• 제목/요약/키워드: Solar water heating system

검색결과 215건 처리시간 0.02초

공동주택의 배치 및 블록별 재생에너지 시스템의 적용성에 관한 연구 (A Study on the Application Strategies of Renewable Energy Systems Considering Layout and Block Plan in Apartment Building)

  • 이관호
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.79-87
    • /
    • 2006
  • This study aims to presents the applicability of apartment building for renewable energy systems using method of uncomplicated calculation and computer simulation. According to the weather conditions (NASA Surface meteorology and Solar Energy) analysis, it has been found that photovoltaic and wind power system can be applied to apartment buildings application. In case study considering layout and block plan, adaptation of solar water heating, photovoltaic and wind energy system to apartment buildings was proved to produce a profit. And the application strategies of renewable energy systems can be used not only for the investment decisions for economic analysis but also for the comparative analysis of uncomplicated calculation and computer simulation.

6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제3보 최적설계 및 경제성평가) (Verification Experiment and Analysis for 6kW Solar Water Heating System(Part 3 : Optimum Design and Economic Evaluation))

  • 최봉수;이봉진;강채동;홍희기
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.16-24
    • /
    • 2005
  • The goal of the present paper is to show the optimum design and operation conditions on 6 kW solar water heating system by using computer simulation with verified modelling. As the object functions, we took not only the amount of acquired and auxiliary heat but LCC, which has a relative importance and decisive role in economy. As expected, the maximum heat is acquired at the slope of collector with the equal degree to the latitude, facing the south. The capacity increase of the circulation pump and the storage tank lead to the increase of acquired heat and the decrease of auxiliary heat, but do not necessarily give economical advantages owing to additional electrical power consumption. In the present system, the minimum LCC can be obtained at the storage tank volume of 450 L and the mass flow rate of 0.344 kg/s.

복합형 태양열 가열기 열매체 동시운전시의 열적 성능에 관한 실험적 연구 (Experimental Study for Thermal Performance of Hybrid Air-Water Heater Using Solar Energy during Heating Medium Working Simultaneously)

  • 최광환;윤정인;손창효;최휘웅;김부안
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.115-121
    • /
    • 2014
  • With increment on interesting about improving renewable energy efficiency, many research have been conducted and the research about hybrid air-water heater using solar energy that can make heating air and hot water has been conducted also. In this experiment, the temperature difference and thermal efficiency were investigated when two heating medium(air and liquid) was working simultaneously. As a result, thermal efficiency showed 44% to 88% when these heating medium was working simultaneously depending on operation condition and it is better than traditional solar collector. Also possibility of application into building equipment also was confirmed based on temperature and thermal efficiency. But necessity of additional studies about proper operation condition according to purpose of use and heat load was confirmed because change of thermal efficiency by air velocity and flux of liquid was shown a huge difference.

강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구 (A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method)

  • 박형수;김철호
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.122-126
    • /
    • 2017
  • 태양열 에너지를 이용하여 단순한 형태의 공기가열식 집열기를 이용하여 공기를 가열하고 이를 활용하여 생활공간의 난방문제를 해결하기 위한 장치를 개발하는데 목적을 두고 진행되고 있다. 현 시점에서 연구는 모델로 개발한 공기가열식 태양열에너지 집열기의 크기 변화에 따른 가용한 에너지의 량을 이론적으로 산출해 보고 이를 통해 개발 시스템의 가능성을 판단하고자 한다. 본 연구에서는 공기가열식 태양열 집열기의 공기가열성능을 판단하기 위하여, 특정 크기의 태양열 집열기에 일정한 일사량을 투하하였을 때, 모델 집열기 내부에서의 열전달 특성변화와 이를 통해 생산되는 공기의 온도($^{\circ}C$)와 생산량(kg/h)을, 유한체적법(Finite Volume Method)을 적용한 범용 열유동해석(CFD) 프로그램인 영국 CHAM사의 PHOENICS(1)를 이용하여, 분석한 결과를 구하였다. 분석한 결과에서 알 수 있듯이 집열기의 크기가 ($1.2m{\times}1.1m{\times}0.19m$)의 집열기에서 알루미늄으로 제작하는 내경 0.1m의 공기 가열관을 이용하여 가열할 수 있는 공기의 온도는 약 $40.5^{\circ}C$이며 이때 생산되는 공기의 생산량은 약 $161m^3/h$으로 산출되었다. 본 모델장치는 충분히 태양의 열에너지를 이용하여 실내공간의 온도를 인간이 활동하기에 적합한 활동의 환경을 유지하는데 활용할 수 있다고 판단된다.

공기식 태양열 난방계통의 성능실험 (Performance Tests on an Air Solar Heating System)

  • 남평우;차종희
    • 대한설비공학회지:설비저널
    • /
    • 제8권2호
    • /
    • pp.81-88
    • /
    • 1979
  • The performance of air type solar heating system has been investigated for a system which has been operating continuously for two years. Design factors of a collector, such as the effective transmittance-absorptance and heat transfer factor were also determined experimentally. The flat plate collector is fabricated from steel sheet metal with two sealed glass covers. Solar heat is stored in a pebble bed of primarily granitic rock approximately 20-40 mm in diameter. The system is controled by automatically driven motors and dampers. The ratio of useful collected solar heat divided by the total solar radiation on the collector dropped was the range of 35 to 42 percent in monthly average. As it result, the air system was found fairly competitive with the water system, however, the heat supply from storage was limited because of using the pebble as the heat storage media.

  • PDF

공기열원 2중히트싱크 열펌프의 성능해석 (Performance Analysis of Heat Pump System with Air Source Evaporator and Single Unit Dual Sink Condenser)

  • 우정선;이세균;이재효;박효순
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.11-22
    • /
    • 1998
  • Floor panel heating system using hot water is the primary heating system of domestic residential building. This paper presents the results of performance analysis of the heat pump system with air source evaporator and single unit dual sink(SUDSk) condenser. The heat exchanger combines two separated condensers into a single condenser and the object of the SUDSk condenser is to release energy to dual sinks, i.e. air for air heating system and water for panel heating system in one single unit. Simulation program is developed for single unit dual source(SUDS) SUDSk heat pump system and some experimental data are obtained and compared with simulation results. Differences of heating capacity and COP in dual source operating mode are 7% and 8% respectively. Simulation results are in good agreement with test results. Therefore, developed program is effectively used for design and performance prediction of dual source dual sink heat pump system with SUDS evaporator and SUDSk condenser.

  • PDF

남부지역의 태양열이용 열펌프식 온수.난방시스템의 실증연구 분석 (Analysis of demonstration research on solar heat pump system for room and hot water heating in the southern part of South Korea)

  • 선경호;김기선
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.198.1-198.1
    • /
    • 2010
  • 우리나라 남부지방은 대체적으로 태양 일사량이 풍부하여 태양열 시스템의 설치조건으로는 가장 좋은 지역이다. 현재까지 국내에 보급된 태양열 시스템은 외기조건이 불량한 경우에는 비효율적이다. 최근 태양열 온수기는 전국적으로 매우 활발히 보급되고 있고 태양열 온수기에 대한 일반인들의 인식은 그 어느 때보다 높다고 할 수 있다. 태양열이용 열펌프시스템 기술은 소형 온수기에의 적용 뿐 아니라 건물의 난방기술에도 적용되고 있다. 본 연구에서는 태양열 집열기 직접 팽창식 열펌프시스템(이하 '태양열 시스템')의 열성능 효율 향상에 가장 많이 기여하는 팽창장치와 롤본드형 태양열집열기에 대하여 실험하였고 현장 적용가능성을 분석하였다. 또한 태양열 열펌프식 온수 및 난방시스템의 한국의 남부지방에서의 적용가능성은 지난 관련연구결과를 분석하여 비교하여 모색하였다.

  • PDF

지열 이용 히트펌프 시스템의 열성능 해석 (Analysis of Thermal Performance of Ground-Source Heat Pump System)

  • 신우철;백남춘;김욱중;고득용
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.95-101
    • /
    • 2006
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of the Ground-Source Heat Pump(GSHF) system. The calculation was performed for two design factors: the spacing between boreholes and the depth of the vertical ground heat exchangers. And the simulation was carried out using the thermal simulation code TRNSYS with new model of water to water heat pump developed by this study. As a result, it was anticipated that the yearly mean COPs of heat pump for heating and cooling are about 3.7 and 5.8 respectively and the heat pump can supply 100% of heating and cooling load all the year around.

태양열 급탕시스템의 최적화 운전을 위한 열성능 분석 (Thermal Performance Analysis for Optimal Operation of Solar Hot Water System)

  • 신우철;윤종호;백남춘;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.143-147
    • /
    • 2011
  • On-off differential controller is one of the very important component which has influence on the system performance of the solar hot water system. In this study, it was analysed the influence of "on-off" setting temperature on the system efficiency and the electrical consumption by circulation pump. This study was performed by computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results.

지열-태양열원 복합시스템의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Hybrid Energy System with Geothermal and Solar Heat Sources)

  • 황인주;우남섭;이홍철
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.279-286
    • /
    • 2006
  • The present study concerns the annual performance evaluation of a hybrid-renewable energy system with geothermal and solar heat sources for hot water, heating and cooling of the residential buildings. The hybrid energy system consists of ground source heat pump of 2 RT for cooling, solar collectors of $4.8m^2$, storage tank of 250 liters and gas fired backup boiler of 11.6 kW. The averaged coefficients of performance of geothermal heat pump system during cooling and heating seasons are measured as 4.1 and 3.5, respectively. Also solar fraction for hot water is measured as 35 percent. Overall, the results shows that the hybrid-renewable energy system satisfactorily operated under all climatic conditions.