• Title/Summary/Keyword: Solenoid sensor

Search Result 80, Processing Time 0.026 seconds

New and Improved Time-selective Self-triggering Water Sampler: AUTTLE

  • Jin, Jae-Youll;Hwang, Kuen-Choon;Park, Jin-Soon;Eo, Young-Sang;Kim, Seong-Eun;Yum, Ki-Dai;Oh, Jae-Kyung
    • Ocean and Polar Research
    • /
    • v.22 no.2
    • /
    • pp.57-67
    • /
    • 2000
  • Time-selective self-triggering water sampler, AUTTLE developed by Jin et al. (1999) has been improved in order to prevent pre-deposition of suspended sediments (SS) before sampling. By using two solenoids, the improved sampler is able to be moored or deployed with inclination. Its position is changed to horizontal position by activating the first solenoid, and then the endcaps of the sampling bottle are closed by the second solenoid that is driven three times to minimize possible failure of sampling. An external control unit for setting sampling time has been also constructed. Additionally, the electric circuit housing of the sampler has been modified to be detached from the sampling bottle when operating manually. Its performance has been confirmed through flume tests and a field experiment. It will serve as a valuable tool in the various fields of oceanography and environmental engineering, especially where seawater sampling synchronized at several sites and/or the information in storm period is important.

  • PDF

Precision Screw Driver utilizing a Bellows (벨로우즈방식의 정 밀 나사 체결기)

  • 정규원;오의진
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.5
    • /
    • pp.53-59
    • /
    • 2001
  • A screw driver is widely used in assembling machine parts or electronic products such as the printed circuit board with a housing. As the parts to be assembled becomes small and precise, the higher precision of the controlling screw driver torque is required. However, because the operator controls the fastening torque based on experience, it must be inexact and the setting procedure will be time consuming job. Thus the screw driver which can exactly control the fastening torque is developed utilizing a bellows in this paper. The bellows is expanded by the inner air pressure and contracted by the spring operation. The bellows type driver is composed of a clutch mechanism with two solenoid valves and a pressure sensor. Those valves are controlled using the detected bellows pressure by the sensor. When the pressure reaches the setting value, the exit solenoid valve is opened to release the air pressure from the bellows so as not to deliver further torque. Through a series of experiments, the performance is examined and verified.

  • PDF

The Performance of Micro Fluxgate Sensor with Magnetic Core Shape (자성체 코어 형상에 따른 마이크로 플럭스게이트 센서의 검출 특성)

  • 조중희;최원열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.508-514
    • /
    • 2004
  • A fluxgate magnetic sensor consists of a solenoid excitation coil, pick-up coil, and magnetic core. We presents the effect of magnetic core shape in a micromachined fluxgate sensor. To observe the performance of fluxgate sensor with magnetic core side width and gap, side width of 125 ${\mu}{\textrm}{m}$, 250 ${\mu}{\textrm}{m}$, and 500 ${\mu}{\textrm}{m}$ were designed in a rectangular-ring shaped core and the gaps of 0 ${\mu}{\textrm}{m}$, 50 ${\mu}{\textrm}{m}$, and 100 ${\mu}{\textrm}{m}$ were also fabricated in a racetrack shaped core. The solenoid coils and magnetic core were separated by benzocyclobutane(BCB) which had high insulation and good planarization characters. Copper coil patterns of 10 ${\mu}{\textrm}{m}$ width and 6${\mu}{\textrm}{m}$ thickness were electroplated on Ti(300 $\AA$) / Cu(1500 $\AA$) seed layers. 3 ${\mu}{\textrm}{m}$ thick N $i_{0.8}$F $e_{0.2.}$(permalloy) film for the magnetic core was also electroplated under 2000 gauss to induce the magnetic anisotropy. The magnetic core had the high DC effective permeability of ∼1,300 and coercive field of ∼0.1 Oe. Because the magnetic cores of 500 ${\mu}{\textrm}{m}$ side width and 0 gap had a low magnetic flux leakage, high sensitivity of ∼350 V/T were measured at excitation condition of 3 $V_{P-P}$ and 2 MHz square wave. The power consumption of ∼14 ㎽ was measured. The fabricated fluxgate sensor had the very small actual size of 3.0${\times}$1.7 $\textrm{mm}^2$. When two fluxgates were perpendicularly aligned in terrestrial field, their two-axis output signals were very useful to commercialize an electronic azimuth compass for the portable navigation system.m.m.m.

Flower water management system by wireless sensor network (무선센서 네트워크를 활용한 화초 수분관리 시스템)

  • Park, Sang-Gug
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.516-519
    • /
    • 2010
  • In this paper, we propose to improve conventional methods, which measure moisture level in the soil and supply proper water by a hand operation. Our system use wireless sensor network between sensor node and host PC. The measurement system measure moisture level by use moisture sensor. The control system control electronic solenoid switch and supply proper water automatically.

  • PDF

Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation (덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용)

  • Joo-Hyung Lee;Imjong Kwahk;Changbin Joh;Ji-Young Choi;Kwang-Yeun Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.17-24
    • /
    • 2023
  • A post-processing technique for the measurement signal of a solenoid-type sensor is introduced. The solenoid-type sensor nondestructively evaluates an external tendon of prestressed concrete using the total flux leakage (TFL) method. The TFL solenoid sensor consists of primary and secondary coils. AC electricity, with the shape of a sinusoidal function, is input in the primary coil. The signal proportional to the differential of the input is induced in the secondary coil. Because the amplitude of the induced signal is proportional to the cross-sectional area of the tendon, sectional loss of the tendon caused by ruptures or corrosion can be identified by the induced signal. Therefore, it is important to extract amplitude information from the measurement signal of the TFL sensor. Previously, the amplitude was extracted using local maxima, which is the simplest way to obtain amplitude information. However, because the sampling rate is dramatically decreased by amplitude extraction using the local maxima, the previous method places many restrictions on the direction of TFL sensor development, such as applying additional signal processing and/or artificial intelligence. Meanwhile, the proposed method uses amplitude demodulation to obtain the signal amplitude from the TFL sensor, and the sampling rate of the amplitude information is same to the raw TFL sensor data. The proposed method using amplitude demodulation provides ample freedom for development by eliminating restrictions on the first coil input frequency of the TFL sensor and the speed of applying the sensor to external tension. It also maintains a high measurement sampling rate, providing advantages for utilizing additional signal processing or artificial intelligence. The proposed method was validated through experiments, and the advantages were verified through comparison with the previous method. For example, in this study the amplitudes extracted by amplitude demodulation provided a sampling rate 100 times greater than those of the previous method. There may be differences depending on the given situation and specific equipment settings; however, in most cases, extracting amplitude information using amplitude demodulation yields more satisfactory results than previous methods.

Development of a Hydraulic Level Control System for High-speed Rice Transplanting Machines (고속 이앙기의 유압 수평 제어 장치 개발에 관한 연구)

  • 정연근;정병학;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.27 no.2
    • /
    • pp.79-88
    • /
    • 2002
  • This study was conducted to develop system for high speed rice transplanting machines. The control system includes a sensor detecting the tilt angle of the seedling bed, a micro-controller and a hydraulic system consisting of a double acting cylinder, a four-way three-position solenoid valve, a relief valve and a hydraulic pump. The levelling system shared the pump with the existing steering control, resulting in a tandem center circuit for the steering and levelling control systems. Using the input signal from the sensor, the micro-controller determined and generated the output signal to control the cylinder through the solenoid valve to keep the seedling bed always parallel to the water surface regardless of soil unevenness during the transplanting operations. Both an ON/OFF and a PWM control schemes were tested. When the flow rate was more than 1 ι/min in the ON/OFF control, the system showed unstable rolling. However, in the PWM control, the system worked stably although the flow rate was more than 1 ι/min. The PWM control showed a better performance when a large difference between the angle and the dead band of the control system occurred. The characteristics of tile system response to given tilt angles were predicted by a computer simulation. Both the ON/OFF and the PWM control systems worked well providing that the operating and waiting times were properly adjusted.

A Study on the Design and Performance Evaluation Technology of Fieldbus Pneumatic Solenoid Valve/Sensor System (필드버스 공압 솔레노이드 밸브/센서시스템 설계 및 성능평가 특성해석)

  • Kim, D.S.;Hong, C.P.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.865-870
    • /
    • 2001
  • For pneumatic system control, we need a data transmission system with high speed and high reliability or information interchange between main computer and solenoid valves and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid valves. In addition we developed a communication protocol for construction of RS-485 based multidrop network, and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. The field test results show that, even under high noise environment, the data transmission of 375Kbps rate is possible up to 1,000m without using repeater. In addition, the system developed in this research is proved to be used easily for extension of a communication network because of its module structure.

  • PDF

Design and Fabrication of Miniaturized Optical Chopper Operated by Electromagnetic Actuation

  • Kim, Ho Won;Min, Seong Ki;Choi, Young Chan;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.165-169
    • /
    • 2014
  • An existing infrared (IR) analysis system is generally composed of infrared source, IR focusing lenses, IR detector, and optical chopper. An optical chopper is widely used in combination with lock-in amplifier to improve the signal-to-noise ratio by periodically interrupting incident light beam. During recent years, a few researches on miniaturized optical chopper have been reported to apply to micro-scaled optical systems. In this paper, a micro optical chopper operated by electromagnetic actuation is proposed and applied to a miniaturized micro-scaled optical system operating in IR spectral range. Additionally, the fabrication method of the proposed micro chopper is demonstrated. The proposed micro optical chopper is composed of the polydimethylsiloxane (PDMS) membrane, solenoid, and permanent magnet. The permanent magnet is bonded on the PDMS membrane using an ultraviolet-activated adhesive. The operation of the chopper is based on the attractive and repulsive forces between permanent magnet and solenoid induced by an electrical current flowing through the solenoid. The fabricated micro optical chopper could operate up to 200 Hz of frequency. The maximum operating distance of the chopper with 7mm diameter membrane was $750{\mu}m$ at 100 Hz of frequency.

Precise Temperature Control by Adjusting Flow of Liquid Nitrogen (액체 질소의 흐름 조절을 통한 저온 정밀 온도 제어)

  • Yang, Inseok;Lee, Jee-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.65-70
    • /
    • 2016
  • We devised a method to control the temperature of a liquid bath as low as $-100^{\circ}C$ using the duty cycle control of a solenoid valve. The solenoid valve controls the flow of liquid nitrogen that we used as a cryogen in this system. By controlling the duty cycle of a solenoid valve using feedback from the measured temperature of the liquid bath, we were able to achieve temperature stability within ${\pm}19mK$ around $-100^{\circ}C$. We also demonstrated that by taking average values of the temperature readings for sequence of measurements from more than one thermometer, it is possible to use this system for the calibration of thermometers within 3 mK. This system and the control method can be used for the precise temperature control in the range between $0^{\circ}C$ and $-100^{\circ}C$, where commercially available precision baths are much expensive and hard to be built in customized configurations.

Development of Intelligent Powered Gait Orthosis for Paraplegic

  • Kang, Sung-Jae;Ryu, Jei-Cheong;Moon, In-Hyuk;Kim, Kyung-Hoon;Mun, Mu-Seung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1272-1277
    • /
    • 2005
  • In this study, we wolud be developed the fuzzy controlled PGO that controlled the flexion and the extension of each PGO's joint using the bio-signal and FSR sensor. The PGO driving system is to couple the right and left sides of the orthosis by specially designed hip joints and pelvic section. This driving system consists of the orthosis, sensor, control system. An air supply system of muscle is composed of an air compressor, 2-way solenoid valve(MAC, USA), accumulator, pressure sensor. Role of this system provide air muscle with the compressed air at hip joint constantly. According to output signal of EMG sensor and foot sensor, air muscles and assists the flexion of hip joint during PGO gait.

  • PDF