• Title/Summary/Keyword: Soil corrosion

Search Result 132, Processing Time 0.027 seconds

Relationships of Chemical Elements and their Environmental Impacts in Groundwater, Soil, and Fodder Plants in Arid Land

  • Hamdan, Ali;Khozyem, Hassan;Elbadry, Eman
    • Economic and Environmental Geology
    • /
    • v.54 no.3
    • /
    • pp.331-352
    • /
    • 2021
  • The relationship of both heavy metals and major elements in soil, plants, and groundwater was studied in a hyper-arid area and depends completely on the groundwater to cover its all needs. The study reviles that 27.3% of the studied groundwater was strongly acidic and has very low pH values (

A Study of Optimizing Cathodic Protection in Comparison of Design Methodologies

  • Choi, Young-Kwan;Choi, Sang-Yule;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.11
    • /
    • pp.23-29
    • /
    • 2010
  • The principal factor determining an optimum design method for cathodic protection is finding the protection current for preventing the corrosion of existing, already laid pipe. Some factors currently used to test designs include the sizes and lengths of pipes, soil resistivity, and the coating damage rate. We believe this method and current formulae are not optimum due to the uncertainty of determining the coating damage rate and the corrosion protection current's density. This paper analyzes the amount of protection current obtained by performing a temporary current test using data describing existing laid pipe. We then propose determining the corrosion protection current by using the temporary current test after modifying the formula. In addition, we suggest a way to choose optimized cathodic protection and the process of design by executing the design and taking account of such factors as a site condition of 34km-long non-protected water supply pipe lines (stages I and II) in ${\bigcirc}{\bigcirc}$ region, climate, interferences, and durability.

Properties of Compressive Strength of Mortar Mixed with WCP for Soil Pavement (폐콘크리트분말 혼합 흙도로 포장용 모르타르의 압축강도 특성)

  • Moon Han Young;Choi Yun Wang;Song Yong Kyu;Moon Dae Joong;Shin Hwa Cheol;Jung Chul Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.537-540
    • /
    • 2004
  • Recently, for industrial development period, concrete structures in domestics have been increased. They were deteriorated by attack of carbonation, freeze-thaw and corrosion etc. In hence they were demolished and reconstructed, resulted in waste concrete particles. In this paper, waste concrete particles (WCP) by product from different crushing and selecting process were used in soil cement-based pavement in the various recycling. For using WCP in soil cement-based pavement, the Qualities, physical and chemical properties, of WCP should be researched. In the first step, the specified compressive strength of mortar for two types of clay sand soil and clay soil respectively was experimented to be 15 Mpa and then optimum mixing ratio of chemical solidification agent were decided in the range of $1.5\~3.0\%$ in the replacement with cement weight content. In the second step, based on the prior experimental results, recycling possibility of WCP in soil cement-based pavement was studied. In the result of experiment the mixing ratio of WCP were 5, 10, 15 and $20\%$ in the replacement with soil weight and the compressive strength of mortar was somewhat decreased according to the increase of the mixing ratio of WCP.

  • PDF

Study of Corrosion Characteristics of Corroded Iron Objects from Underwater by Sulfides (해저 철제유물의 황화물에 의한 부식특성 연구)

  • Kim, Taek Joon;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.29 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • This study is on the corrosion of iron objects caused by sulfides in undersea environment. The corrosion state of objects in seawater and their damage state after underwater and left in highly humid air were studied. The samples of this study were four iron objects which had been taken out from undersea mud layer located in Taean Mado, Chungcheongnamdo. SEM-EDS and XRD analyse on the objects to check whether they have sulfides or not. The result of analysis suggested that the major component of corrosion product generated in undersea deposit soil is sulfur(S) and iron sulfide(FeS) is formed as sulfide. However, there was no clear corrosion on the surface of objects which was exposed to sea water because of the impact of concretion which covered the surface. In order to check the damage status of iron objects after they had been taken out of sea water, exposure tests in high humidity environment and dehumidified environment were done on the corrosion products. The result of the test suggested that the oxidization of iron sulfide corrosion product makes iron sulfate ($FeSO_4$) and sulfuric acid ($H_2SO_4$) and they can cause secondary corrosion of iron objects. Therefore, it is believed that the iron sulfide corrosion product of iron objects taken out from underwater environment should be removed by all means and the keeping environment of the iron objects should also maintain dehumidified state.

Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류 모니터링용 실시간 무선 원격 감시 시스템)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2729-2731
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. In this paper, results of development about Real-time Wireless Remote Monitoring System for Stray Current of Subway System are presented.

  • PDF

The Buried Type Reference Electrode for Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류의 실시간 무선 원격 감시 시스템용 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2732-2734
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development about the permanent buried type reference electrode($Cu/CuSO_4$) are presented.

  • PDF

The Development of Buried Type Reference Electrode Using Porous Ceramic(${\alpha}-Al_{2}O_{3}$) (다공성 세라믹(${\alpha}-Al_{2}O_{3}$)를 이용한 지중 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.145-147
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development of buried type reference electrode using porous ceramic$({\alpha}-Al_{2}O_{3})$ are presented.

  • PDF

Enhancing the Reliability of Coating Flaw Detection for Pipes Buried in Soil Using a Multi-Electrode Detector (다전극 탐상을 통한 토중 매설배관 피복결함 탐상 정확도의 개선)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.265-280
    • /
    • 2020
  • External corrosion of buried pipes can be controlled using both coating and cathodic protection. However, deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detection methods is affected by interference such as metal objects connected to rectifiers and copper grids. When performing parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potential reversal in voltage gradient appears in the area where the interference exists. However, this area may be not identified using existing methods. The objective of this study was to determine the effect of analyzing direction on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe was repeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coating flaw detection was improved by up to 46.4% compared to the conventional method.

Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures (지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발)

  • Ha, Y.C.;Bae, J.H.;Ha, T.H.;Lee, H.G.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

Immobilization Characteristics of Hexavalent Chromium Contaminated Soils Treated with Phosphate and Chromium Reducing Agent (크롬환원제와 인산염으로 처리된 6가 크롬 오염토양의 고정화)

  • Lee, Eui-Sang
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Hexavalent chromium-contaminated soils are encounted at many unregulated discharge and improper handling of wastes from electroplating, leather tanning, steelmaking, corrosion control, and wood preservation industries. Contamination of hexavalent chromium in the soil is a major concern because of its toxicity and threat to human life and environment. Current technologies for hexavalent chromium-contaminated soil remediation are usually costly and/or cannot permanently prohibit the toxic element from entering into the biosphere. Thus, as an alternative technique, immobilization is seen as a cost-effective and promising remediation technology that may reduce the leachable potential of hexavalent chromium. The purpose of this paper is to develope an immobilization technique for the formation of the geochemically stabilized hexavalent chromium-contaminated soil from the reactions of labile soil hexavalent chromium forms with the added soluble phosphate and chromium reducing agent. From the liquid phase experiment, reaction order of chromium reducing agent, soluble phosphate, alkali solution shows the best removal efficiency of 95%. In addition, actual soil phase experiment demonstrates up to 97.9% removal efficiency with 1:1 molar ratio of chromium reducing agent and soluble phosphate. These results provide evidence for the potential use of soluble phosphate and chromium reducing agent for the hexavalent chromium-contaminated soil remediation.