• Title/Summary/Keyword: Soil flushing

Search Result 99, Processing Time 0.023 seconds

Treatment of Naphtalenes-Contaminated Soil by Surfactant/ Coagulant (계면활성제/응집제를 이용한 나프탈렌 오염토양 처리)

  • Park, Joon-Seok;Park, Jong-Un;Shin, Chul-Ho;Park, Hee-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.2
    • /
    • pp.82-90
    • /
    • 2004
  • This study was conducted to evaluate in situ soil flushing and coagulation for naphtalenes-contaminated soil remediation. Mixed-surfactant of 1% POE12 and 1% SDS (1 : 1 by volume basis) was used as a flushing solution. When 5 pore volumes of mixed -surfactant were added to soil column, the flushing efficiencies of 2-methylnaphtalene and 1,5-dimethylnaphtalene with about 1,500 mg/kg(dry soil) were approximately 80% and 60% respectively. In adding 13 pore volumes of mixed-surfactant, the flushing efficiencies of 2-methylnaphtalene and 1,5-dimethylnaphtalene were 90% and 82%. However, considering in situ soil flushing with distilled water, about 42% and 71% were flushed for 2-methylnaphtalene and 1,5-dimethylnaphtalene by surfactant-only. For about 10,000 mg/kg(dry soil) diesel-contaminated soil, 40% and 70% of TPH were flushed-out in 5 pore volumes and 13 pore volumes addition. However, for naphtalenes in diesel TPH, 90% of flushing efficiency was discovered in adding only 5 pore volumes of flushing solution. There was not discovered significant difference among coagulation efficiencies of 6 kinds of polymers, and the coagulation efficiencies were near 50%.

  • PDF

An Experimental Study on Surfactant Enhanced LNAPL Removal Behavior in Saturated Zone (계면활성제를 이용한 포화지층내 저비중 비수용성 유기용매의 제거거동에 관한 연구)

  • 이재원;박규홍;박준범;임경희
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.291-300
    • /
    • 1999
  • Surfactant flushing for enhancing the removal of BTEX from contaminated sand/clay mixtures was investigated. Eight soil columns packed with relatively undisturbed BTEX contaminated soils, were leached with water, methyl alcohol and then flushed with surfactant with or without several additives. Initial concentrations of BTEX mixture range from 278mg/kg to 1975mg/kg. Initial BTEX removal efficiency was 98% when the contaminated soil was flushed with water of 850 pore volumes. Because of tailing effect, water flushing could not remove below 8mg/kg concentrations during the experimental period. Eventually, the most effective surfactant for flushing was turned out to be 4% SOFTANOL(equation omitted)-90 with 3% ethyl alcohol and 3% SXS. In interrupted flow conditions, the removal efficiency was 99.5% with the flushed water of 95 pore volumes. The BTEX mixture removed from the soil columns during the surfactant flushing ranges from 84.5% to 99.5% of the initial amount for both water leaching(850 pore volumes) and surfactant flushing(95-165 pore volumes), respectively. Test results indicated that surfactant flushing could enhance the removal of BTEX mixture from contaminated soils and could reduce the aqueous phase BTEX mixture concentration in leachate.

  • PDF

Electrokinetic Characteristic of Natural Soil with Flushing Agents (세척제에 따른 자연토의 동전기 특성)

  • 김익현;이정철;김병일;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.635-640
    • /
    • 2003
  • Electrokinetic characteristic of natural soil dependent on flushing agents is studied to determine the best agent used in the hybrid electrokinetic remediation system. The soil containing 7.6% Fe$_2$O$_3$is spiked with lead. The flushing agents to be inject into anode are HCl, Acetic acid, Citric acid, EDTA and SDS. Test results showed that the early electrical potential of EDTA is lower than the value of the others. And the pH in anode reservoir is higher. Elcetrokinetic characteristic of all the sample except for EDTA is about the same.

  • PDF

Improving Soil Washing/flushing Process using a Mixture of Organic/inorganic Extractant for Remediation of Cadmium (Cd) and Copper (Cu) Contaminated Soil (유/무기산 혼합용출제를 이용한 중금속(카드뮴,구리)오염토양 처리공법(soil washing/flushing) 개선에 대한 연구)

  • Lee, Hong-Kyun;Kim, Dong-Hyun;Jo, Young-Hoon;Do, Si-Hyun;Lee, Jong-Yeol;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.17-25
    • /
    • 2009
  • The applicability of soil washing/flushing to treat a contaminated soil with cadmium (Cd) and copper (Cu) using a mixture of organic/inorganic extractant was evaluated in laboratory-scale batch and column tests. Citric acid was the effective extractant to remove Cd and Cu from the soil among various organic acids except EDTA. Carbonic acid was chosen as inorganic extractant which was not only low toxicity to environment, but also increasing soil permeability. Moreover, the optimum ratio of organic and inorganic extractant to remove Cd and Cu was 10 : 1, and this ratio of organic and inorganic extractant achieved removal efficiencies of Cd (46%) and Cu (39%), respectively. The increasing flow rate of extractant could explain the phenomena of soil packing when carbonic acid was used with organic extractant (i.e. EDTA and citric acid). Therefore, a mixture of organic extractant with inorganic extractant, especially carbonic acid, could resolve a problem of soil packing when this extractant was applied to a field application to remove Cd and Cu using in-situ soil flushing process.

Effects of In-Situ flushing on the Bioremediation of Soil Contaminated with Endosulfan (In-Situ Flushing기법이 Endosulfan으로 오염된 토양의 생물학적 처리에 미치는 영향)

  • 전민하;최상일
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.39-47
    • /
    • 2001
  • According to a series of batch-scale washing tests, SDS+$POE_5$ and $POE_5$+$POE_14$ were determined for the applicable mixed surfactants. Because SDS+$POE_5$ showed slightly negative effects on the microbes in the toxicity tests, $POE_5$+$POE_14$((1:1) 1%) was chosen for this study. In the in-situ flushing experiments, the removal rate of endosulfan was 67% for the injection rate of 1.5L/min/$\textrm{km}^2$. And when methanol and ethanol were added as cosolvent, 75% and 81% removal efficiencies were achieved, respectively. In the tests of bioremediation after the application of in-situ flushing, the removal rates of contaminated soils having 13mg/kg dry soil and 3mg/kg dry soil as initial concentrations were 86% and 81%, respectively. There were no significant degradation after 24 hours. The major rate-limiting factor for the biodegradation of endosulfan might be the mass transfer from soil phase to liquid phase after 24 hours. With the addition of surfactant, 89% removal was achieved after 120 hours. Because the surfactant improved the mass transfer rate, the biodegradation of endosulfan was enhanced. When surfactant and cosolvent were added together, the adaptation period of microorganisms to the surfactant became longer and the removal rates were 84% and 83% for methanol and ethanol, respectively.

  • PDF

다종 중금속으로 오염된 사질토에 대한 EK Flushing 기술 적용

  • 김병일;한상재;이군택;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.310-313
    • /
    • 2003
  • The precipitation of heavy metals within the region of pH jump is inevitable in the conventional electrokinetic remediation technology. This study prevents the interest species from precipitating through the injection of flushing solutions in which HCl, acetic acid, citric acid, EDTA and SDS dissolved. The cumulative flow resulted from electroosmosis appear in order of Citric acid

  • PDF

Performance of Soil Flushing for Contaminated Soil Using Surfactant (계면활성제를 이용한 오염 토양 세정 성능 평가)

  • Lee, Chaeyoung;Jang, Yeongsu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.6
    • /
    • pp.17-23
    • /
    • 2011
  • In this study, a series of experiments were carried out to remove total petroleum hydrocarbon(TPH) and toluene by soil flushing. In batch experiments, Triton X-100 and SWA 1503 showed TPH removal efficiency of 79.0% and 69.0%, respectively. Although the TPH removal efficiency increased as the surfactant was increased in the concentration range 1-11mmol/L, the optimum concentration was 1mmol/L, considering the ratio of the removal efficiency to the amount of surfactant injected. In column experiment, the optimal velocity was 0.3mL/min. The physical aquifer model(PAM) result revealed that the soil flushing removed as much as 5.5% of the toluene under 3 pore volume(PV) conditions. To improve the soil flushing efficiency, it is necessary to find optimal condition through recirculation or reuse of surfactant.

Derivation of Optimum Operating Conditions for Electrical Resistance Heating to Enhance the Flushing Effect of Heavy Oil Contaminated Soil (중질유 오염토양의 세정효과를 증진시키기 위한 전기저항가열의 최적 운전조건 도출)

  • Lee, Hwan;Jung, Jaeyun;Kang, Doore;Lee, Cheolhyo
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.3
    • /
    • pp.219-229
    • /
    • 2020
  • This study evaluated the applicability of the convergence technology by deriving the optimum conditions about operating factors of electrical resistance heating to enhance the soil flushing effect on soil contaminated with bunker C oil in the coastal landfill area. As a result of the batch scale experiment, the flushing efficiency of the VG-2020 was higherthan that of the Tween-80, and the flushing efficiency increased by about 1.4 times at 60℃ compared to room temperature. As a result of the electrical resistance heating box experiment, soil temperature rose to 100℃ in about 40~80 minutes in soil with water content of 20~40%, and it was found that the heat transfer efficiency is excellent when the pipe-shaped electrode rod with STS 316 material is located in a triangular arrangement in saturated soil. In addition, it was confirmed that the interval between the electrode rods to maintain the soil temperature above 60℃ under the optimum conditions was 1.5 m, and the soil flushing box experiment accompanying electrical resistance heating showed TPH reduction efficiency of about 55% at 5 Pore Volume, and satisfied the Korean standard for the conservation of soil (less than TPH 2,000 mg/kg) at 10 Pore Volume.

Application of Artificial Neural Networks(ANN) to Ultrasonically Enhanced Soil Flushing of Contaminated Soils (초음파-토양수세법을 이용한 오염지반 복원률증대에 인공신경망의 적용)

  • 황명기;김지형;김영욱
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.343-350
    • /
    • 2003
  • The range of applications of artificial neural networks(Am) in many branches of geotechnical engineering is growing rapidly. This study was undertaken to develop an analysis model representing ultrasonically enhanced soil flushing by the use of ANN. Input data for the model-development were obtained by laboratory study, and used for training and verification. Analyses involved various ranges of momentum, loaming rate, activation function, hidden layer, and nodes. Results of the analyses were used to obtain the optimum conditions for establishing and verifying the model. The coefficient of correlation between the measured and the predicted data using the developed model was relatively high. It shows potential application of ANN to ultrasonically enhanced soil flushing which is not easy to build up a mathematical model.

Surfactant Enhanced In-Situ Soil Flushing Pilot Test for the Soil and Groundwater Remediation in an Oil Contaminated Site (계면활성제 원위치 토양 세정법을 이용한 유류 오염 지역 토양.지하수 정화 실증 시험)

  • 이민희;정상용;최상일;강동환;김민철
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.77-86
    • /
    • 2002
  • Surfactant enhanced in-situ soil flushing was performed to remediate the soil and groundwater at an oil contaminated site, where had been used as a military vehicle repair area for 40 years. A section from the contaminated site (4.5 m $\times$ 4.5 m $\times$ 6.0 m) was selected for the research, which was composed of heterogeneous sandy and silt-sandy soils with average $K_d$ of 2.0$\times$$10^{-4}$cm/sec. Two percent of sorbitan monooleate (POE 20) and 0.07% of iso-prophyl alcohol were mixed for the surfactant solution and 3 pore volumes of surfactant solution were injected to remove oil from the contaminated section. Four injection wells and two extraction wells were built in the section to flush surfactant solution. Water samples taken from extraction wells and the storage tank were analyzed on a gas-chromatography (GC) for TPH concentration in the effluent with different time. Five pore volumes of solution were extracted while TPH concentration in soil and groundwater at the section were below the Waste Water Discharge Limit (WWDL). The effluent TPH concentration from wells with only water flushing was below 10 ppm. However, the effluent concentration using surfactant solution flushing increased to 1751 ppm, which was more than 170 times compared with the concentration with only water flushing. Total 18.5 kg of oil (TPH) was removed from the soil and groundwater at the section. The concentration of heavy metals in the effluent solution also increased with the increase of TPH concentration, suggesting that the surfactant enhanced in-situ flushing be available to remove not only oil but heavy metals from contaminated sites. The removal efficiency of surfactant enhanced in-situ flushing was investigated at the real contaminated site in Korea. Results suggest that in-situ soil flushing could be a successful process to remediate contaminated sites distributed in Korea.