• 제목/요약/키워드: Solar ribbon

검색결과 37건 처리시간 0.026초

PV모듈 제조공정에서 Interconnection에 따른 전기적 손실 특성 분석 (The Analysis of electrical loss characteristics by interconnection during PV module fabrication process)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.216-217
    • /
    • 2007
  • In this study, we analyzed the electrical loss characteristics between ribbon and output terminal of constituent material according to electrical resistance during interconnection process of PV module. From this result, the electrical output power reduction rate caused by interaction between ribbon and cell's interconnection was 2.88%. There was 1W electrical output power reduction through the 16 solar cells. So it is expected that the wider size of PV module gives the higher loss in electricity production. Also, the average output power of PV module passed lamination process was increased by 0.081W per one solar cell and the increase rate was 3.7%.PV module's electrical loss before and after lamination process according to constituent material's terminal was 0.49W and 0.50W, respectively.

  • PDF

Three-Dimensional Modeling of the Solar Active Region

  • ;;최광선
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.85.2-85.2
    • /
    • 2012
  • In this paper, we introduce the 3D modeling of the coronal magnetic field in the solar active region by extrapolating from the 2D observational data numerically. First, we introduce a nonlinear force-free field (NLFFF) extrapolation code based on the MHD-like relaxation method implementing the cleaning a numerical error for Div B proposed by Dedner et al. 2002 and the multi-grid method. We are able to reconstruct the ideal force-free field, which was introduced by Low & Lou (1990), in high accuracy and achieve the faster speed in the high-resolution calculation (512^3 grids). Next we applied our NLFFF extrapolation to the solar active region NOAA 10930. First of all, we compare the 3D NLFFF with the flare ribbons of Ca II images observed by the Solar Optical Telescope (SOT) aboard on the Hinode. As a result, it was found that the location of the two foot-points of the magnetic field lines well correspond to the flare ribbon. The result indicates that the NLFFF well capture the 3D structure of magnetic field in the flaring region. We further report the stability of the magnetic field by estimating the twist value of the field line and finally suggest the flare onset mechanism.

  • PDF

열충격 시험을 통한 태양전지 특성에 관한 연구 (A Study on The Characteristics of Solar Cell by Thermal Shock test)

  • 강민수;전유재;신영의
    • 에너지공학
    • /
    • 제21권3호
    • /
    • pp.249-253
    • /
    • 2012
  • 본 연구에서는 열충격 시험을 통하여 Cell 레벨에서의 효율저하 특성을 분석하였다. 열충격 시험은 PV모듈의 시험 규격인 KS C IEC-61215를 이용하여 보다 가혹한 조건인 $-40^{\circ}C$에서 $120^{\circ}C$의 조건으로 500사이클을 수행하였다. I-V 측정을 통하여 효율을 분석한 결과, 열충격 시험 전 13.9%에서 열충격 시험 후 11.0%로 효율이 저하 됐으며, 감소율은 20.9%로 나타났다. EL촬영을 통해 표면을 분석한 결과 Ribbon접합부 및 Gridfinger의 손상으로 확인 됐으며, 보다 정확한 효율 저하의 원인을 분석하기 위해 단면분석을 실시한 결과, 표면손상으로 확인 되었던 위치의 Cell 내부에서도 Crack을 확인할 수 있었다. 또한, FF(Fill Factor)값을 분석한 결과 열충격 시험 전 72.3%에서 시험 후 62.0%로 11.8%의 감소율을 보였다. 따라서, 경년 시 나타나는 효율저하는 I-V 특성 곡선의 변화에 따라 병렬저항($R_{SH}$)이 감소하여 Cell자체의 소모전력 증가 및 표면 손상, Cell 내부의 Crack에 기인하여 가속된다고 판단된다.

폐태양전지(廢太陽電池)용 솔라리본으로부터 구리회수(回收)에 관한 연구(硏究) (Recovery of Copper from Spent Photovoltaic Ribbon in Solar Module)

  • 이진석;장보윤;김준수;안영수;강기환;왕제필
    • 자원리싸이클링
    • /
    • 제22권5호
    • /
    • pp.50-55
    • /
    • 2013
  • 폐 태양광 전지내의 구리리본전극으로부터 구리를 회수하기 위해 불활성 가스분위기하에서 $300-600^{\circ}C$로 열처리 하였다. 구리리본전극의 코팅층은 68.99 wt.%의 납과 31.21 wt.%의 주석으로 구성되어 있는데, 각각의 온도에서 코팅층을 용해한 후 반응도가니에 용해된 코팅층 회수하였다. 열처리 후 회수되어진 코팅층은 ICP-MS (Inductively coupled plasma mass spectrometry)로 성분 분석을 실시하였으며, 온도범위에 관계없이 95 wt.% 이상의 구리순도를 얻을 수 있었다. 구리리본전극 샘플의 횡단면은 SEM (scanning electron microscopy) and EDX (energy dispersive X-ray microscopy)로 관찰하였다.

태양전지 묘듈용 솔드 합금의 산화 특성 (Oxidation characteristics of solder alloys for the photovoltaic module)

  • 김효재;이영은;이구;강기환;최병호
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.98-104
    • /
    • 2014
  • Photovoltaic (PV) cell is considered as one of the finest ways to utilize the solar power. A study of improving solar cell's efficiency is important because the lifetime of solar cell is determined by photovoltaic module technology. Therefore, oxidation (and/or corrosion) of solder materials will be one of the primary yield and long-term reliability risk factor. Recently, the development of lead-free solder alloy has been done actively about lead-free solder alloys of the thermodynamic and mechanical properties. However, the oxidation behavior have rarely been investigated In this study, the oxidations of 60 wt% Sn-40 wt% Pb, 62 wt% Sn-36 wt% Pb -2 wt% Ag, 50wt% Sn-48 wt% Bi-2 wt% Ag alloys for the interconnect ribbon after exposure in atmosphere at $100^{\circ}C$ for several times were investigated. The wettability of 62 wt% Sn-36 wt% Pb-2 wt% Ag and 50 wt% Sn-48 wt% Bi-2 wt% Ag solders was also studied to compare with that of 60 wt% Sn-40 wt% Pb alloy. The results howed that the zero cross time and the wetting time of 50 wt% Sn-48 wt% Bi-2 wt% Ag solder were better than other two samples. The surface of tested samples was analyzed by XPS. The XPS result showed that in all samples, SnO grew first and then the mixture of SnO and $SnO_2$ was detected. $SnO_2$ grew predominantly for the long time aging. Moreover XPS depth profile analysis has found surface enrichment of tin oxide.

SUNSPOT EVOLUTION IN THE VICINITY OF A LARGE SOLAR FLARE IN AR 6891

  • ALMLEAKY Y. M.;MALAWI A. A.;BASURAH H. M.
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.317-319
    • /
    • 1996
  • Utilizing a Calcium filter, a large two ribbon flare of an importance 2.5Xj31? was recorded at. King Abdul-Aziz University Solar Observatory (KAAUSO) at the 30th of October 1991. This chromosphenc flare observation, which is of special importance since it is rarely reported, was for a flare that occurred near the south west of the equator at the vicinity of a large sunspot group on an active region known as AR 6891. The observed foot points of this flare had a strange behavior in which the separating motion of the ribbons were not typical of most flares, rather were nearly orthogonal. In this article we present the characteristics of the main sunspot group of this active region and try to investigate its evolution and fragmentation with time. Information regarding magnetic fields and velocity fields are necessary to understand the restructuring of the magnetic field pattern and plasma motion, and hence the changes that could lead to the occurrence of such an interesting flare.

  • PDF

열충격 시험을 통한 태양전지 특성 (Characteristics of Solar Cell by Thermal Shock test)

  • 강민수;전유재;손선익;김도석;신영의
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.91-95
    • /
    • 2012
  • 본 연구에서는 열충격 시험을 통하여 Cell레벨에서의 효율저하 특성을 분석하였다. 열충격 시험은 PV모듈의 시험 규격인 KS C IEC-61215를 이용하여 보다 가혹한 조건인 $-40^{\circ}C$에서 $120^{\circ}C$의 조건으로 500사이클 수행하였다. I-V 측정을 통하여 효율을 분석한 결과, 열충격 시험 전 13.9%에서 열충격 시험 후 11.0%로 효율이 저하 됐으며, 감소율은 20.9% 나타났다.EL촬영을 통해 표면을 분석한 결과 Ribbon접합부 및 Gridfinger의 손상으로 확인 됐으며, 보다 정확한 효율 저하의 원인을 분석하기 위해 단면분석을 실시한 결과 표면손상으로 확인 되었던 위치의 Cell내부에서도 Crack을 확인 할 수 있었다. 또한 FF값을 분석한 결과 열충격 시험 전 72.3%에서 시험 후 62.0%로 11.8%의 감소율을 보였다. 따라서, 경년 시 나타나는 효율저하는 Cell자체의 소모전력 증가와 외부환경에 의한 표면 손상 및 Cell내부의 Crack에 기인하여 가속된다고 판단된다.

  • PDF

NEW DIGITAL H$\alpha$ OBSERVATION BY SOLAR FLARE TELESCOPE AT BOAO

  • LEE C.-W.;MOON Y.-J.;PARK Y.D.;JANG B.-H.;KIM KAP-SUNG
    • 천문학회지
    • /
    • 제34권2호
    • /
    • pp.111-117
    • /
    • 2001
  • Recently, we have set up a new digital CCD camera system, MicroMax YHS-1300 manufactured by Roper Scientific for Ha observation by Solar Flare Telescope at Bohyunsan Optical Astronomy Observatory. It has a 12 bit dynamic range, a pixel number of 1300$\times$1030, a thermoelectric cooler, and an electric shutter. Its readout speed is about 3 frames per second and the dark current is about 0.05 e-/p/s at $-10^{\circ}C$. We have made a system performance test by confirming the system linearity, system gain, and system noise that its specification requires. We have also developed a data acquisition software which connects a digital camera con-troller to a PC and acquires H$\alpha$ images via Microsoft Visual C++ 6.0 under Windows 98. Comparisons of high quality H$\alpha$ images of AR 9169 and AR 9283 obtained from SOFT with the corresponding images from Learmonth Solar Observatory in Australia confirm that our H$\alpha$ digital observational system is performed properly. Finally, we present a set of H$\alpha$ images taken from a two ribbon flare occurred in AR 9283.

  • PDF

Band gap control by tri-block nanoribbon structure of graphene and h-BN

  • 이지우;정가운
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제4회(2015년)
    • /
    • pp.324-329
    • /
    • 2015
  • First-principles investigations on the hybrid one dementional hexagonal hybrboron-nitride nano ribbons (BNNRs) with a armchair graphene nano-ribbons(AGRNRs), are presented. Electronics properties of the mixed armchair BNC nano-ribbon (BNCNRs) structure show control of a band gap on all cases at the special K-point. And we have studied, the band gap is direct in all cases. The band gap of mixed ABNCNRs could be divided into three groups (${\Delta}3p$, ${\Delta}3p+1$ and ${\Delta}3p+2$) and decrease with the increase of the width. Also these results show similar to the AGNRs case. Different from the band gap value ordering of AGNRs (${\Delta}3p+1$ > ${\Delta}3p$ > ${\Delta}3p+2$), the ordering of ABNCNRs is ${\Delta}3p$ > ${\Delta}3p+1$ > ${\Delta}3p+2$. The discrepancy may come from the differences between the edges of AGRNRs and the boundaries of hybrid BNCNRs. In addition, the bandgap of ABNCNRs are much smaller than those of the corresponding AGNRs. Our results show that the origin of band gap for BNCNRs with armchair shaped edges arises from both quantum confinement effect of the edges. These results similar to thecase of AGNRs. These properties of hybrid BN/C nano-ribbon structure may offer suitable bandgap to develop nnanoscale electronics and solar cell beyond individual GNRs and BNNRs.

  • PDF

열충격 시험 후 태양전지 파괴 모드에 따른 전기적 특성변화 (Electric Degradation of Failure Mode of Solar Cell by Thermal Shock Test)

  • 강민수;전유재;신영의
    • 에너지공학
    • /
    • 제22권4호
    • /
    • pp.327-332
    • /
    • 2013
  • 일본 연구에서는 열충격 시험을 통한 태양전지의 파괴모드에 따른 전기적 특성을 분석하였다. 시편은 Photovoltaic Module을 만들기 전 3 line Ribbon을 Tabbing한 단결정 Solar Cell을 제작하였다. 열충격 시험 Test 1의 온도조건은 저온 $-40^{\circ}C$, 고온 $85^{\circ}C$, Test 2는 저온 $-40^{\circ}C$, 고온 $120^{\circ}C$에서 Ramping Time을 포함하여 각각 15분씩, 총 30분을 1사이클로 500사이클을 각각의 조건으로 수행하였다. 열충격 시험 후 Test 1에서는 4.0%의 효율 감소율과 1.5%의 Fill Factor 감소율을 확인하였으며, Test 2에서는 24.5%의 효율 감소율과 11.8%의 Fill Factor 감소율을 확인하였다. EL(Electroluminescence)촬영 및 단면을 분석한 결과, Test 1과 Test 2 시편 모두 Cell 표면 및 내부에서의 Crack이 발견되었다. 하지만, Test 2의 시험이 Test 1보다 가혹한 온도조건의 시험으로 인해 Test 1에서 나타나지 않았던, Cell 파괴를 Test 2에서 확인하였다. 결국, Test 1에서 효율의 직접적인 감소 원인은 Cell 내부에서의 Crack이며, Test 2에서는 Cell 내부에서의 Crack 및 Cell 파괴로 인한 Cell 자체의 성능저하로 효율이 크게 감소한다는 것을 본 실험을 통하여 규명하였다.