• 제목/요약/키워드: Soil resistivity

검색결과 261건 처리시간 0.032초

지하주입 물질 거동 규명을 위한 4차원 전기비저항 영상화 (Application of 4-D resistivity imaging technique to visualize the migration of injected materials in subsurface)

  • 김정호;이명종
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 특별 심포지엄 논문집
    • /
    • pp.31-42
    • /
    • 2007
  • Dc resistivity monitoring has been increasingly used in order to understand the changes of subsurface conditions in terms of conductivity. The commonly adopted interpretation approach which separately inverts time-lapse data may generate inversion artifacts due to measurement error. Eventually the contaminated error amplifies the artifacts when reconstructing the difference images to quantitatively estimate the change of ground condition. In order to alleviate the problems, we defined the subsurface structure as four dimensional (4-D) space-time model and developed 4-D inversion algorithm which can calculate the reasonable subsurface structure continuously changing in time even when the material properties change during data measurements. In this paper, we discussed two case histories of resistivity monitoring to study the ground condition change when the properties of the subsurface material were artificially altered by injecting conductive materials into the ground: (1) dye tracer experiment to study the applicability of electrical resistivity tomography to monitoring of water movement in soil profile and (2) the evaluation of cement grouting performed to reinforce the ground. Through these two case histories, we demonstrated that the 4-D resistivity imaging technique is very powerful to precisely delineate the change of ground condition. Particularly owing to the 4-D inversion algorithm, we were able to reconstruct the history of the change of subsurface material property.

  • PDF

원심모형실험을 위한 전기비저항 탐사 시스템 구축 (Development of Electrical Resistivity Survey System for Geotechnical Centrifuge Modeling)

  • 조형익;방은석;이명종;추연욱;김동수
    • 한국지반공학회논문집
    • /
    • 제30권10호
    • /
    • pp.19-31
    • /
    • 2014
  • 원심모형실험 중 지반모형의 상태 변화를 입체적으로 파악하기 위한 방법으로 전기비저항 탐사를 시도하였다. 탐사 시스템은 현장에서 널리 사용되는 검증된 상용 장비를 바탕으로 하였다. 컴퓨터 원격 조정으로 실험 시설 내에 설치된 탐사 장비를 통제하고 실시간 해석을 통해 결과 영상을 원심 모형실험 중에 바로 확인할 수 있도록 구성하였다. 구축된 탐사 시스템의 안정적 구동 여부를 점검하기 위해 불포화상태로 조성된 모형 지반 상단에 염수를 떨어뜨려 지반 내부로 이동하게 하고 전기비저항 탐사를 수행하였다. 10g로 원심력을 가한 상태에서 실험을 수행하고 시간대별 염수 침투상황을 전기비저항 영상으로 확인하였으며 일반 중력장에서 동일하게 실험한 결과와 비교하였다. 실험 종료 뒤 모형지반 수직 절단면을 이용하여 직접 측정한 전기비저항 값과 획득한 영상을 비교함으로써 신뢰성을 검증하였다.

전기비저항과 유도분극을 활용한 TBM 터널 굴착면 전방 복합지반 예측 기법 (Forward probing utilizing electrical resistivity and induced polarization for predicting mixed-ground ahead of TBM tunnel face)

  • 류진우;박진호;이성원;이인모;김병규
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.55-72
    • /
    • 2018
  • 본 연구에서는 시공 중 TBM 터널에서 전기비저항과 유도분극(induced polarization, IP) 탐사를 활용하여 굴착면 전방의 복합지반(mixed-ground)을 예측하기 위한 방안을 제시하였다. TBM이 토사를 굴진하며, 굴착면 전방에서 상부 토사지반과 하부 암반으로 이루어진 복합지반을 조우하는 과정과 동시에 전기비저항과 유도분극에 의한 충전성(chargeability)을 측정하며 굴진하는 과정을 실내실험으로 모사하였다. 전기비저항과 충전성의 측정은 4전극을 이용하였으며, 복합지반을 효과적으로 예측하기 위하여 2개의 전극은 굴착면에, 나머지 2개의 전극은 조립된 세그먼트에 설치됨을 가정하였다. 실험 결과, TBM이 토사 굴진 중 토사-암반의 복합지반으로 진입할 경우 전기비저항과 충전성이 모두 증가하였다. 또한, TBM이 굴착면 전방에서 복합지반을 조우할 것임을 예측하기 위하여 굴착면의 전극 2개, 세그먼트의 전극 2개를 활용한 탐사와 동시에 굴착면 4전극 탐사를 수행하면 더욱 효과적인 예측이 가능함을 확인하였다.

폐기물매립지 주변의 오염물질 분포 및 이동 특성 (Characteristics of Distribution and Potential Route of Contaminants at Waste Disposal Site)

  • 박성원;황세호;이평구;박인화;신성천;이상규
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.144-148
    • /
    • 2001
  • A geophysical and geochemical study was performed to verify the depth of landfill as well as the horizontal/vertical distribution of leachate at the landfill site located in Gongju. The electrical resistivity, with dipole-dipole array and dipole spacing of 5m, was applied along the nine survey lines and electromagnetic induction survey was conducted along the perimeter traverse surrounding the landfill. Cations, anions and stable isotope ($\delta$D and $\delta$$^{18}$ O) analyses were performed on about 63 water and leachate samples collected in dry and rainy seasons at 31 sites. The result of electromagnetic induction survey make it possible to derive the potential route of leachate in the past or present. The imaging of processed resistivity field data show that the possible route of leachate doesn't exist except the survey line 7. The weak zone traversing the landfill, however, is revealed by the electrical resistivity imaging, which may be the potential route of leachate toward the deep ground. The geochemical data agree well with geophysical data for deducing possible route of leachate of the site.

  • PDF

ERT를 이용한 전력설비용 대지모델 영상복원 (Grounding model Image Reconstruction for Electric Power Facilities Using ERT)

  • 부창진;최승준;정광자;고봉운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1751_1752
    • /
    • 2009
  • The accurate measurement of soil resistivity and earthing system resistance is fundamental to electrical safety. However, geological and meterological factors can have a considerable effect on the accuracy of conventional measurements and the validity of the measurement methods. This paper presents optimization method of dc resistivity data acquisition system using ERT.

  • PDF

Image Reconstruction of Subspace Object Using Electrical Resistance Tomography

  • Boo, Chang-Jin;Kim, Ho-Chan;Lee, Yoon-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2480-2484
    • /
    • 2005
  • Electrical resistance tomograpy (ERT) maps resistivity values of the soil subsurface and characterizes buried objects. The characterization includes location, size, and resistivity of buried objects. In this paper, truncated least squares (TLS) is presented for the solution of the ERT image reconstruction. Results of numerical experiments in ERT solved by the TLS approach is presented and compared to that obtained by the Gauss-Newton method.

  • PDF

물리탐사자료의 GIS 복합처리에 의한 천부지질구조 해석 (Interpretation of shallow geological structure by applying GIS to geophysical data)

  • 송성호;정형재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.123-126
    • /
    • 1998
  • We have conducted surface electrical resistivity surveys along with the electrical logging at Bookil-Myun, Chungwon-Goon, Choongchungbuk-Do to determine the depths of basement and water table, and for the purpose of preparing the basic input data for hydrogeologic model combined with GIS. A twenty lines of dipole-dipole array survey and a twenty-five stations of resistivity sounding were performed and ten holes were employed for electrical logging to cross check the surface data. A combined interpretation gave the quantitative information of the shallow geologic structure over the area and we constructed layers using the grid analysis of Arc/info. The constructed layers were turned out to be similar to the geologic structure confirmed from the drilling data and we concluded that the methodology adopted in this study would be applicable to hydrogeologic model setup as a tool of providing the basic input data.

  • PDF

붕괴가 발생한 급경사지의 현장 투수계수 (Permeability Coefficient of Unsaturated Soil in Steep Slope Failure Area)

  • 최은경;김성욱;박덕근;오정림
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.921-926
    • /
    • 2010
  • To examine saturation characteristics of an unsaturated soil in the steep slope area with collapse, it separated dry season from rainy season and measured water content and permeability, and measured permeability by using a tension infiltrometer in the site. In addition, it conducted electrical resistivity survey to look into thickness of ground and geological structure of underground. The collapsed slope increased depth of weathered zone compared to upper slope, and there electrical resistivity anomalous zone caused by the filtrated underground water was observed. The permeability of the collapsed area was observed high compared to upper and lower slopes of retarding basin without collapse, and the permeability measured by dividing the dry season and rainy season was measured high in case of dry season.

  • PDF

충북 초정지역의 지하수환경 조사를 위한 지표지구물리탐사 (Geophysical Surveys for Investigating the Groundwater Environment of the Chojeong, Chungbuk)

  • 김지수;한수형;김경호;신재우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.103-106
    • /
    • 2000
  • Geophysical data sets from the Chojeong area in the Chungbuk-Do are compositely studied in terms of multi-attribute interpretation for the subsurface mapping of shallow fracture zones, associated with groundwater reservoir. Utilizing a GIS software, the attribute data are implemented to a database; a lineament from the satellite image, electrical resistivities and its standard deviation, radioactivity, seismic velocity, bedrock depth from exploration data. In an attempt to interpret 1-D electrical sounding data in 2-D and 3-D views, 2-D resistivities structures are firstly made by interpolating 1-D plots. Reconstruction of a resistivity volume is found to be an effective scheme for subsurface mapping of shallow fracture zones. Shallow fracture zones in the southeastern part of the study area are commonly correlated in the various exploration data.

  • PDF

환경물리탐사 기법을 이용한 유류오염 주유소 부지 특성 조사

  • 김창렬;고경석;김정호;박삼규;손정술;정지민
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.429-432
    • /
    • 2005
  • Geophysical investigations, as a non-invasive method, were conducted at the former gas station site contaminated with fuel hydrocarbons. GPR (Ground Penetrating Radar) survey was performed to locate buried objects such as USTs (Underground Storage Tanks) and fuel pipes which might serve as a origin of the site contamination. Additional GPR investigation and a resistivity survey were conducted to map water table and to characterize shallow geologic structures of the site. The results of the study have shown that seven USTs including one unknown UST and buried fuel pipes are present, and that the groundwater elevation varies with topography from approximately 1.5 to 3m below the surface and the water table is located in the residual soils above the bedrock in the site. The results also show that the geophysical methods can be a very useful tool for the characterization of the contaminated site.

  • PDF