• 제목/요약/키워드: Soft-Threshold

검색결과 113건 처리시간 0.03초

Liquefaction and post-liquefaction behaviour of a soft natural clayey soil

  • Kheirbek-Saoud, Siba;Fleureau, Jean-Marie
    • Geomechanics and Engineering
    • /
    • 제4권2호
    • /
    • pp.121-134
    • /
    • 2012
  • The paper presents the results of identification, monotonous and cyclic triaxial tests on a potentially liquefiable soil from the Guadeloupe island. The material is a very soft clayey soil whose susceptibility to liquefaction is not clear when referring to index properties such as grain size distribution, plasticity, etc. The classifications found in the literature indicate that the material has rather a "clay-like" behaviour, i.e., is not very susceptible to liquefaction, but its properties are very close to the threshold values given by the authors. Cyclic triaxial tests carried out on the material under different conditions show that liquefaction is possible for a relatively important level of cyclic deviator or number of cycles. The second part of the paper is devoted to the study of the recovery of the soil after liquefaction and possibly reconsolidation. For the specimens tested without reconsolidation, that simulated the soil immediately after an earthquake, the recovery is nearly non-existent but the drop in pore pressure during extension results in a small available strength. On the contrary, after reconsolidation, the increase in strength of the liquefied specimens is quite large, compared to the initial state, but with unchanged failure envelopes.

시그모이드 추정과 임계 판정 가중 오차를 사용한 새로운 SDD 등화의 자기적응 성능 개선 (Self-Adaptive Performance Improvement of Novel SDD Equalization Using Sigmoid Estimate and Threshold Decision-Weighted Error)

  • 오길남
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.17-22
    • /
    • 2016
  • 고차 QAM 시스템에 대한 자기적응 등화에서 눈 모형이 완전히 닫힌 등화 초기에 적용하여 눈 모형을 빠르게 열뿐만 아니라 정상상태 오차 레벨을 크게 낮추는 새로운 SDD 알고리즘을 제안한다. 제안 방법은 M-QAM 응용에서, 관찰에 가장 인접한 두 심볼을 추정의 기반으로 함으로써 기존 SDD의 계산 복잡성을 최소화하고, QAM 차수에 무관하게 연판정을 크게 단순화하였다. 아울러 심볼 추정에 임계 함수에 비해 오판정 회피가 우수한 시그모이드 함수를 적용, 추정의 신뢰도를 높였다. 또한 등화기 갱신을 위한 오차 발생 시 임계 함수에 의한 심볼 판정 값을 오차에 가중하여 오차 변동 범위를 확장함으로써 제안한 자기적응 등화기의 초기화 성능을 개선하였다. 결과적으로 제안 방법은 기존 SDD의 계산 복잡성과 초기화 및 수렴 특성을 현저히 개선하였다. 부가 잡음이 존재하는 다중경로 채널 조건에서 64-QAM 및 256-QAM에 대한 모의실험을 통해 CMA와 제안한 2-SDD 및 가중된 2-SDD의 두 가지 형태의 성능을 비교하고 제안 방법의 유용성을 확인하였다.

이식형 심장 박동 조율기를 위한 저전력 심전도 검출기와 아날로그-디지털 변환기 (Low-Power ECG Detector and ADC for Implantable Cardiac Pacemakers)

  • 민영재;김태근;김수원
    • 전기전자학회논문지
    • /
    • 제13권1호
    • /
    • pp.77-86
    • /
    • 2009
  • 본 논문에서 이식형 심장 박동 조율기를 위한 심전도 검출기와 아날로그-디지털 변환기(ADC)를 설계한다. 제안한 웨이블렛 심전도 검출기는 웨이블렛 필터 뱅크 구조의 웨이블렛 변조기, 웨이블렛 합성된 심전도 신호의 가설 검정을 통한 QRS 신호 검출기와 0-교차점을 이용한 잡음 검출기로 구성된다. 저전력 소모의 동작을 유지하며 보다 높은 검출 정확도를 갖는 심전도 검출기의 구현을 위해, 다중스케일 곱의 알고리즘과 적응형의 임계값을 갖는 알고리즘을 사용하였다. 또한 심전도 검출기의 입력단에 위치하는 저전력 Successive Approximation Register ADC의 구현을 위해, 신호 변환의 주기 중, 매우 짧은 시간 동안에만 동작하는 비교기와 수동 소자로 구성되는 Sample&Hold를 사용하였다. 제안한 회로는 표준 CMOS $0.35{\mu}m$ 공정을 사용하여 집적 및 제작되었고, 99.32%의 높은 검출 정확도와 3V의 전원 전압에서 $19.02{\mu}W$의 매우 낮은 전력 소모를 갖는 것을 실험을 통해 확인하였다.

  • PDF

적응적 비선형 히스트그램 스트레칭을 이용한 의료영상의 화질향상 (Medical Image Enhancement Using an Adaptive Nonlinear Histogram Stretching)

  • 김승종
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.658-665
    • /
    • 2015
  • 의료영상에서 잡음을 제거하는 것과 명암대비를 좋게하는 것은 화질을 향상시키는 중요한 방법이다. 본 논문에서는 의료영상의 화질 향상을 위해 에지 기반 잡음 제거 방법과 적응적 비선형 히스토그램 스트레칭 알고리즘을 제안한다. 첫째, 웨이블릿 변환을 수행하고 분해된 고주파 부밴드 각각에 대해 Haar 변환을 수행한다. 동시에 수평, 수직, 대각 방향의 Sobel 마스크를 적용하여 방향별 에지를 검출한다. 둘째, 고주파 부밴드에 대해 에지 기반 적응적 문턱치를 이용하여 잡음을 제거한다. 셋째, 적응적 가중치를 이용하여 고주파 부밴드 계수 값을 향상한 후, Haar 역변환 및 웨이블릿 역변환을 수행하여 복원영상을 얻는다. 마지막으로 복원된 영상의 화소 값의 범위가 좁아졌으므로 제안하는 비선형 히스토그램 스트레칭 알고리즘을 이용하여 명암대비가 향상된 영상을 얻는다. 제안한 알고리즘을 낮은 명암대비를 갖는 의료영상에 적용했을 경우 효율적으로 에지를 보존하면서도 시각적으로 우수한 결과를 얻었다.

채널 오류율 추정에 기반을 둔 길쌈부호의 개선된 재구성 알고리즘 (An Improved Reconstruction Algorithm of Convolutional Codes Based on Channel Error Rate Estimation)

  • 성진우;정하봉
    • 한국통신학회논문지
    • /
    • 제42권5호
    • /
    • pp.951-958
    • /
    • 2017
  • 채널 재구성 기법이란 통신시스템에서 의도되지 않은 수신자가 수신 신호로부터 어떤 채널 부호가 사용되었는지, 주요 파라미터는 무엇인지를 알아내는 기법이다. 본 논문은 수신한 신호가 길쌈부호로 부호화된 경우, 사용된 길쌈부호의 주요파라미터인 입출력단의 비트수인 k와 n, 그리고 $k{\times}n$ 생성다항식행렬(Polynomial Generator Matrix, PGM)을 찾아내는 기법에 대해 다룬다. 본 논문은 M. Marazin 등이 제안한, 피버팅을 통한 가우스 조단소거법(Gauss Jordan Elimination Through Pivoting, GJETP)을 사용한 길쌈부호의 채널 재구성 기법에서 채널오류율과 무관하게 임계값을 설정해주던 것과 달리, 수신한 시퀀스로부터 2진 대칭 채널(Bynary Symetric Channel, BSC)의 채널오류확률을 추정하고 이로부터 임계값을 설정하는 방식을 제안하고, S. Shaojing 등의 연판정(soft decision) 값을 이용한 기법을 적용시켜서 채널 재구성 기법의 성공률을 향상시켰다.

웨이블릿 변환을 이용한 음향방출 신호의 처리기법 개선 및 위치표정 (Improvement of Acoustic Emission Signal Processing Method and Source Location using Wavelet Transform)

  • 김동현;박일서;정원용;박영석
    • 융합신호처리학회논문지
    • /
    • 제9권1호
    • /
    • pp.10-17
    • /
    • 2008
  • 본 논문은 설비진단에 있어 크랙 성장부터 누설에 이르기까지 결함으로 발생하는 AE 신호를 통하여 위치를 표정하여 진단 시스템의 오차를 줄이는 것이다. wavelet을 이용한 잡음 제거로서 위치표정의 개선을 제안하였고, 실험을 위한 신호원으로 알루미늄 평판에 샤프심 파단음을, 공기압축기의 누설음을 사용하였다. 신호원에 대하여 웨이블릿 Shrinkage방법과 Soft Threshold을 이용한 신호의 잡음제거 및 시간 도달차 법과 물성치를 적용한 속도 값으로 시뮬레이션을 통하여 위치표정 결과를 확인하였다. 그 결과 웨이블릿 변환을 이용한 잡음제거는 크랙실험의 경우 평균거리 10.46mm이하로 30% 이상과 누설 실험의 경우 평균필터에 비해 2%의 개선된 위치표정을 확인하였다.

  • PDF

Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Hwa-Young;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.111-119
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. Materials and Methods: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. Results: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements(P<.05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. Conclusion: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.

Effects of soft pellet creep feed on pre-weaning and post-weaning performance and intestinal development in piglets

  • Chen, Hao;Wang, Chunwei;Wang, You;Chen, Yilin;Wan, Meng;Zhu, Jiadong;Zhu, Aixia
    • Animal Bioscience
    • /
    • 제34권4호
    • /
    • pp.714-723
    • /
    • 2021
  • Objective: This study aimed to determine the effects of soft pellet creep feed (SPCF) on growth performance and intestinal development in piglets. Methods: A total of 18 sows and their litters of crossbred piglets (14±2 days, 3.73±0.72 kg) were assigned to one of three dietary groups receiving i) powder creep feed (PCF), ii) hard pellet creep feed (HPCF) or iii) SPCF during the pre-weaning period. After weaning, piglets were selected for continuous evaluation of the three diets on growth performance and intestinal health. Results: In the pre-weaning period, the average daily feed intake and average daily dry matter intake were significantly higher in the SPCF group than the HPCF group (p<0.05). In the post-weaning and entire experimental period, the different diets had no significant effect on growth performance. At 10 d after weaning, the serum glucose concentration was lower in the SPCF group (p<0.05) than the other groups; a higher (p<0.05) villus height and lower (p<0.05) crypt depth in the jejunum were also observed in the SPCF group than the other groups; Meanwhile, in the duodenum and jejunum, the SPCF group had a higher (p<0.05) villus height to crypt depth ratio than the other groups; Furthermore, the higher (p<0.05) threshold cycle values of lactic acid bacteria and lower (p<0.05) threshold cycle values of Clostridium, Enterobacter and Escherichia coli were also observed in the SPCF group, and the sucrase and maltase activity was higher (p<0.05) in the SPCF group than the other groups in duodenum and ileum. Conclusion: The SPCF improved pre-weaning feed intake and decreased the negative effects of weaning stress in the intestine in piglets.

무선 인지 시스템에서 협력 스펙트럼 센싱을 위한 최적화된 연판정 방식 (Optimal Soft Decision for Cooperative Spectrum Sensing in Cognitive Radio Systems)

  • 이소영;김진영
    • 한국전자파학회논문지
    • /
    • 제22권4호
    • /
    • pp.423-429
    • /
    • 2011
  • 협력 스펙트럼 센싱은 스펙트럼 센싱의 신뢰성 및 정확도를 높이기 위해 다수의 CR 기기들이 정보를 공유하여 면허 사용자를 검출하는 방식이다. 이때, CR 기기의 센싱 결과를 융합하는 방식에 따라 경판정 방식(hard decision method)과 연판정 방식(soft decision method)으로 구별할 수 있다. 본 논문은 면허 사용자와 CR 기기 사이의 거리에 따른 가중치가 적용된 결합 방식(Distance based Weight Combining: DWC)을 사용하여 에너지 검출기반 협력 스펙트럼 센싱을 제안하고, 이에 따른 분석 및 모의 실험 결과를 나타낸다. 면허 사용자의 신호는 OFDM 기반의 시스템을 가정하였으며, 면허 사용자와 CR 기기 사이의 무선 채널은 가우시안(Gaussian) 채널로 모델링하였다. 에너지 검출법을 위한 임계값은 각 채널의 SNR(Signal to Noise Ratio)에 따라 다르게 적용되었으며, 각 채널의 잡음 신호의 평균값으로 가정하였다. DWC를 적용한 협력 스펙트럼 센싱을 수행한 결과, 거리에 따라 다양한 검출 확률을 나타낸 단일 센싱에 비해 비교적 안정된 검출 확률을 나타내는 것으로 알 수 있었으며, 동일 이득 결합을 반영하여 협력 스펙트럼 센싱을 수행한 것보다 우수한 스펙트럼 센싱을 나타내었다.

전기미각측정기를 이용한 재발성 아프타성 궤양 환자의 미각평가 (Evaluation of Taste in the Patients with Recurrent Aphthous Ulceration by Electrogustometer)

  • 전진용;안용우;고명연
    • Journal of Oral Medicine and Pain
    • /
    • 제32권1호
    • /
    • pp.1-8
    • /
    • 2007
  • 1. 서론 : 미각 장애는 신체적, 정신적 건강의 유지에 매우 중요한 문제라 할 수 있으며 국소적 병소나 전신적 질환의 한 증상으로 나타나는 경우가 많기 때문에 질병의 진단에 좋은 참고 자료를 제공하기도 한다. 미각역치검사는 검사방법에 따라 화학용액법과 전기미각측정법으로 나눌 수 있는데 이중 전기미각측정법이 자주 사용된다. 전기미각측정법을 이용하여 전신적, 환경적 요인을 고려한 연구가 다양하게 진행되었으나 구강내 병소와 관련된 미각의 연구는 불충분 하였다. 이에 구강내 질환중 가장 자주 발생하는 RAU와 미각과의 상관관계를 알아보고자 한다. 2. 연구대상 및 방법 : 부산대학교병원 구강내과에 내원한 환자 중에 구강검사를 통해 재발성 구내궤양으로 진단된 환자 27명을 실험군으로 선택하고, 인천 소재 00치과의원에 내원한 치과환자 중에 미각에 영향을 미칠 수 있는 전신질환, 약물복용, 구강내 연조직 질환을 가지고 있지 않는 환자 70명을 대조군으로 선택하였다. 전기미각측정기(Electrogustometer, Model EG-2B, Nagashima Medical Instrument Co., Nagashima, Japan)를 사용하여 오른쪽 혀끝, 측방 중앙부위, 유곽유두 근처부위, 연구개 부위에서 미각역치 측정을 시행하였다. 연구대상자는 왼손에 전기 미각측정기의 부저를, 오른손에 음극을 잡도록 하였다. 검사자는 양전극을 피검자의 측정하고자 하는 부위에 위치시킨 후 전류강도를 낮은 수치에서부터 점점 증가시켰다. 각 부위에서 5분 간격으로 2회 측정한 다음, 평균치를 구하여 그 부위에 대한 전기미각역치로 정하였고, 측정단위는 dB로 하였다. 재발성 구내궤양 환자들은 진단이 되었을 때 미각역치를 측정하고, 1회 치료 후 한 번 더 측정하여 비교하였다. 34dB에서 느끼지 못하는 연구대상자들의 전기미각역치는 34dB로 기록하였고, 재발성 구내궤양 환자인 실험군에서는 구강증상의 변화를 Numerical Analougue Scale(NAS)로 평가하였다. 3. 결론 : 1. 재발성 구내궤양 환자군에서 대조군에 비해 전기미각역치는 매우 낮았다. 2. 여성에서는 재발성 구내궤양 환자군에서 전기미각역치가 매우 낮았으며, 남성에서는 연구개를 제외한 전 부위에서 낮았다. 3. 재발성 구내궤양 환자군의 구내병소가 단일병소일 경우보다 복수 병소일 경우에 미각역치가 더 높은 경향을 보였다. 4. 재발성 구내궤양 환자군의 만성도에 따른 비교에서는 만성환자군에서 혀끝, 유곽유두부위, 연구개 부위에서 높은 경향을 보였으며 급성환자군에서는 혀 측방중앙부위에서 높은 경향을 보였다. 5. 재발성 구내궤양 환자군의 치료에 따른 전기미각역치는 혀끝, 혀 측방중앙부위, 유곽유두부위에서 유의하게 상승하였고 연구개에서는 상승하는 경향을 보였으며 NAS는 감소하는 경향을 보였다.