• 제목/요약/키워드: Soil resistivity

검색결과 259건 처리시간 0.035초

대형 봉상 접지전극의 길이에 따른 뇌 임펄스 특성 (Lightning impulse characteristics of large-scale ground rods with different length)

  • 이복희;장근철;엄주홍;김병근;정동철;길형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.233-235
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is significantly increased. This paper presents how the impulse current works on the long vertical ground rods with a different length. As a result, it can be estimated what the waveform is composed of and how the GPR is affected by the rate of current change.

  • PDF

CDEGS를 이용한 가로등의 접지특성에 관한 연구 (A Study on the Grounding Characteristics of a Street Light using CDEGS)

  • 이재화;장덕관;전재관;노영수;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.214-216
    • /
    • 2003
  • Since it is frequently reported, nowadays, that a variety of accidents happen in association with a street light, it is urgently demanded to take necessary measures to cope with such situation. In this aspect, it is important to study the grounding characteristics of a street light because most of the accidents are related to grounding. In this paper, therefore, the grounding characteristics of a street light have been investigated based on layers by using CDEGS. As a result of simulation, the soil resistivity turns out to be extremely important determining the characteristics of a grounding system.

  • PDF

교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구 (Corrosion Rate of Buried Pipeline by Induced Alternating Current)

  • 송홍석;김영근;이성민;고영태;박용수
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2001년도 추계학술발표회 논문집
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

1차원 및 2차원 대지비저항 측정에 의한 접지설계 비교 (A Comparison study on Grounding design by 1-Dimensional and Soil 2-Dimensional Electrical Resistivity Subvey)

  • 한성구;조대훈;정철희;류청희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2188_2190
    • /
    • 2009
  • 대지비저항의 측정 분석에 주로 사용되는 4-점 Wenner 전극법이며 1차원 측정법을 이용한다. 1차원 측정방법은 방법이 간편하며 경제적이지만, 측정방법이 기본적으로 특정한 대지구조를 갖는다고 가정하고 분석하므로 실제의 대지구조와 측정하여 분석한 대지구조 모델이 차이를 갖게 되고, 이로인해 접지설계와 실제시공 결과 사이에 오차가 발생하게 된다. 본 연구에서는 1차원 및 2차원 측정법을 이용하여 분석된 대지구조모델를 이용하여 접지시스템 설계를 수행하였고, 이 결과를 실제현장에 시공하여 각각의 특성을 비교 분석하였다.

  • PDF

뇌격전류에 의한 수평접지극의 전위상승 계산 (Calculation of Electric Potential Rise of Horizontal Grounding Electrode Caused by Lightning Stroke Currents)

  • 이복희;조성철
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.81-86
    • /
    • 2013
  • An electric potential rise of the grounding electrode developed by the lightning stroke currents should be calculated for the purpose of effective protection of electrical and electronic equipment. In this paper, the electromagnetic model was applied to calculate the harmonic impedance of grounding electrode. Also the empirical equation related to the permittivity and resistivity of soil was used. The lightning current waveforms, which are expressed by the Heidler's equation, were used in order to calculate accurately transient electric potential rises. The transient voltage was obtained by using the simulated harmonic impedance and the lightning current in frequency domain. Finally, the transient voltages of horizontal grounding electrode(10m) under lightning stroke currents were calculated by IFFT(Inverse Fast Fourier Transform).

Wenner 4측정 데이터를 이용한 다층구조 대지의 파라미터 결정 (Estimation of Multilayer Earth Model Parameter from Wenner Four-probe Test Data)

  • 김호찬;부창진;김세호;오성보;고영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1781-1782
    • /
    • 2006
  • In this paper, a methodology has been proposed according to which, after carrying out a set of soil's resistivity measurements using Wenner Four-probe data, one can compute the parameters of the multilayer earth structure using a genetic algorithm(GA). The results provided by the GA constitute the indispensable data that can be used in circuital or field simulations of grounding systems. The methodology allows to proceed toward a very efficient simulation of the grounding system and an accurate calculation of potential on the ground's surface.

  • PDF

지중송전관로 유동화 뒷채움재의 시공성 평가 (Evaluation of Construction Applicability for Slurry Backfill Materials of Underground Power Cable)

  • 김대홍;조화경;오기대;이대수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1068-1075
    • /
    • 2006
  • Flow-able backfill is known as soil-cement slurry, void fill, and controlled low-strength material (CLSM). The benefits of CLSM include reduced equipment costs, faster construction, re-excavation in the future, and the ability to place material in confined spaces such as narrow parts nearly impossible for compaction or perimeter of underground power cables. A review of some recent full-scale tests carried out by KEPRI on slurry backfill materials for application in underground power cable was presented. Based on this research, applicability was assessed and compare to results of laboratory tests for improved slurry materials with optimal mixture contents.

  • PDF

전국의 암석, 토양층에 대한 토양비저항 조사 (Investigation of Resistivity for Rock and Soil in South Korea)

  • 이현구;배정효;하태현;김대경;최상봉;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1354-1356
    • /
    • 1999
  • 토양에 대한 연구는 오래 전부터 시작되었으며, 여러 가지 방법으로 토양의 특성을 조사하고 이를 적용하기 위한 분류법이 제안되어 왔다. 국내에서도 해방 전부터 토양에 대한 연구가 시작되었으나, 농업에 이용하기 위한 연구가 대부분을 차지하고 있으며 각각의 연구결과는 물리, 화학적으로 정량화 되어 있지 않기 때문에 환경에 따른 특성의 변화를 예측할 수 없다. 또한 접지설계 등의 전기관련 분야에 활용하기 위한 연구는 전무한 실정이다. 본 논문에서는 토양의 개념, 생성인자, 분류 및 전기적 특성 등의 개요를 알아보고, 지질학 및 지구물리학적인 방법을 통하여 국내의 암석 및 토양에 대한 비저항의 물리적, 화학적 특성을 측정하기 위한 방법을 조사하였다. 이를 바탕으로 암석과 토양에 대한 개략적인 토양비 저항도를 작성하여 접지설계 및 지하매설 금속물의 방식 설계 등에 활용하기 위한 토대를 마련하고자 한다.

  • PDF

스마트 물리탐사 기법을 이용한 토량환산계수 산정 (Estimation of Soil Volume Conversion Factor using Smart Geophysical Exploration Method)

  • 류희환;진규남;박성욱;조계춘
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.170-173
    • /
    • 2011
  • 국내 풍화지반의 토량환산계수를 정확하고 합리적으로 추정하는 것은 공사의 성패에 있어 매우 중요한 사항이다. 하지만 현업에서는 풍화지반의 풍화도를 정량화하는 것이 어렵고, 토량환산계수를 적용 시 외국의 기준을 사용하는 경우가 빈번하다. 뿐만 아니라, 국내 풍화지반의 토량환산계수에 관한 연구는 아직 미비하여, 끊임없이 토량환산계수의 정확성 및 사용성에 대해 문제 제기가 있어 왔다. 이에 본 연구에서는 TEPS (Tunnel Electrical resistivity Prospecting System)를 이용하여 화강암의 풍화 정도와 전기비저항의 상관관계를 도출하고 풍화지반 내 흙이 차지하는 비율(S/W 비)을 전기비저항과 개괄적으로 상관관계를 맺어 전기비저항을 이용하여 토량환산계수를 산정하는 방법을 제안하였다. 현장 관리자가 풍화지반에서 쉽게 토량환산계수 및 토공량에 관한 정보를 획득할 수 있도록 풍화지반 토공관리프로그램(WEMP)을 개발하고 토량환산계수 측정시스템을 설계하였다.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.