• 제목/요약/키워드: Software Comparison

Search Result 1,423, Processing Time 0.043 seconds

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

A Performance Evaluation of the e-Gov Standard Framework on PaaS Cloud Computing Environment: A Geo-based Image Processing Case (PaaS 클라우드 컴퓨팅 환경에서 전자정부 표준프레임워크 성능평가: 공간영상 정보처리 사례)

  • KIM, Kwang-Seob;LEE, Ki-Won
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.4
    • /
    • pp.1-13
    • /
    • 2018
  • Both Platform as a Service (PaaS) as one of the cloud computing service models and the e-government (e-Gov) standard framework from the Ministry of the Interior and Safety (MOIS) provide developers with practical computing environments to build their applications in every web-based services. Web application developers in the geo-spatial information field can utilize and deploy many middleware software or common functions provided by either the cloud-based service or the e-Gov standard framework. However, there are few studies for their applicability and performance in the field of actual geo-spatial information application yet. Therefore, the motivation of this study was to investigate the relevance of these technologies or platform. The applicability of these computing environments and the performance evaluation were performed after a test application deployment of the spatial image processing case service using Web Processing Service (WPS) 2.0 on the e-Gov standard framework. This system was a test service supported by a cloud environment of Cloud Foundry, one of open source PaaS cloud platforms. Using these components, the performance of the test system in two cases of 300 and 500 threads was assessed through a comparison test with two kinds of service: a service case for only the PaaS and that on the e-Gov on the PaaS. The performance measurements were based on the recording of response time with respect to users' requests during 3,600 seconds. According to the experimental results, all the test cases of the e-Gov on PaaS considered showed a greater performance. It is expected that the e-Gov standard framework on the PaaS cloud would be important factors to build the web-based spatial information service, especially in public sectors.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.

The Influence of Self-Leadership of Research and Development Practitioners on Innovative Behavior via Job Satisfaction : A Comparison between Manufacturing and ICT Industries (국내 기업 연구개발 종사자의 셀프리더십이 직무만족을 매개로 혁신행동에 미치는 영향 : 제조업과 정보통신업 비교)

  • Choi, Min-seog;Hwang, Chan-gyu
    • Journal of Venture Innovation
    • /
    • v.7 no.1
    • /
    • pp.91-110
    • /
    • 2024
  • In this study, we compared and analyzed the influence of self-leadership on innovative behavior and the mediating effect of job satisfaction among R&D practitioners in manufacturing and information communication technology (ICT) industries. To accomplish this, we conducted an online survey using random sampling methods and collected data from 209 respondents. We employed exploratory factor analysis, reliability analysis, correlation analysis, multiple regression analysis, and mediation analysis using SPSS 20.0 software to analyze the data and to compare differences between the manufacturing and ICT sectors. The research findings are as follows: Firstly, both in manufacturing and ICT sectors, self-leadership showed significant positive correlations with job satisfaction and innovative behavior. Secondly, in the analysis of the impact of self-leadership on innovative behavior, in the manufacturing sector, only natural reward strategy and constructive thought strategy showed significant positive effects, while in the ICT sector, behavioral-oriented strategy, natural reward strategy, and constructive thought strategy all showed significant positive effects. Thirdly, in the analysis of the impact of self-leadership on job satisfaction, in the manufacturing sector, only natural reward strategy and constructive thought strategy showed significant positive effects, while in the ICT sector, behavioral-oriented strategy and natural reward strategy showed significant positive effects. Fourthly, in the analysis of the impact of job satisfaction on innovative behavior, significant positive effects were observed in both manufacturing and ICT sectors, with manufacturing sector having relatively greater impact than ICT sector. Lastly, the results of the analysis on the mediating effect of job satisfaction indicate that in the manufacturing sector, only a constructive thinking strategy significantly influences, showing partial mediating effects. However, in the ICT sector, no mediating effects of job satisfaction were observed for any sub-factors of self-leadership. These research findings highlight differences in the mechanisms of action of self-leadership on innovative behavior and its mediating effects between the manufacturing and ICT sectors. Furthermore, the results suggest the importance of improving organizational strategies and culture towards promoting leadership, job design, and job satisfaction, considering the characteristics of each industry and research and development organization.

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

The Mediating Effect of Experiential Value on Customers' Perceived Value of Digital Content: China's Anti-virus Program Market (경험개치대소비자대전자내용적인지개치적중개영향(经验价值对消费者对电子内容的认知价值的中介影响): 중국살독연건시장(中国杀毒软件市场))

  • Jia, Weiwei;Kim, Sae-Bum
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.2
    • /
    • pp.219-230
    • /
    • 2010
  • Digital content makes big changes to our daily lives while bringing opportunities and challenges for companies. Creative firms integrate pictures, texts, videos, audios, and data by digitalization to develop new products or services and create digital experiences to promote their brands. Most articles on digital content contribute to the basic concept or development of marketing it in literature. Actually, compared with traditional value chains for common products or services, the digital content industry seems to have more potential value. Because quite a bit of digital content is free to the consumer, price is not necessarily perceived as an indicator of the quality or value of information (Rowley 2008). It becomes evident that a current theme in digital content is the issue of "value," and research on customers' perceived value of digital content is a necessity. This article argues that experiential value has an advantage in customers' evaluations of digital content. Two different but related contributions to the understanding of "value" of digital content are made here. First, based on the comparison of digital content with products and services, the article proposes two key characteristics that make experiential strategy available for digital content: intangibility and near-zero reproduction cost. On top of that, based on the discussion of the gap between company's idealized value and customer's perceived value, this article emphasizes that digital content prices and pricing of digital content is different from products and services. As a result of intangibility, prices may not reflect customer value. Moreover, the cost of digital content in the development stage may be very high while reproduction costs shrink dramatically. Moreover, because of the value gap mentioned before, the pricing polices vary for different digital contents. For example, flat price policy is generally used for movies and music (Magiera 2001; Netherby 2002), while for continuous demand, digital content such as online games and anti-virus programs involves a more complicated matter of utility and competitive price levels. Digital content companies have to explore various kinds of strategies to overcome this gap. Rethinking marketing solutions such as advertisements, images, and word-of-mouth and their effect on customers' perceived value becomes essential. China's digital content industry is becoming more and more globalized and drawing special attention from different countries and regions that have respective competitive advantages. The 2008-2009 Annual Report on the Development of China's Digital Content Industry (CCIDConsulting 2009) indicates that, with the driven power of domestic demand and governmental policy support, the country's digital content industry maintained a fast growth of some 30 percent in 2008, obviously indicating the initial stage of industry expansion. In China, anti-virus programs and other software programs which need to be updated use a quarter-based pricing policy. Customers can download a trial version for free and use it for six months or a year. If they want to use it longer, continuous payment is needed. They examine the excellence of the digital content during this trial period and decide whether to pay for continued usage. For China’s music and movie industries, as a result of initial development, experiential strategy has not been much applied, even though firms in other countries find the trial experience and explore important strategies(such as customers listening to music for several seconds for free before downloading it). For the above reasons, anti-virus program may be a representative for digital content industry in China and an exploratory study of the advantage of experiential value in customer's perceived value of digital content is done in the anti-virus market of China. In order to enhance the reliability of the survey data, this study focused on people who were experienced users of anti-virus programs. The empirical results revealed that experiential value has a positive effect on customers' perceived value of digital content. In other words, because digital content is intangible and the reproduction costs are nearly zero, customers' evaluations are based heavily on their experience. Moreover, image and word-of-mouth do not have a positive effect on perceived value, only on experiential value. That is to say, a digital content value chain is different from that of a general product or service. Experiential value has a notable advantage and mediates the effect of image and word-of-mouth on perceived value. The results of this study help provide an understanding of why free digital content downloads exist in developing countries. Customers can perceive the value of digital content only by using and experiencing it. This is also why such governments support the development of digital content. Other developing countries whose digital content business is also in the beginning stage can make use of the suggestions here. Moreover, based on the advantage of experiential strategy, companies should make more of an effort to invest in customers' experience. As a result of the characteristics and value gap of digital content, customers perceive more value in the intangible digital content only by experiencing what they really want. Moreover, because of the near-zero reproduction costs, companies can perhaps use experiential strategy to enhance customer understanding of digital content.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Quantitative Assessment Technology of Small Animal Myocardial Infarction PET Image Using Gaussian Mixture Model (다중가우시안혼합모델을 이용한 소동물 심근경색 PET 영상의 정량적 평가 기술)

  • Woo, Sang-Keun;Lee, Yong-Jin;Lee, Won-Ho;Kim, Min-Hwan;Park, Ji-Ae;Kim, Jin-Su;Kim, Jong-Guk;Kang, Joo-Hyun;Ji, Young-Hoon;Choi, Chang-Woon;Lim, Sang-Moo;Kim, Kyeong-Min
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 2011
  • Nuclear medicine images (SPECT, PET) were widely used tool for assessment of myocardial viability and perfusion. However it had difficult to define accurate myocardial infarct region. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct size using polar map with adaptive threshold. Rat myocardial infarction model was induced by ligation of the left circumflex artery. PET images were obtained after intravenous injection of 37 MBq $^{18}F$-FDG. After 60 min uptake, each animal was scanned for 20 min with ECG gating. PET data were reconstructed using ordered subset expectation maximization (OSEM) 2D. To automatically make the myocardial contour and generate polar map, we used QGS software (Cedars-Sinai Medical Center). The reference infarct size was defined by infarction area percentage of the total left myocardium using TTC staining. We used three threshold methods (predefined threshold, Otsu and Multi Gaussian mixture model; MGMM). Predefined threshold method was commonly used in other studies. We applied threshold value form 10% to 90% in step of 10%. Otsu algorithm calculated threshold with the maximum between class variance. MGMM method estimated the distribution of image intensity using multiple Gaussian mixture models (MGMM2, ${\cdots}$ MGMM5) and calculated adaptive threshold. The infarct size in polar map was calculated as the percentage of lower threshold area in polar map from the total polar map area. The measured infarct size using different threshold methods was evaluated by comparison with reference infarct size. The mean difference between with polar map defect size by predefined thresholds (20%, 30%, and 40%) and reference infarct size were $7.04{\pm}3.44%$, $3.87{\pm}2.09%$ and $2.15{\pm}2.07%$, respectively. Otsu verse reference infarct size was $3.56{\pm}4.16%$. MGMM methods verse reference infarct size was $2.29{\pm}1.94%$. The predefined threshold (30%) showed the smallest mean difference with reference infarct size. However, MGMM was more accurate than predefined threshold in under 10% reference infarct size case (MGMM: 0.006%, predefined threshold: 0.59%). In this study, we was to evaluate myocardial infarct size in polar map using multiple Gaussian mixture model. MGMM method was provide adaptive threshold in each subject and will be a useful for automatic measurement of infarct size.