• Title/Summary/Keyword: Solar Radiation Analysis

Search Result 514, Processing Time 0.029 seconds

Characteristic Evaluation of Bifacial Solar Module Power Plant Using Back Sheet as Reflective (백시트를 반사재로 이용한 양면태양광 발전시스템 특성평가)

  • Kim, Hyun Jun;Jho, Min Jae;Cha, Hyang Woo;Kim, Kwang Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.112-116
    • /
    • 2022
  • The demand for a rear reflective material is continuing according to the expansion of the bifacial soar module and the effect on the re-reflection of the ground using a back sheet that is not used due to the increase in the supply of the bifacial solar module was confirmed. For analysis, a bifacial solar module with an output of 445W was connected to a single inverter of 49.84kW, and analysis of each two inverters was carried out. In the analysis of the results, it was confirmed that the generation amount increased by 5.25% compared to the case where the back sheet reflective film was not installed and it was confirmed that the increase in the generation amount was the noon time when strong solar radiation was irradiated, not the time of sunrise and sunset.

HAUSAT-2 SPACE RADIATION ENVIRONMENT AND EFFECTS ANALYSIS (HAUSAT-2 우주방사능 환경과 영향 분석)

  • Jung Ji-wan;Chang Young-Keun
    • Bulletin of the Korean Space Science Society
    • /
    • 2005.04a
    • /
    • pp.143-147
    • /
    • 2005
  • This paper describes the analysis of radiation environment and effects. TID(Total ionizing Dose) and SEE(Single Event Effects) analysis are implemented. The HAUSAT-2 is a 25kg class nanosatellite which is operated at sun-synchronous orbit at an altitude 650km. Trapped proton and Electron, Solar Proton, Galactic Cosmic Ray models are considered to HAUSAT-2 radiation environment model. Total Dose-depth curve provides TID degree and components are verified by DMBP method and Sectoring analysis. SEE are analysed with Radiation Test Report. Existing Radiation Test Reports are use to SEE analysis of HAUSAT-2.

  • PDF

Numerical investigation of natural convection heat loss in solar receiver for dish concentrating system (접시형 태양열 집광시스템용 흡수기의 자연대류 열손실 수치해석 연구)

  • Kang, Myeong-Cheol;Kang, Yong-Heack;Kim, Jong-Kyu;Kim, Jin-Soo;Yoo, Seong-Yeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.680-683
    • /
    • 2007
  • In dish concentrating system, natural convection heat loss occurs in cavity receiver. Heat loss mechanisms of conduction, convection, and radiation can reduce the system efficiency. To obtain the high efficiency, the receiver is to absorb the maximum of solar energy and transfer to the working fluid with maximum of heat losses. The convection heat loss is an important factor to determine the system performance. Numerical analysis of the convection heat loss of receiver was carried out for varing inclinaton angle from 0$^{\cdot}$ to 70$^{\cdot}$ with temperature range from 400$^{\cdot}C$ to 600$^{\cdot}C$ using the commercial software package, Fluent 6.0. The result of numerical analysis was comparable with convection heat loss model of solar receiver.

  • PDF

Performance Analysis of Heat Transfer Characteristic and Hydrogen Product for Dish Type Solar Chemical Reactor (접시형 고온 태양열 화학 반응기의 열전달 및 수소생산 성능 분석)

  • Yang, Seung-Bok;Go, Man-Seok;O, Sang-Jun;Seo, Tae-Beom
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.774-779
    • /
    • 2009
  • The purpose of this research is to develop the high performance of solar chemical reactor for producing hydrogen by methane reforming reaction with steam. Two shape of chemical reactor is suggested: first type is filled with porous material and second type is spiral type. These reactors is installed on the dish-type thermal system of Inha University, Inha Dish-1. Performance analysis of these two reactors is conducted from getting methane conversion.

  • PDF

The Performance and Efficiency Analysis of PVT system : A Review (선행 연구된 태양광열 복합 시스템의 문헌 검토를 통한 성능 및 효율분석)

  • Euh, Seung-Hee;Kim, Dae-Hyun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.250-255
    • /
    • 2011
  • A Photovoltaic/Thermal(PVT) solar system consists of PV module and thermal absorber plate which convert the absorbed solar radiation into electricity and heat. Meaningful researches and development (R&D) on the PVT technologies have been performed since the 1970s. This paper presents a review of the previous works covering the various types of PVT and their performance analysis in terms of electrical and thermal efficiency. This review compares electrical and thermal efficiency of the different types of PVT collectors and analyzes the parameters affecting PVT performance. Based on the literature review, box charmel type PVT with unglazed, or flat plate PVT with glazed have the highest efficiency among them. From the literature review, R&D should be carried out aiming at improving their overall electrical and thermal efficiency and cutting down the cost, making them more competitive in the energy consumption market.

  • PDF

Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation (파사드 일체형 자연순환 태양열온수기 유동해석)

  • Baek, Nam-Choon;Lee, Wang-Je;Lim, Hee-Won;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

A Study on the Applicability of Double-Sided Vertical Photovoltaic Panels Based on Energy Productivity Analysis (에너지 생산성 분석 기반 양면발전형 수직 태양전지의 활용 가능성 탐색)

  • Seung-Ju Choe;Seung-Hoon Han
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.84-97
    • /
    • 2023
  • This study aimed to investigate the feasibility and potential applications of utilizing bifacial photovoltaic (PV) panels from an architectural perspective. It also aimed to establish a foundational dataset for installation and operational guidelines for bifacial PV panels through a comparative analysis of energy production performance with single PV panels. The research encompassed several key steps, including a comprehensive literature review, calculation of solar surface radiation values, development of datasets for bifacial and single PV energy production, and a performance comparison between both approaches. The results of the study show that bifacial PV panels exhibit optimized energy production capabilities within the range of 40 to 80 degrees, contingent upon the specific installation location. Consequently, it is recommended that the installation of bifacial PV panels in Korea should primarily focus on southwest-to-west orientation. Furthermore, it was concluded that bifacial PV panels could contribute an equivalent or even superior level of energy production compared to single PV panels, even if their performance exhibited a marginally lower efficiency of 2% to 5% with an 18% power generation efficiency.

Analysis and Calculation of Hourly Surface Temperature Based on Typical Meterorological Data for Major Cities in Korea (국내 주요도시의 표준기상자료를 이용한 시간당 표면온도 산출 및 분석)

  • Lee, Kwan-Ho;Cho, Hyun-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.123-128
    • /
    • 2012
  • Computer simulation of buildings and solar energy systems is being used increasingly in energy assessments and design. The purpose of our work is to predict the surface temperature on inclined surfaces based on ISO-TRY typical weather data. To reach this goal, three studies were performed. They consisted of quantifying the accuracy of various well-known three models. The first type of models calculated diffuse horizontal irradiations from global ones and the second type models computed global irradiations on inclined planes from diffuse and global components on a horizontal surface. The third type of model calculated long-wave radiation and surface temperature from ISO-TRY typical weather data. The proposed model can provide an alternative to building designers in estimating the surface temperature and solar irradiation on inclined surfaces where only the typical meteorological data are available.

Analysis of Energy Concentration Characteristics of Heliostat used in 200kW Tower Type Solar Thermal Power Plant (200kW 탑형 태양열발전시스템에서 사용되는 Heliostat의 집열특성 분석)

  • Park, Young-Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.80-88
    • /
    • 2011
  • Heliostat in the tower type solar thermal power plant is a sun tracking mirror system to reflect the solar energy to the receiver and the optical performance of it affects to the efficiency of whole power plant most significantly. Thus a solid understanding of heliostat's energy concentration characteristics is the most important step in designing of the heliostat field and the whole power plant. The work presented here is the analysis of energy concentration characteristics of heliostat used in 200kW solar thermal power plant, where the receiver located at 43m high in tower has $2{\times}2$m rectangular shape. The heliostat reflective surface is formed by 4 of $1{\times}1$m flat plate mirror facet and the mirror facet is mounted on the spherical frame. The direct normal incident radiation models in vernal equinox, summer solstice, autumnal equinox and winter solstice are first derived from the actually measured data. Then the intercept ratio, heat flux distribution and total energy collected at the receiver for the heliostats located in the various places of the heliostat field are investigated. Finally the effect of mirror facet installation error on the optical performance of the heliostat is analyzed.

Impact of Physical and Vegetation Patterns on Parks Environment: A Case Study of Gusan Neighborhood Park, South Korea (도심산림녹지의 식생 및 물리적 구조에 따른 숲 내부 미기상 변화 연구)

  • Kim, Jeong-Ho;Choi, Won-Jun;Lee, Sang-Hoon;Lee, Myung-Hun;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.425-435
    • /
    • 2020
  • This study aims to investigate the impact of the physical structure, such as altitude, slope gradient, slope direction, and topographical structure, and the vegetation pattern, such as existing vegetation, diameter of breast height (DBH), and crown density, on climate. The analysis results showed the significant difference in relative humidity, wind speed, and solar radiation at varying altitudes, the significant difference in all climate factors except for the wind speed at varying slope gradient, and significant difference in temperature and relative humanity at varying slope direction. The topographic structures were divided into valleys, slopes, and ridges. They were found to differ in relative humidity. However, the differences between constant trends and types were found to be insignificant concerning temperature, wind speed, and solar radiation. Significant differences in temperature, relative humidity, and wind speed were recorded with changing existing vegetation. The DBH showed a significant difference in temperature, wind speed, and solar radiation. The crown density showed a significant difference in temperature and solar radiation. The result of the relationship analysis for the analysis of the effect of vegetation pattern and physical structure on the meteorological environment showed that temperature was affected by slope gradient, slope direction, DBH, and crown density. The relative humidity was correlated with the altitude, slope gradient, slope direction, and topological structure in physical structure and the existing vegetation and crow density in vegetation pattern. The wind speed was correlated with the altitude, existing vegetation, and DHB, and the solar radiation was correlated with the slope gradient, DHG, and crown density. The crown density was the most overall significant factor in temperature, relative humidity, and solar radiation, followed by the slope gradient. DBH was also found to be highly correlated with temperature and solar radiation and significantly correlated with wind speed, but there was no statistically significant correlation with relative humidity.