• Title/Summary/Keyword: Soil and Groundwater

Search Result 3,603, Processing Time 0.029 seconds

Artifical Groundwater Recharge Using Underground Piping Method

  • Ahn, Sang-Jin;Lee, Jong-Hyong
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.11-29
    • /
    • 1992
  • Recently, rapid industrialization, urbanization and higher living standards accelerate to increase groundwater consumption resulting in continuously dropping groundwater elevations. To maintain enough groundwater volume without dropping groundwater elevations, the proper groundwater rechatge is necessary. The groundwater rechatge can be classified into two categories which are natural rechatge and artiticial rechatge. Even though the natural rechatge through by dired infiltration from the rainfall is desirable, the artificial groundwater rechatge is necessaty when the increment of groundwater consumption exceeds natural recharge rate. Well method and scattering method are utilized as artificial rechatging method, a severe disadvantage, which is the reduction of the void of soil surface, is indicated in the well method. Recently, the underground piping method, which is a scattering method, is receiving increasing attention as a proper recharging method. The method is indirectly to supply water to the underground using an underground piping system. Therefore, the void of soil surface is not severely reduced and better infiltration rate can be achieved. In this paper, the artificial groundwater rechatge using underground piping method is investigated through experiments and numerical analysis. The influence of the groundwater by underground piping method is evaluated through comparing recharging heights. Good agreements between experiments and numerical analysis are obtained and the artificial groundwater recharge by underground piping method is well tested and verified.

  • PDF

Efficient Management Method of Groundwater in Farming and Fishing Villages (농어촌 지하수의 효율적 관리 방안)

  • Jung, Chan-Duck;Kim, Yang-Bin;Park, Ki-Yeon;Park, Sun-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.81-90
    • /
    • 2012
  • Groundwater is our invaluable asset because it takes action in the case of climates changes like drought or floods. But the Korean government has formulated water-resource policies mostly focused on surface water. As a result, the groundwater that will be more important resource in the future has been treated carelessly, caused neglect of maintenance and resulted many abandoned wells. This poor management of groundwater is because of lack of organization on our asset, manpower, unclearness of managing body, shoddy construction and lack of supervision. In order to solve this problem, we need a special agency of groundwater that contribute people's awareness by promotion importance of groundwater, dissemination of technical education and professionals. To do that, we have to establish a specific groundwater management plan based on regional characteristics of watersheds and specialized institution need to promote responsible development and usage in groundwater.

Some Consideration of Groundwater Quality Characteristics in Nakdong River Region - Analysis of Correlation between Electrical Conductivity(EC) and Total Dissolved Solid(TDS) - (낙동강권역 지하수 수질 특성 고찰 - 전기전도도와 총고용물 함량의 상관성 분석을 중심으로 -)

  • 김형수;원이정;박희열
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.40-43
    • /
    • 2000
  • Groundwater qualities in Nakdong river region were investigated during 1999 and 2000. Groundwater samples were collected twice from about 150 sites over the region. The EC and TDS obtained in first survey (October, 1999) show rather high values than those in second survey(April, 2000) and this seems to be caused by groundwater temperature. There is obvious positive correlation between EC and TDS. For the study area, the following equation can be written : TDS(mg/l) = <0.64~0.70> x EC($mutextrm{s}$/cm). As the concentration of major ions increases in natural condition, there is a tendency that the ratio of TDS and EC has consistent value. This observation suggests that TDS measurement can be replaced by EC measurement in the some ranges.

  • PDF

A Study on the Effects of Heat Pump Using Standing Column Well on Soil and Groundwater Microorganisms (스탠딩컬럼웰을 적용한 지열히트펌프의 토양 및 지하수 미생물에 대한 영향 연구)

  • Jun, Jungeui;Park, Sisam;Na, Sangmin;Rhee, Keonjoong;Park, Jaewoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.93-101
    • /
    • 2009
  • Standing column well (SCW) heat pump system produces geothermal energy by the heat exchange of the groundwater. If SCW system changed the temperature of soil and groundwater, it could also change species or population of microorganisms. Therefore it is needed to research about the effect of temperature change on microorganisms to use eco-friendly geothermal energy. We produced the simulative heat pump system (SHPS) and observed the change of the soil temperature in SHPS. Characteristic analysis of microorganisms isolated from soil was performed and groundwater temperature variation was evaluated. Also the bleeding effect in SHPS was investigated and the results are included. As the results, the population of microorganisms was increased about 90%, as the groundwater temperature increased 2-3 celsius degree. However the species of microorganism was little influenced by the temperature change of the soil.

  • PDF

제주도 남사면지역의 지하지질구조와 지하수산출특성

  • 김창옥;윤정수;정차연
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.255-258
    • /
    • 2003
  • The purpose of this study is to understand characteristics of stream and spring water and subsurface geologic structure in Seogwipo area. This study area is surrounded by various smaller parasitic volcanic cinder cones, tuff cones, strangely shaped basalt and trachyte rocks, beautiful waterfalls. The geologic structure in study area is classified into the Upper layer(volcanic rocks), Middle layer(SGF), Lower layer(UF), and Basement layer. The groundwater in Seogwipo area is classified into the Upper layer groundwater, Middle layer groundwater, Lower layer groundwater and Basement layer groundwater on the basis of the hydrostratigraphy structure.

  • PDF

Review of Analytical and Assessment Techniques of Terminal Electron Accepting Processes (TEAPs) for Site Characterization and Natural Attenuation in Contaminated Subsurface Environments (오염 지중환경 특성화와 자연저감평가를 위한 말단전자수용과정(TEAPs) 분석 및 평가기술 소개)

  • Song, Yun Sun;Kim, Han-Suk;Kwon, Man Jae
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.2_spc
    • /
    • pp.1-15
    • /
    • 2020
  • Monitoring and assessing terminal electron accepting processes (TEAPs) are one of the most important steps to remediate contaminated sites via various in-situ techniques. TEAPs are a part of the microbial respiration reactions. Microorganisms gain energy from these reactions and reduces pollutants. Monitoring TEAPs enables us to predict degradability of contaminants and degradation rates. In many countries, TEAPs have been used for characterization of field sites and management of groundwater wells. For instance, US Environmental Protection Agency (EPA) provided strategies for groundwater quality and well management by applying TEAPs monitoring. Denmark has also constructed TEAPs map of local unit area to develop effective groundwater managing system, particularly to predict and assess nitrogen contamination. In case of Korea, although detailed soil survey and groundwater contamination assessment have been employed, site investigation guidelines using TEAPs have not been established yet. To better define TEAPs in subsurface environments, multiple indicators including ion concentrations, isotope compositions and contaminant degradation byproducts must be assessed. Furthermore, dissolved hydrogen concentrations are regarded as significant evidence of TEAPs occurring in subsurface environment. This review study introduces optimal sampling techniques of groundwater and dissolved hydrogen, and further discuss how to assess TEAPs in contaminated subsurface environments according to several contamination scenarios.

Development of Monitoring Site Selection Criteria of the Korean Soil Quality Monitoring Network to Meet its Purposes (토양측정망 운영목적에 따른 토양측정망 지점 선정 방안 연구)

  • Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.2
    • /
    • pp.19-26
    • /
    • 2013
  • This study developed the classification of National Soil Quality Monitoring Network (NSQM) and its site selection criteria to meet the recently established purposes of the NSQM. The NSQM were suggested by this study to classify into the six-purposes site groups from the current classification of land uses. The six purposes site groups were 1) intensive observation sites, 2) contaminant loading sites, 3) human activity sites, 4) background sites, 5) river soil sites, and 6) sites near the groundwater quality monitoring wells. Furthermore, this study developed the site selection criteria of NSQM utilizing the accumulated NSQM data, road traffic data, chemical emission data, census, soil information, and the literature related to soil quality variation due to contaminant loads. For selecting suitable sites for NSQM, this study used road traffic, chemical emission, the distance from the contaminant sources, and population information as specific criteria. The suggested site classification and criteria were appled for the current 100 NSQM sites for evaluation. Forty sites were met to the criteria suggested by this study, but sixty sites were not met to the criteria. However, some of the sixty sites also included the obscure sites that their addresses were not apparent to find them.

토질조건에 따른 납 오염토양의 Electrokinetic 정화 효율

  • 김병일;조용실;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.34-37
    • /
    • 2002
  • In this study, electrochemical characteristics variation and removal efficiency with initial pH and mineral compositions during electrokinetic remediation of lead contaminated soils were investigated. Test results showed that heavy metal transportation affected by soil characteristics and electrochemical characteristics varied during electrokinetic remediation. Therefore, in the application of enhanced electrokinetic remediation technique to increase removal efficiency, discrete selection of enhanced technique with characteristics of targeted soil were needed.

  • PDF

불포화 사질토 지반의 지반조건 및 침출수 오염도에 따른 전기비저항의 변화

  • 오명학;이주형;박준범;김형석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.47-50
    • /
    • 2001
  • The laboratory tests were peformed to investigate the relationship between electrical resistivity and the unsaturated subsurface condition and to evaluate the contamination due to leachate based on measuring electrical resistivity. For weathered granite soil, the electrical resistivity of soil decreases as moisture density increases. The electrical resistivity of soil decreases as the concentration of leachate in pore fluid increases since leachate contains various ionic constituents. And the modified Archie's equation for applying to unsaturated sand is derived by regression analysis.

  • PDF