarities of the needle samples. Principal component analysis (PCA) and orthogonal partial least squares discriminant analysis (OPLS-DA) were used to investigate the dataset structure and discrimination between samples, respectively. From the data preview, the levels of major components of VOCs from needles were not significantly different between needle samples. By PCA investigation, the data reduction according to classification based on the chlorophyll a / chlorophyll b (Ca/Cb) ratio were found to be ideal for differentiating intact, senescent, and litter needles. The following OPLS-DA taking Ca/Cb ratio as y-variables showed that needle samples were well grouped on score plot and had the significant discriminant compounds, respectively. Several compounds had significantly correlated with Ca/Cb ratio in a bivariate correlation analysis. Notably, the litter needles had a higher content of oxidized compounds than the intact needles. In summary, we found that chemical compositions of VOCs between intact, senescent, and litter needles are different each other and several compounds reflect characteristic of needle.

GC/MS-SIM for the Determination of Alkylphenols, Chlorophenols and Bisphenol A in Paper Materials

  • Kim, Hyub
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.145-145
    • /
    • 2003
  • A method for the determination of alkylphenols, chlorophenols and bisphenol A in paper materials using GC/MS-SIM has been developed. Eleven endocrine disrupting chemicals (EDCs) of phenols in paper samples were extracted with acetonitrile. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 82.4∼108.8 % by area ratio of pheranthrene-d$\sub$10/ vs bisphenol A d$\sub$l6/. (isoBOC derivatization and TBDMS derivatization) The SIM responses were linear with the correlation coefficient varying 0.9717∼0.9995 (isoBOC derivatization), and 0.9842∼0.9980 (TBDMS derivatization). The range of concentrations was respectively, 0.95∼l.44 ng/g in 2,4-dichlorophenol, 1.01∼1.17 ng/g in t-butylphenol, 2.17∼5.84 ng/g in pentachlorophenol, 12.68∼14.88 ng/g in nonylphenol and 30.84∼153.72 ng/g in bisphenol A.

  • PDF

Part-Per-Trillion level determination of Alkylphenols, Chlorophenols and Bisphenol A using GC/MS-SIM in Tap Water

  • Kim, Hyub
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.149-149
    • /
    • 2003
  • A new technique is proposed for the determination of alkylphenols, chlorophenols and bisphenol A in tap water. The sample preparation consists of a solid phase extraction (SPE) of alkylphenols, chlorophenols and bisphenol A from a water sample with XAD-4 and subsequent conversion to isobutyloxycarbonyl (isoBOC) derivatives or tert.-butyldimethylsilyl (TBDMS) derivatives for sensitive analysis with the GC/MS-SIM mode. The recoveries were 86.6∼105.2 % (isoBOC derivatization) and 97.6∼484.5 % (TBDMS derivatization), respectively. The limit of quantitation of alkylphenols, chlorophenols and bisphenol A for SIM were 0.001∼0.050 $\mu\textrm{g}$/l (isoBOC derivatization) and 0.003∼0.050 $\mu\textrm{g}$/l (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755∼0.9981 (isoBOC derivatization), and 0.9908∼0.9996 (TBDMS derivatization). The derivative methods and their application to tap water samples will be disscussed.

  • PDF

Immobilization of the Thenoyltrifluoroacetone on Sodium Dodecyl Sulfate Modified Magnetite Nanoparticles for Magnetic Solid Phase Extraction of Pb (II) from Water Samples

  • Sadeghi, Meysam;Yekta, Sina;Babanezhad, Esmaeil
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.636-647
    • /
    • 2016
  • Magnetite nanoparticles ($Fe_3O_4$ NPs) were synthesized by co-precipitating method under optimized condition. The $Fe_3O_4$ NPs coated with sodium dodecyl sulfate-thenoyltrifluoroacetone ($Fe_3O_4$ NPs-SDS-TTFA) were then exerted as the magnetic solid phase extraction (MSPE) adsorbent for the extraction process prior to introducing to a flame atomic adsorption spectrometry (FAAS). The synthesized $Fe_3O_4$ NPs-SDS-TTFA were applied for the extraction of Pb(II) ions from different water samples. The characterization studies of nanoparticles were performed via scanning electron microscopy-energy dispersive micro-analysis (SEM-EDAX), X-ray diffraction (XRD) and vibrating sample magnetometer (VSM) techniques. The substantial parameters affecting the extraction efficiency were surveyed and optimized. A dynamic linear range (DLR) of $10-400{\mu}g\;L^{-1}$ was obtained and the limit of detection (LOD, n=7) and relative standard deviation (RSD%, n= 6, $C=20{\mu}g\;L^{-1}$) were found to be $2.3{\mu}g\;L^{-1}$ and 1.9%, respectively. According to the results, the proposed method successfully applied for the extraction of Pb(II) ions from different environmental water samples and satisfactory results achieved.