• Title/Summary/Keyword: Soil reinforced wall

Search Result 209, Processing Time 0.024 seconds

A Study on the Application of Soil-Reinforced Retaining Wall for Excavation Slope (절토사면에서 보강토 옹벽의 적용성 연구)

  • Byun, Yoseph;Wrryu, Woongryeal;Lee, Dongho;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.2
    • /
    • pp.53-60
    • /
    • 2010
  • Considering environmental issues and lack of space, it is a necessity to minimize the amount of excavation. Various types of excavation methods are being used in practice. This study proposes a reasonable method for estimating the earth pressure acting on a reinforced wall in front of a excavated slope. The measured data in the field and numerical analyses were used. Results of the study shows that the earth pressure acting on the excavated wall is less than that estimated by Rankine's equations. It was shown that when the excavated slope is used with the reinforced wall, the pressures acting on the reinforced wall can be greatly reduced.

An Experimental Study on Reinforcing Effects for Soil Structures Reinforced by Nail with an Anchor Shape (앵카형태의 지반네일로 보강된 흙구조물의 보강효과에 관한 실험적 연구)

  • 김준석;이상덕;이승래
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.2
    • /
    • pp.103-111
    • /
    • 2001
  • 지반네일 보강방법은 이론적 뒷받침과 함께 경험적인 작업을 기초로 발전되어 왔으며, 연구 결과를 바탕으로 현장적용이 활발하게 이루어지고 있다. 본 연구에서는 소일 네일로 보강된 토체의 안정성에 중요한 요소인 소일네일의 인발저항력을 높이기 위하여 네일의 끝 부분에 앵커와 같은 구근이 형성된 네일로 보강된 토체의 파괴거동을 이해하기 위하여 비교적 큰 규모의 실험을 실시하였다. 토체의 변위, 네일의 축변형률, 네일의 축하중, 토체내부의 토압 등에 관한 자료를 얻었으며 이러한 자료들을 분석하였다. 또한 같은 조건에서 일반적인 형태의 네일로 실험된 결과와 비교분석을 실시하였다.

  • PDF

Workability Characteristics of Fiber Mixed Soil (섬유 보강 혼합토의 워커빌리티 특성)

  • Song, Gyoo Bog;Lee, Sang Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.1
    • /
    • pp.53-59
    • /
    • 2016
  • This study was conducted by the slump test and the consistency test of the fiber mixed soil which is soil reinforced with fiber as a reinforced material to investigate and estimate the difficulty degree of work and the proper water content. So I would like to present the fundamental data that establishes the work standard of the fiber mixed soil. In conclusion, in this study the slump value of the fiber mixed soil increases over-all according to the increase of the water content although it has a little difference of the increase range and it is smaller than one of the soil. It is estimated that the aggregating and throwing work of the fiber mixed soil would be fine when it has the about 25 % water content and the wall and floor plastering work is the about 30 % ~ 35 % and the flowing and pouring work is the about 40 % water content as well as the mold compacting work is the about 20 %. There is no decreasing of the workability when the soil is reinforced by the fiber because the workability characteristics of the fiber mixed soil is similar to the one of the soil. Therefore, It is estimated that using the fiber as a reinforced material of soil would be appropriate for the construction.

Load Carrying Capacity of Back-to-Back Reinforced Soil Walls (Back-to-Back 보강토 옹벽의 하중지지 특성)

  • Yoo, Chung-Sik;Kim, Sun-Bin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.12
    • /
    • pp.41-52
    • /
    • 2008
  • This paper concerns the load carrying capacity of back-to-back reinforced soil wall for use in roadway and railway construction. Two test conditions, designed with due consideration of the FHW A design guideline, were first developed and a number of cases having different reinforcement lengths were tested under a surchage loading until failure. The results indicated that for cases in which two sides of reinforcements do not overlap, the wall behavior was similar to those of single wall. For cases in which the reinforcements overlap each other, on the other hand, the load carrying capacity of the wall significantly decreased when reinforced with reinforcement layers having lengths less than 50% of the wall height.

Comparison of numerical and analytical solutions for reinforced soil wall shaking table tests

  • Zarnani, Saman;El-Emam, Magdi M.;Bathurst, Richard J.
    • Geomechanics and Engineering
    • /
    • v.3 no.4
    • /
    • pp.291-321
    • /
    • 2011
  • The paper describes a simple numerical FLAC model that was developed to simulate the dynamic response of two instrumented reduced-scale model reinforced soil walls constructed on a 1-g shaking table. The models were 1 m high by 1.4 m wide by 2.4 m long and were constructed with a uniform size sand backfill, a polymeric geogrid reinforcement material with appropriately scaled stiffness, and a structural full-height rigid panel facing. The wall toe was constructed to simulate a perfectly hinged toe (i.e. toe allowed to rotate only) in one model and an idealized sliding toe (i.e. toe allowed to rotate and slide horizontally) in the other. Physical and numerical models were subjected to the same stepped amplitude sinusoidal base acceleration record. The material properties of the component materials (e.g. backfill and reinforcement) were determined from independent laboratory testing (reinforcement) and by back-fitting results of a numerical FLAC model for direct shear box testing to the corresponding physical test results. A simple elastic-plastic model with Mohr-Coulomb failure criterion for the sand was judged to give satisfactory agreement with measured wall results. The numerical results are also compared to closed-form solutions for reinforcement loads. In most cases predicted and closed-form solutions fall within the accuracy of measured loads based on ${\pm}1$ standard deviation applied to physical measurements. The paper summarizes important lessons learned and implications to the seismic design and performance of geosynthetic reinforced soil walls.

Analysis of the Segmental Reinforced Retaining Wall Behavior by Field Monitoring (현장계측을 통한 블럭식 보강토 옹벽의 거동분석)

  • Shin, Eun Chul;Lee, Chang-Seup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.3-15
    • /
    • 2004
  • Geogrid reinforced soil structures with segmental block facing have been increased since 1990's, because of the convenience of installation and the flexible appearance. In this paper, the behavior of the segmental reinforced retaining wall was analysed with the results of field monitoring. The height and length of reinforced wall are 12m and 25m, respectively. The field measurement equipments are horizontal and vertical earth pressure cells, settlement plate, strain gauge, inclinometer, and displacement pin. Based on the field monitoring, the horizontal earth pressure was approximately 0.3times higher than that of the theoretical method and the maximum tensile strength of reinforcement was 26.2kN/m. The displacement of facing wall was 23mm at the point of 7.1m height of the wall and toward the wall facing. The results of the study indicate that the segmental reinforced retaining wall is in a stable condition because of good compaction & reinforcement effects, and long period of construction time. Finally, the computer program of SRWall is very useful tool to design the segmental reinforced retaining wall.

  • PDF

Shear strength characteristics of reinforced decomposed granite soil by uncomsolidated-undrained triaxial compression test (비압밀비배수 삼축압축시험에 의한 보강화강풍화토의 전단강도 특성)

  • Cho, Yong-Seong;Goo, Ho-Bon;Park, Inn-Joon;Kim, You-Seong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.103-110
    • /
    • 2006
  • When enforced earth is used for the retain wall and four walls, the most important thing would be how to maximize the land utilization. Accordingly, in case of enforced earth, we pile up the minimal height of earth$(20\sim30cm)$ and harden the earth using a static dynamic hardening machine. In this paper, we tried to analyze and. compare the stress transformation characteristics of reinforced weathered granite soil. with geosynthetics when repetitive load is added to the enforced earth structure and when static load is added. The purposes of the study are as follows; 1) To compare and analyze non reinforced weathered granite soil and reinforced weathered granite. soil by executing a unconsolidated-undrained triaxial compression tests. 2) To identify the strength characteristics of weathered granite soil reinforced with geotextile due to the repetitive dynamic loads through comparison of the stress due to the static load and the repetitive dynamic loads.

  • PDF

Case Study of Environmental Segmental Retaining Wall(SRW) Using Greenstone Block (환경친화적 블록식 보강토옹벽의 설계 및 시공사례연구)

  • Han, Jung-Geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.6
    • /
    • pp.19-28
    • /
    • 2004
  • Segmental Retaining Wall(SRW) has been variously applying in Civil and Architecture construction. Recently, the application of environmental element in all type's structures came to essential requirement, and the construction cases of retaining wall using reinforced soil and block are more increased than the past. But, this trend more widely was spread environmental element as landscape work for the backside of reinforced retaining wall as well as block itself. New environmental block, Greenstone Block, developed to apply of this tendency. The retaining wall system using Greenstone can be environmental constructing at both block itself and backside of retaining wall. The material tests, the axial compressive strength test of block and bending test of fiber-pipe, exercised to design and construction of vertical SRW, which were satisfied NCMA standard. Through this procedure, Rewall (ver 1.0) was developed, which can be automation design of SRW including internal stability, external stability and local stability. And these can be considered setback of retaining wall, as well the examples of vertical retaining wall using block presented to satisfying the follows; strength of reinforced geotextile, height of retaining wall, surcharge, types of backfill and groundwater level etc. Many problems investigated on after or before of construction were due to local failure, insufficiency of bearing capacity and groundwater level. Especially, the local failure was many occurred to during compaction or after construction, and the cases of SRW construction is similar to the results of model test on vertical SRW.

Effect of Stability of Reinforced Wall within Drain Layers in the Rainfall (강우시 보강토 내부 배수가 보강토 옹벽의 안정성에 미치는 영향)

  • Sin, Chun-won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.165-174
    • /
    • 2017
  • There are natural disasters caused by abnormal climate in the world. In particular, there are frequent disasters such as floods and landslides caused by rainfall in summer. Rainfall will have a major impact on the stability of a retaining wall. If drainage during rainfall activities within the retaining wall is not made properly, permeated water brings a significant increase in pore pressure inside of the backfill soil and reduces the shear strength of the soil. Therefore, research how to install the drainage layers to reduce the infiltrated water inside of the backfill soil is very necessary. In this study, we performed a numerical modeling to find the optimum installation conditions of the location and number of drainage layer related to stability of the reinforced retaining wall during rainfall installed geosynthetics.

Long Term Behaviors of Geosynthetics Reinforced Soil Walls (보강토옹벽의 장기거동분석에 관한 연구)

  • Won, Myoung-Soo;Lee, Yong-An;Kim, You-Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.8
    • /
    • pp.33-42
    • /
    • 2006
  • Geosynthetics reinforced soil (GRS) walls with a flexible wall face allow deformation. GRS walls constructed on the weak ground change in both horizontal earth pressures on wall faces and the tensile stress of geosynthetics, affecting the backfill in time until the deformation of the backfill and the foundation is completed. However, there are few studies that were done to measure and analyze the horizontal earth pressures and geosynthetics deformation on GRS walls constructed on the soft ground for a long period of time. Two field GRS walls in this study are constructed on a shallow layer of a weak foundation to measure and analyze geostynthetics deformation, horizontal earth pressures, and pore water pressures for the duration of approximately 16 months. Strain gauges are used to measure geosynthetics deformation; this study specifically suggests a new method of measuring nonwoven geotextile using strain gauges. Most geosynthetics deformation occurred within a month after the construction of GRS walls. The maximum deformation measured for approximately 16 months appeared as follows: nowoven geotextile: 6.05%, woven geotextile: 2.92%, and geogrid: 2.33%. Pore water pressures on the GRS wall can be ignored; however, horizontal earth pressures on the bottom and the upper part of the wall face appear larger than earth pressures at rest.