• Title/Summary/Keyword: Soil arch

Search Result 66, Processing Time 0.019 seconds

Seismic response of single-arch large-span fabricated subway station structure

  • He, Huafei;Li, Zhaoping
    • Earthquakes and Structures
    • /
    • v.23 no.1
    • /
    • pp.101-113
    • /
    • 2022
  • A new type of fabricated subway station construction technology can effectively solve these problems. For a new type of metro structure form, it is necessary to clarify its mechanical properties, especially the seismic performance. A soil-structure elastoplastic finite element model is established to perform three-dimensional nonlinear dynamic time-history analysis based on the first fabricated station structure-Yuanjiadian station of Changchun Metro Line 2, China. Firstly, the nonlinear seismic response characteristics of the fabricated and cast-in-place subway stations under different seismic wave excitations are compared and analyzed. Then, a comprehensive analysis of several important parameters that may affect the seismic response of fabricated subway stations is given. The results show that the maximum plastic strain, the interlayer deformation, and the internal force of fabricated station structures are smaller than that of cast-in-place structure, which indicates that the fabricated station structure has good deformation coordination capability and mechanical properties. The seismic responses of fabricated stations were mainly affected by the soil-structure stiffness ratio, the soil inertia effect, and earthquake load conditions rarely mentioned in cast-in-place stations. The critical parameters have little effect on the interlayer deformation but significantly affect the joints' opening distance and contact stress, which can be used as the evaluation index of the seismic performance of fabricated station structures. The presented results can better understand the seismic responses and guide the seismic design of the fabricated station.

Geophysical Techniques for Underwater Landslide Monitoring (수중 산사태 모니터링을 위한 지반물리탐사기술)

  • Truong, Q. Hung;Lee, Chang-Ho;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.5-16
    • /
    • 2007
  • The monitoring and investigation of underwater landslide help to understand its mechanism, increase the usefuless of design and construction and reduce the losses. This paper presents three high resolution geophysical techniques electrical resisitance, ultrasonic wave reflection imaging, and shear wave tomography conducted to determine the lab-scaled submerged landslide. Electrical resistance profiles of a soil mass obtained by an electrical resistance probe provide detailed information to assess the spatial distribution of the soil mass with milimetric resolution. An ultrasonic wave image obtained by recording the reflections from interfaces of different impedance materials permits detecting layers and landslide with submilimetric resolution. The pixel based image of immersed landslides is created by the inversion of the boundary information achieved from the traveling time of shear waves. The experimental results show that the ultrasonic wave imaging and the electrical resistance can provide complementary information; and their association with S-wave tomography image can produce a 3-D view of the underwater landslide. This study suggests that geophysical techniques may be effective tools for the detection of the underwater landslides and spatial distribution offshore.

Seismic Response Analyses for Whole Power Block of Nuclear Facilities Considering Structure-Soil-Structure Interaction and Various Parameters (원자력발전소 파워블럭에 대한 구조물-지반-구조물 상호 작용과 다양한 매개변수를 고려한 지진응답해석)

  • Seo, Choon Gyo;Jang, Dong Hui;Jung, Du Ri;Chang, Soo Hyuk;Moon, Il Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.333-343
    • /
    • 2018
  • In this paper, we study the existing results of the structure-soil-structure interaction (SSSI) effect on seismic responses of structures and summarize important parameters. The parameters considered in this study are a combination of buildings in the power block of a nuclear power plant, the characteristics of earthquake ground motions and its direction, and the characteristics embedded under the ground. Based on these parameters, the seismic analysis model of the structures in the power block of the nuclear power plant is developed and the structure-soil-structure interaction analyses are performed to analyze the influence of the parameters on the seismic response. For all analyses, the soil-structure interaction (SSI) analysis program CNU-KIESSI, which was developed to enable large-sized seismic analysis, is used. In addition, the SSI analyses is performed on individual structures and the results are compared with the SSSI analysis results. Finally, the influence of the parameters on the seismic response of the structure due to the SSSI effect is reviewed through comparison of the analysis results.

Estimation Method of Earth Pressures Acting on a Row of Piles due to Lateral Soil Movements (측방변형지반속 줄말뚝에 작용하는 토압의 산정법)

  • 홍원표;송영석
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.13-22
    • /
    • 2004
  • In case of the lateral movement accurring at soft ground where a row of piles are installed, the crown failure at external arch zone of soil arching is firstly developed, and the cap failure at wedge zone in front of piles is lastly developed. Therefore, the lateral earth pressure acting on a row of piles due to soil movement should be calculated in each condition of crown and cap failures around piles. A theoretical equation of crown failure can be proposed using a cylindrical cavity expansion theory. The theoretical equation of crown failure is mainly affected by two factors. One is related to soil properties such as internal friction angle, cohesion and horizontal pressure, and the other is related to pile factors such as diameter, installation interval. Meanwhile, the yield range of lateral earth pressure is established in the estimation of theoretical equation based on crown and cap failures around piles. The theoretical values based on crown and cap failures are compared with the experimental values. The experimental values are located in the range proposed by theoretical values. Thus, it is confirmed that the theoretical values proposed in the study are very reasonable.

Tension Crack and Lateral Pressure on Gravity Wall Backfilled by Cohesive Soil : Undrained Analysis (점성토로 뒤채움된 중력식옹벽에서의 인장균열 및 수평토압 : 비배수 해석)

  • 정성교;김형수
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.135-148
    • /
    • 1997
  • Coulomb's theory has been usually used in practice to obtain lateral earth pressure against retaining wall. Such theory is based in the assumption that the lateral pressure is a tai angular distribution, since the point of applying the lateral thrust cannot be obtained by using it. However, the results of laboratory and field tests showed that the lateral pressure was not a triangular but a nonlinear distribution. To overcome the drawback of the Coulomb's theory, the different theoretical approaches(Handy, 1985. Kingsley, 1989 : Kellogg, 1993, Chung et at,1993, 1996a) were performed for gravity wall backfilled by cohesionless soil. On the other hand, for retaining wall backfilled by ,cohesive soil, theoretical analyses were carried out only on the basis of the Rankine's or Coulomb's concepts, but the equations showed different results. Here was newly derived the equations of lateral pressures under undrained condition against gravity wall backfilled by cohesive soil. They were based on the Coulomb's wedge, adopted the arching concept. Some of the equations were derived by neglecting tension crack, while the others by considering it. Comparative results for applying different examples showed that the equation considering tension crack might be reasonable.

  • PDF

Current Status of Ginseng Cultivation and Soil Characteristics of Northeastern Three Provinces in China

  • Park, Yang Ho;Kim, Jang Uk;Kim, Dong Hwi;Sonn, Yeon Kyu;Yun, Jin Ha;Moon, Huhn Pal;Cho, Soo Yeon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.6
    • /
    • pp.795-806
    • /
    • 2016
  • This study was conducted to improve the continuous techniques for international competitiveness of ginseng industry to Korea-China FTA negotiation and conclusion, and provide the basic information for ginseng industry development of Korea. It was carried out the visiting of the northeastern three provinces (Jilin, Liaoling and Heilongjang) in China for 3-year from 2014 to 2016 and observed the farmers' fields of ginseng cultivation with soil environmental status. The types of ginseng cultivation could be observed in small scales of 0.5~3.0 ha, in middle scales of 4.0~10.0 ha and in large scales of 30~700 ha with the kinds of imhasam, Chinese ginseng, Korean ginseng and western ginseng. Also ginseng was cultivated in newly reclaimed land of forest in two types of direct seeding and transplanting of ginseng seedlings. The field beds of ginseng growing were covered with vinyl films in arch design of 100~130 cm height and vinyl was painted in spraying with blue, green and yellow colours for shading. It was investigated in status of the physico-chemical properties of soils. The physical information on the field soils were silt loam, loam and sandy loam in soil textures, and some plain in low slope, some alluvial fan or local valley in forest of land topography. Soil pH ranged within 5.0~5.2, soil EC was $0.93{\sim}3.78dS\;m^{-1}$, organic matter was $37{\sim}35g\;kg^{-1}$, nitrate nitrogen $63{\sim}490mg\;kg^{-1}$, available $P_2O_5$ $55{\sim}163mg\;kg^{-1}$, and in exchangeable cations, K was 0.30~0.98, Ca was 6.5~14.0, Mg was $1.1{\sim}5.3cmol_c\;kg^{-1}$ in ranges. Farmers used the fertilizer for ginseng cultivation in 10~11 t of compost, $200{\sim}400kg\;ha^{-1}$ of complex fertilizer and $750kg\;ha^{-1}$ of oil cakes. The northeastern three provinces of China can use the newly lands with large areas of ginseng cultivation in soil sickness by continuous cropping. and the soil basic fertility is batter than that of Korean in standard guide of ginseng cultivation soil.

Soil arching analysis in embankments on soft clays reinforced by stone columns

  • Fattah, Mohammed Y.;Zabar, Bushra S.;Hassan, Hanan A.
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.507-534
    • /
    • 2015
  • The present work investigates the behavior of the embankment models resting on soft soil reinforced with ordinary and stone columns encased with geogrid. Model tests were performed with different spacing distances between stone columns and two lengths to diameter ratios (L/d) of the stone columns, in addition to different embankment heights. A total number of 42 model tests were carried out on a soil with undrianed shear strength $${\sim_\sim}10kPa$$. The models consist of stone columns embankment at s/d equal to 2.5, 3 and 4 with L/d ratio equal 5 and 8. Three embankment heights; 200 mm, 250 mm and 300 mm were tested for both tests of ordinary (OSC) and geogrid encased stone columns (ESC). Three earth pressure cells were used to measure directly the vertical effective stress on column at the top of the middle stone column under the center line of embankment and on the edge stone column for all models while the third cell was placed at the base of embankment between two columns to measure the vertical effective stress in soft soil directly. The performance of stone columns embankments relies upon the ability of the granular embankment material to arch over the 'gaps' between the stone columns spacing. The results showed that the ratio of the embankment height to the clear spacing between columns (h/s-d) is a key parameter. It is found that (h/s-d)<1.2 and 1.4 for OSC and ESC, respectively; (h is the embankment height, s is the spacing between columns and d is the diameter of stone columns), no effect of arching is pronounced, the settlement at the surface of the embankment is very large, and the stress acting on the subsoil is virtually unmodified from the nominal overburden stress. When $(h/s-d){\geq}2.2$ for OSC and ESC respectively, full arching will occur and minimum stress on subsoil between stone columns will act, so the range of critical embankment height will be 1.2 (h/sd) to 2.2 (h/s-d) for both OSC and ESC models.

Model Tests for Vertical Loads Acting on Embankment Piles (성토지지말뚝에 작용하는 연직하중에 대한 모형실험)

  • 홍원표;강승인
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.171-181
    • /
    • 2000
  • A series of model tests were performed both to investigate the load transfer by soil acrching in fills above embankment pils and to verify of the theoretical analysis. In the model tests, the piles were installed in a row below the embankment and the cap beams were placed on the pile heads perpendicular to the longitudinal axias of the embankment. The space between pile cap beams and the embankment height was focused as the major factors affecting the load transfer in embankment fill. When the embankment fill was higher than the minimum required height, which was about 33% higher than the radius of the soil arch proposed by theoretical discussion in the previous study, not only the soil arching could be developed completely but also the experimental results showed good agreement with theoretical predictions. The portion of the embankment load carried by model pile cap beams decreased with increment of the space between pile cap beams, while it increased with increment of the embankment height. Therefore, to maximize the effect of embankment load transfer by piles on design, the interval ratio of pile cap beams should be decreased under considerably high embankments by reducing the space between cap beams and/or enlarging the width of pile cap beams.

  • PDF

A Case Study on the Design of Drilled Shaft on Soft Ground in Vietnam (베트남 연약지반에서의 현장타설말뚝 설계 사례)

  • Seo, Won-Seok;Cho, Sung-Han;Choi, Ki-Byung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.591-604
    • /
    • 2008
  • In this study, two design examples of drilled shafts on soft ground in Ho-Chi-Minh City, Vietnam are introduced. One is for a 27-story apartment and the other is for a Arch bridge over Saigon river. Unlikely the normal cases in Korea, all of the bored pile foundations are supposed to be placed on soil layers. Therefore, skin friction between pile and ground is the most crucial design parameter. Three methods using SPT N value of sandy soil -Korean Road Bridge Code(1996), Reese and Wright (1977), and O'Neill and Reese (1988)- were adopted to obtain an ultimate axial bearing capacity. In order to verify the calculated bearing capacity, 3 sets of static load test and a Osterberg Cell test were performed at an apartment site and a bridge site respectively. LRFD (Load Resistance Factored Design) method was compared with ASD (Allowable Stress Design) method. On application of ASD method, safety factor for skin friction was adopted as 2 or 3 while safety factor for end bearing was 3. The design bearing capacities from ASD method matched well with those from LRFD method when safety factor for skin friction was adopted as 2.

  • PDF

First Report of Meloidogyne marylandi (Tylenchida : Heteroderidae) in Korea (한국미기록종인 잔디뿌리혹선충, Meloidogyne marylandi (참선충목 : 씨스트선충과)에 대한 보고)

  • 강상진;박병용;최동로;한상찬
    • The Korean Journal of Soil Zoology
    • /
    • v.7 no.1_2
    • /
    • pp.45-49
    • /
    • 2002
  • Meloidogyne marylandi Jepson & Golden, 1987 is described from Zoysia grass collected in Cheonan, Korea. The nematode did not produce galls, and females were generally surrounded by a massive egg sac. Perineal patterns of female were a high to rounded arch with shoulders, wavy striae usually forming a rough. Vulva and anus were sunken. Second-stage juvenile body length was 390.3 $\mu\textrm{m}$ (290-430), tail length 55.1 $\mu\textrm{m}$ (49-59) and lateral field with 4 incisures. Male stylet length was 18.1 $\mu\textrm{m}$ (15-24), spicules length 26.2 $\mu\textrm{m}$ (23-29) and lateral field with 4-5 incisures.

  • PDF