• Title/Summary/Keyword: Soft Surface

Search Result 975, Processing Time 0.029 seconds

Effect of Milling Speed on the Structural and Magnetic Properties of Ni70Mn30 Alloy Prepared by Planetary Ball Mill Method

  • Hussain, Imad;Lee, Ji Eun;Jeon, So Eun;Cho, Hyun Ji;Huh, Seok-Hwan;Koo, Bon Heun;Lee, Chan Gyu
    • Korean Journal of Materials Research
    • /
    • v.28 no.10
    • /
    • pp.539-543
    • /
    • 2018
  • We report the structural, morphological and magnetic properties of the $Ni_{70}Mn_{30}$ alloy prepared by Planetary Ball Mill method. Keeping the milling time constant for 30 h, the effect of different ball milling speeds on the synthesis and magnetic properties of the samples was thoroughly investigated. A remarkable variation in the morphology and average particle size was observed with the increase in milling speed. For the samples ball milled at 200 and 300 rpm, the average particle size and hence magnetization were decreased due to the increased lattice strain, distortion and surface effects which became prominent due to the increase in the thickness of the outer magnetically dead layer. For the samples ball milled at 400, 500 and 600 rpm however, the average particle size and hence magnetization were increased. This increased magnetization was attributed to the reduced surface area to volume ratio that ultimately led to the enhanced ferromagnetic interactions. The maximum saturation magnetization (75 emu/g at 1 T applied field) observed for the sample ball milled at 600 rpm and the low value of coercivity makes this material useful as soft magnetic material.

Dependence of Gas Sensing Properties of Embossed TiO2 Thin Films on Links Between Hollow Hemispheres (엠보싱 TiO2 박막에서 링크 형상 제어에 따른 가스 감도 변화)

  • Moon, Hi-Gyu;Park, Hyung-Ho;Yoon, Seok-Jin;Jang, Ho-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.8
    • /
    • pp.639-645
    • /
    • 2012
  • Embossed $TiO_2$ thin films with high surface areas are achieved using soft-templates composed of monolayer polystyrene beads. The form of links between the beads in the templates is controlled by varying the $O_2$ plasma etching time on the templates, resulting in various templates with close-linked, nano-linked, and isolated beads. Room-temperature deposition of $TiO_2$ on the plasma-treated templates and calcination at $550^{\circ}C$ result in embossed films with tailored links between anatase $TiO_2$ hollow hemispheres. Although all the embossed films have similar surface areas, the sensitivity of films with nano-linked $TiO_2$ hollow hemispheres to 500 ppm CO and ethanol gases are much higher than that of films with close-linked and isolated hollow hemispheres, and the detection limits of them are as low as 0.6 ppm for CO and 0.1 ppm for ethanol. The strong correlation of sensitivity with the form of links between hollow hemispheres reveals the critical role of potential barriers formed at the links. The facile, large-scale, and on-chip fabrication of embossed $TiO_2$ films with nano-linked hollow hemispheres on Si substrate and the high sensitivity without the aid of additives give us a sustainable competitive advantage over various methods for the fabrication of highly sensitive $TiO_2$-based sensors.

Bedding Fabric Performance Using Polyester, Tencel and Cotton MVS Blended Spun Yarns (PET, Tencel, Cotton MVS 혼방사로 제직된 침구용 직물의 성능평가)

  • Sa, A-Na;Lee, Jung Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.1
    • /
    • pp.17-27
    • /
    • 2017
  • This study evaluated the performance of bedding fabrics consisting of warp (150d/144f, polyester) and weft (polyester, Tencel and cotton MVS blended spun yarn) with blend ratio of weft. We measured electrostatic propensity, moisture properties, pilling properties and mechanical properties of the fabrics for this study. F-P fabric showed outstanding moisture properties and pilling properties. However, tensile properties and electrostatic propensity were relatively inferior to other characteristic values. Significant static electricity may make F-P fabric uncomfortable. F-P7C3 fabric showed outstanding moisture properties and pilling properties. Static electricity may make F-P7C3 fabric uncomfortable; in addition, F-P5C5 fabric showed outstanding moisture properties and pilling properties. Rough and stiff hand feel were expected to increase because tensile properties decreased and surface properties increased. F-C fabric showed outstanding pilling properties and electrostatic propensity. However, it showed inferior moisture control properties. F-P5T4C1 fabric showed outstanding moisture properties, pilling properties and electrostatic propensity. Several properties are outstanding; however, the hand feels are very rough and stiff from bending. The water evaporation and static electricity increased with increasing polyester content. As the content of cotton increased, tensile properties were improved. However, water evaporation and static electricity decreased. The addition of Tencel increased the thickness and compression energy so that it exhibited a soft characteristic upon compression and an excellent moisture control properties, but the surface became somewhat coarse.

Evaluation of Usefulness in New Immobilization Device with 3D CT Angiography for Lower Extremity (전산화단층촬영검사에서 하지의 3D 혈관조영검사를 위한 새로운 고정기구의 유용성 평가)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.184-191
    • /
    • 2007
  • Our objective was to develop and evaluate a non-invasive device for rigid immobilization and surface disease non-contact of the table in the lower extremity during CT angiography. The immobilization device consists of two components. The patient's lower limb device stabilizing elements made of polyethylene resin soft materials, and pelvis parts foam pad is used for non-contact surface. In a Prospective study the lower extremity device was used in patients who underwent a CT angiography of the lower limb. Immobilization with our device was well tolerated by all patients. The quality of the resulting images in the popliteal and infrapopliteal region was rated by five-point scale. The rigid immobilization resulted in a complete absence of motion artifacts. The new device is an effective, well tolerated and easily used immobilization that is suitable of use in 3D lower extremity CT angiography.

Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients (일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교)

  • Seok, Hyo Hyun;Kwon, Geun-Yong;Baek, Seung-Hak;Choi, Tae Hyun;Kim, Sukwha
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

Design of a New Applicator for High-Dose Rate Vaginal Brachytherapy (고선량율 질강 근접조사를 위한 새로운 적용구의 제작)

  • Shin, Sei One
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.123-128
    • /
    • 2000
  • Purpose: This study was aimed to develop a new vaginal applicator(Shin's Applicator) for 2-channel high-dose rate vaginal brachytherapy to evaluate uniformity of surface dose, and to present 3-dimensional dose distribution of the applicator. Methods: Shin's Applicator was inexpensively constructed using human soft tissue equivalent acrylic bar. We evaluated dose uniformity along the applicator surface using film densitometer and performed vaginal intracavitary brachytherapy after insertion of the applicator using HDR brachytherapy planning software and brachytherapy unit(Ralstron-20B). Results: Shin's Applicator allows improved dose distribution than the existing 1-channel cylinder and achieves diminished urinary bladder and rectal dose by 20%. Conclusions: From the above results, it can be concluded that Shin's Applicator may be an improved form of a vaginal applicator. Furthermore, it can be suggested that this applicator has an advantage, for it prevents vaginal stenosis after radiation therapy and can be used as a disposable vaginal dilator. Further follow up examination with radiological study may be helpful to evaluate the therapeutic efficacy of this applicator.

  • PDF

A Study on the Suitability of the Mohr-Coulomb Model for Numerical Analysis of Ground Excavation (지반굴착 시 Mohr-Coulomb 모델 적합성에 관한 수치해석적 분석)

  • Lee, Jonghyun;Jin, Hyunsik;An, Joonsang;Baek, Yong;Yoon, Hyeongsuk
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.1-15
    • /
    • 2020
  • The Mohr-Coulomb model is mainly used in evaluating the behavior of the ground in numerical analyses of domestic ground excavation. This study analyzes its limitations and compares its numerical results with the hyperbolic model, a model that closely follows actual ground behavior during excavation. Recent applications of the Mohr-Coulomb model in Korea have tended to impose arbitrary special boundary conditions to control the problem of excessive heaving of the ground excavation surface. This adjustment only controls the size of the heaving of the excavation surface, implying that the ground behavior is distorted from the actual behavior. This study compares results from the hyperbolic model (hardening soil model) and the Mohr-Coulomb model, and confirms that the hyperbolic model provides both a more-suitable solution to the problem of heaving during excavation and the actual stress-strain behavior. In numerical analyses of ground excavation, the hyperbolic model is expected to give results consistent with the actual ground behavior.

Characteristics of Tidal Beach and Shoreline Changes in Chonsu Bay, West Coast of Korea (한반도 서해 천수만의 해안선 변화 및 조간대 해빈 특성)

  • Ryu Sang-Ock;Chang Jin-Ho
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.584-596
    • /
    • 2005
  • Morphology, surface sediments, sedimentation rates and sea-cliff erosion have been monitored, for one year to investigate the shoreline changes and tidal beach characteristics in Cheonsu Bay along the west coast of Korea. The seacliff of the bay consists of intensively weathered sedimentary rocks and soft soil, showing an erosion range of $-58.9\~73.3cm/yr$ by a weak wave forcing. Active sea-cliff erosions are recognized by peculiar geomorphic features, including saw teeth-shaped coastline, gravels, relict weathered basement-rock and 'Island Stack' exposed on the high-tide beach surface. The beach sediments show low compositional maturity at the south and north headlands and gradually high towards the central part. This observation seems to be caused by the fact that beach sediments are to originate from the both headlands in the study area and then transported by long-shore current associated with a wave action.

Characteristics of Bovine Lymphoma Caused by Bovine Leukemia Virus Infection in Holstein-Friesian Dairy Cattle in Korea

  • Yoon, S.S.;Bae, Y.C.;Lee, K.H.;Han, B.;Han, H.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.5
    • /
    • pp.728-733
    • /
    • 2005
  • The frequency and distribution of lymphoma caused by bovine leukemia virus (BLV) infection in various organs were investigated. Lymphoma samples were obtained from slaughtered cattle or from cattle submitted to the National Veterinary Research and Quarantine Service, Korea. Thirty female Holstein-Friesian dairy cattle aged over three years with the BLV-associated lymphoma were studied. None of the Korean native cattle (Hanwoo) had lymphoma in this study however. Lymphoma tissues were gray to pink in color, soft in consistency, and bulged from the cut surface. In advanced lymphoma tissues, there was great variety in the appearance of involved structures due to hemorrhage, necrosis, and/or calcification. Neoplastic tissues were observed in lymph nodes in all lymphoma cases. Intestine (96.4%), heart (88.9%), stomach (73.1%), and diaphragm (62.5%) were frequently involved with lymphoma. However, there was no lymphoma detected in liver. Large neoplastic masses, sometimes reaching the size of over 20 cm, were found in the abdominal cavities. It is suggested that metastasis of lymphomas occurs mainly via lymph based on gross observations; neoplasia may have been initiated in the serosal surface of the lung, heart, peritoneum, and numerous hollow organs in the abdominal cavity. Also many organs in the abdominal and thoracic cavity were affected by neoplastic tissues simultaneously. Characteristics observed in this study could be used as criteria to differentiate BLV-associated lymphoma from other nodular lesions in the slaughterhouse and as fundamental data to make clear the mechanism of metastasis or pathogenesis of EBL.

Development of KAU Mechanical Lunar Simulants and Drop Test of Lunar Landing Gears (KAU 기계적 달 복제토 개발 및 달착륙선 착륙장치의 낙하시험)

  • Yoo, Seok-Ho;Kim, Hyun-Duk;Lim, Jae Hyuk;Park, Jung-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.12
    • /
    • pp.1037-1044
    • /
    • 2014
  • In this study, we designed a drop test system considering lunar surface environment and tested landing gear of experimental lunar lander. The lunar lander would be landed at soil place for soft landing. When the lunar lander touches down, the acceleration of the lander is largely affected by mechanical characteristics of the lunar soil. Accordingly, a drop test using lunar soil is needed to verify the performance of the lunar landing gear. Because the lunar soil is not available generally, we developed a lunar simulant KAUMLS(Korea Aerospace University Mechanical Luna Simulant) based on mechanical properties of the lunar soil of NASA's LUNA PROJECT. In addition, drop tests on steel plate and dry sand are performed to evaluate impact characteristics by the surface environment.