• Title/Summary/Keyword: Soft Starting Technique

Search Result 10, Processing Time 0.022 seconds

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

Comparison of Starting Current Characteristics for Three-Phase Induction Motor Due to Phase-control Soft Starter and Asynchronous PWM AC Chopper

  • Thanyaphirak, Veera;Kinnares, Vijit;Kunakorn, Anantawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1090-1100
    • /
    • 2017
  • This paper presents the comparison of starting current characteristics of a three-phase induction motor fed by two types of soft starters. The first soft starter under investigation is a conventional AC voltage controller on the basis of a phase-control technique. The other is the proposed asynchronous PWM AC chopper which is developed from the conventional synchronous PWM AC chopper. In this paper, the proposed asynchronous PWM AC chopper control scheme is developed by generating only two asynchronous PWM signals for a three-phase main power circuit (6 switching devices) from a single voltage control signal which is compared with a single sawtooth carrier signal. By this approach, the PWM signals are independent and easy to implement since the PWM signals do not need to be synchronized with a three-phase voltage source. Details of both soft starters are discussed. The experimental and simulation results of the starting currents are shown. It is found that the asynchronous PWM AC chopper efficiently works as a suitable soft starter for the three-phase induction motor due to that the starting currents are reduced and are sinusoidal with less harmonic contents, when being compared with the starting current waveforms using the conventional phase-control starting technique. Also the proposed soft starter offers low starting electromagnetic torque pulsation.

Design of a Electronic Ballast using Microprocessor (마이크로 프로세서를 이용한 전자식 안정기 설계)

  • Lee, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.44-52
    • /
    • 2007
  • In this study, design and control method using low cost Micro-controller(MCU) for inverter driving circuit in fluorescence lamp is presented. Soft starting technique is adopted to reduce switching loss and moment deterioration which are induced by high speed switching frequency in inverter ballast. Performance of the ballast stabilizer and the lighting characteristic of the fluorescence lamp have been improved by stabilizing switching pulses through the Pulse Width Modulation control.

Design and Control of SRM For LSEV Drive

  • Lee, Hee-Chang;Lee, Man-Hyung;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.96-101
    • /
    • 2004
  • This paper presents an application of SRM drive for LSEV(Low Speed Electric Vehicle). In this paper, a 5〔㎾〕 SRM for a traction of a LSEV is to design and investigate the characteristics of the drive system. The main design parameters and control strategy are given. In the control method, a current control, for the soft-starting technique at a starting operation, is adopted. In the high speed range, an angle control technique is implemented, for a high efficiency drive of SRM. Some experimental tests are executed to find the drive performances.

NON CONVENTIONAL METHOD FOR SOFT STARTING OF THREE PHASE INDUCTION MOTORS

  • Ahmed Nabil A.;Kim Sung-Jun;Suh Ki-Young;Kown Soon-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.27-31
    • /
    • 2004
  • This paper presents a nonconventional method for oft starting of three-phase induction motors, which achieved by flux weakening technique. flux weakening is not done by reducing the applied voltage as in the conventional methods, Flus weakening is achieved y increasing the supply frequency over the rated value while the voltage amplitude is kept constant. This method has advantage of reducing the stress on the electrical and mechanical systems. The feasibility of this basic idea has been confirmed through investigating the starting transient corresponding to this mode of operation. For this purpose, a rigorous state space mathematical model has been developed and simulated. The validity of the proposed method through the results from the mathematical model have been confirmed experimentally.

  • PDF

A Novel Position Sensorless Speed Control Scheme for Permanent Magnet Synchronous Motor Drives

  • Won, Tae-Hyun;Lee, Man-Hyung
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.125-132
    • /
    • 2002
  • PMSMS (permanent magnet synchronous motors) are widely used in industrial applications and home appliances because of their high torque to inertia ratio, superior power density, and high efficiency. For high performance control, accurate informations about the rotor position is essential. Sensorless algorithms have lately been studied extensively due to the high cost of position sensors and their low reliability in harsh environments. A novel position sensorless speed control for PMSMs uses indirect flux estimation and is presented in this paper. Rotor position and angular velocity are estimated by the proposed indirect flux estimation. Linkage flux and magnetic field flux are calculated by the voltage equations and the measured phase current without any integration. Instead of linkage flux calculation with integral operation, indirect flux and differential magnetic field are used for the estimation of rotor position. A proper rejection technique fur current noise effect in the calculation of differential linkage flux is introduced. The proposed indirect flux detecting method is free from the integral rounding error and linkage flux drift problem, because differential linkage flux can be calculated without any integral operation. Furthermore, electrical parameters of the PMSM can be measured by the proposed TCM (time compression method) for soft starting and precise estimation of rotor position. The position estimator uses accurate electrical parameters that are obtained from the proposed TCM at starting strategy. In the operating region, a proper compensation method fur temperature effect can compensate fir the estimation error from the variation of electrical parameters. The proposed novel position sensorless speed control scheme is verified by the experimental results.

Treatment of Distal Tibial Metaphyseal Fracture Using MIPPO Technique (MIPPO 수기를 이용한 원위 경골 골간단 골절의 치료)

  • Lee, Ho-Seung;Kim, Jung-Jae;Oh, Se-Kwan;Ahn, Hyung-Sun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.166-170
    • /
    • 2004
  • Purpose: To evaluate the results of MIPPO (minimal invasive percutaneous plate osteosynthesis) technique for distal tibial metaphyseal fractures. Materials and Methods: It is a retrospective study of 13 patients who were treated by MIPPO technique for distal tibial metaphyseal fractures from Jan. 2001 to Jan. 2003. The average age was 46.7 years and mean follow-up period was 13.3 months. According to AO classification, there were 8 cases of A1, 3 cases of A2, 1 case of B1 and 1 case of C2. One case of A1 was a Gustilo-Anderson type I open fracture and fibular fractures were combined in 12 cases. We applied anatomical reduction and internal fixation for the fibular fractures and internal fixation on the medial side of the tibia by MIPPO technique for distal tibial metaphyseal fractures. Clinical results were evaluated using radiographic results, Neer score, the starting time of postoperative exercise and clinical complications. Results: According to the Neer score, all cases showed satisfactory results. Active ankle ROM was started at average 2.4 weeks ($2{\sim}4$ weeks) and full weight bearing ambulation at average 5.2 weeks ($4{\sim}8$ weeks) postoperatively. Union of fractures was obtained by average 14.4 weeks ($8{\sim}18$ weeks) postoperatively. Two cases showed $5^{\circ}$ limitation of motion without functional deficits and other cases showed satisfactory ROM results. One case had $6^{\circ}$ valgus deformity without functional deficits. There were not any other complications like soft tissue problems and delayed-or non-union. Conclusion: MIPPO technique for the treatment of distal tibial metaphyseal fractures is a feasible technique with a good clinical outcomes.

  • PDF

Fast Consolidation Test Using Seepage Forces : Method and Validation (침투압을 이용한 급속압밀시험 : 방법 및 검증)

  • Lee, Kang-Il;Kim, Tae-Hyung;Znidarcic, Dobroslav
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.4
    • /
    • pp.31-38
    • /
    • 2009
  • A continuous, fast, and convenient experimental method, replacing recent tests such as standard oedometer or self weight consolidation test, is needed for the determination of the consolidation behavior of unformed soft soils. This study introduced the seepage induced fast consolidation test using the flow pump technique. It can obtain the consolidation characteristics of unformed soft soils conveniently and fast. The seepage induced consolidation test apparatus consists of a modified triaxial cell, differential pressure transducer, flow pump, and displacement transducer. The test continuously proceeds with starting seepage forces induced consolidation, loading consolidation, and permeability test on the same sample. In addition, this test result was compared with the standard oedometer test result to make this method valid. From this study it was found that this method is a convenient and time saving effective method for obtaining data required for calculation of consolidation settlement of unformed soft soils.

Evaluation of Subgrade Stiffness after Microtunnelling Operations at JFK Airport by Crosshole and SASW Tests (마이크로터널링으로 인한 활주로 기층의 전단 강성의 변화 : 크로스흘 시험과 SASW 실험에 의한 평가)

  • 조성호
    • Geotechnical Engineering
    • /
    • v.14 no.2
    • /
    • pp.67-78
    • /
    • 1998
  • Microtunnelling is a technique applied to install a small-size tunnel in a soft cohesionless ground. In microtunnelling, a series of concrete tubular segments are pushed from a starting pit to power-line tunnel under a runway of JFK international airport at New York. During the microtunneling process, bentonite is jetted with very hyh pressure through a nozzle to advance disturbance in the subgrade caused by the pressurized bentonite in the aspects of subgrade stiffness. SASW measurements were performed on the runway above the center line of the shear wave velocity profiles. Besides the change of subgrade stiffness, the change of subgrade strength was also evaluated by the site-specific relationships between shear wave velocity and N value, which was determined by N values. The estimated N values gave a clue to the understanding of the change of subgrade strength.

  • PDF