• Title/Summary/Keyword: Soft Laser

Search Result 139, Processing Time 0.024 seconds

Burn Wound Successfully Treated with 830-nm Light Emitting Diode Phototherapy Combined with Epidermal Growth Factor Solution

  • Lee, Hae-Jin;Kim, Young Koo
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.94-96
    • /
    • 2019
  • Burns are one of the most extensive injuries of soft tissues as well as skin, occasionally resulting in extensive, deep wounds and death. Burn wounds can lead to severe physical and psychological distress because of excessive scarring and skin contractures. Treatment of burn wounds has always been a challenging problem and many different methods have been used to treat such injuries. We report here on treating a patient with a burn wound using 830-nm light emitting diode (LED) phototherapy combined with epidermal growth factor (EGF) solution. After five daily sessions of LED with EGF solution treatment, the patient demonstrated nearly complete improvement with no remarkable side effects. We suggest that LED phototherapy combined with EGF solution could be an effective and safe treatment option for treating burn wounds.

Percutaneous Endoscopic Thoracic Discectomy : Posterolateral Transforaminal Approach

  • Lee, Ho-Yeon;Lee, Sang-Ho;Kim, Dong-Yun;Kong, Byoung-Joon;Ahn, Yong;Shin, Song-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.58-62
    • /
    • 2006
  • Objective : Development of diagnostic tools has resulted in early detection of thoracic disc herniations[TDH] even when the herniated disc is soft in consistency. In some of the cases, it is considered better not to opt for surgical treatment due to the unduly high morbidity and potential complications associated with conventional approaches. The authors have applied percutaneous endoscopic thoracic discectomy[PETD] technique to soft TDHs in order to avoid the morbidity associated with conventional approaches. Methods : Eight consecutive patients [range, 31 to 75 years] with soft lateral or central TDH [from T2-3 to T11-12] underwent PETD between May 2001 and June 2004. The patient was positioned in a prone position with intravenous sedation and local anesthetic infiltration. The authors introduced a cannula into the thoracic intervertebral foramen using endoscopic foraminoplasty technique. Discectomy was performed with mechanical tools and a laser under continuous endoscopic visualization and flu oroscopic guidance. Functional status was assessed preoperatively and postoperatively using the Oswestry Disability Index[ODI]. Results : The mean ODI scores improved from 52.8 before the surgery to 25.8 at the final follow-up. In cases of myelopathy, long tract signs showed improvement. The mean operative time was 55 minutes, and no patient required conversion to open surgery. Conclusion : The technique allows a smaller incision and less morbidity. Soft TDH is amenable to this minimally invasive approach in selected patients with myeloradiculopathy.

Lasing Effects on the Dorsal Tongue Mucosa of Adult Rats by Pulsed Nd:YAG Laser (펄스식 Nd:YAG 레이저 조사에 따른 성체 흰주 혀배면 점막의 변화)

  • Jung-Ho Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.183-196
    • /
    • 1996
  • The author examined the clinical and histological changes on the dorsal tongue mucosa of adult Sprague-Dawley rats after lasing by pulsed Nd:YAG laser. The dorsal tongue was lased for 3 seconds by 1.5, 2.0, 2.5, 3.0, 3.5, 4.0W and 10, 15, 20, 20pps. After tissue changes were observed clinically, the excised samples were observed histologically and the width of tissue destruction was analyzed quantitatively under the Confocal laser microscope respectively. The following results were obtained : 1. Whitening of peripheral tissue was observed more as increasing pulsed per second (Hz) below power 2.5W and observed at all parameters above power 3.0W. 2. Charring of mucosal surface was observed at all parameters but mild at parameters below power 2.0W. 3. The destruction of epithelium was observed at all parameters and tissue destruction was extended to lamina propria at higher pulses per second. 4. The width of tissue destruction was more widening as increasing energies per pulse (p<0.001) and the narrowest at 20Hz than 10Hz, 15Hz and 30Hz(p<0.05). As the above results, author suggests power below-3.5W and 20Hz as the lasing parameters for oral soft tissue therapy.

  • PDF

The Effect of H content in Si Precursor on the Performance of Poly-Si Crystallized by Pulsed YAG2${\omega}$ Laser on Soft Substrate

  • Li, Juan;Ying, Yao;Meng, Zhiguo;Chunya, Wu;Xiong, Shaozhen;Kwok, Hoi-Sing
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1604-1607
    • /
    • 2009
  • YAG laser crystallization of Si-based thin film deposited on plastic substrate has been studied. The Si-based thin films as crystallization precursor are with varied hydrogen (H) content. The effect of the H content on the crystallinity of the resulted poly-Si film has been investigated. The experimental results of the poly-Si crystallized by doublefrequency YAG laser shows that the initial dehydrogenation process could be left out if ${\mu}c$-Si was adopted as the crystallization precursor. The YAG laser annealing condition on plastic substrate and the crystallization results have been discussed in the paper.

  • PDF

Recent development of polymer optical circuits for the next generation fiber to the home system

  • Kaino, Toshikuni
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.13-14
    • /
    • 2006
  • The use of soft-lithography instead of standard photolithography and dry etching technologies is attractive because inexpensive optical device can be realized. Polymerization using multi-photon absorption of materials is also a good method for optical waveguide fabrication. Laser induced self-writing technology of optical waveguide is also very simple and attractive. Using these processes, we can fabricate and interconnect optical circuits at once. In this presentation, several simple fabrication methods will be introduced. New optical loss evaluation method for polymer optical waveguides will also be presented

  • PDF

Comparison of Mechanical properties and Surface Friction of White Metals Produced by Centrifugal and Laser Cladded on SCM440 (원심주조방식과 레이저 클래딩 증착법을 통한 화이트메탈의 기계 및 마찰특성 비교)

  • Jeong, Jae-Il;Kim, Dong-Hyuk;Park, Jin-Young;Oh, Joo-Young;Choi, Si-Geun;Kim, Seock-Sam;Cho, Young Tae;Lee, Ho;Ham, Seung-Sik;Kim, Jong-Hyoung
    • Tribology and Lubricants
    • /
    • v.34 no.3
    • /
    • pp.84-92
    • /
    • 2018
  • Bearings are essential for reducing vibration and wear, in order to achieve high durability and increase longevity. White metal treatment of tilting pads via centrifugal casting method has the possibility of increasing durability. However, this manufacturing method has drawbacks such as long processing time, high defect rate, and harmful health effects. Laser cladding deposition technique is a powerful method that can address these issues by decreasing the processing time and providing good adhesion. In this study, we suggest optimum conditions for laser cladding deposition that can be used in industrial applications. We deposited a soft white metal layer on SCM440 that is primarily used in shafts to minimize wear of bearing pads. During the laser deposition process, we controlled factors such as laser power, powder feed rate, and laser head speed to determine the optimum conditions. In addition, we measured the hardness using micro Vickers, and performed field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, and friction tests to investigate the mechanical properties and surface characteristics for different parameters. Based on the experimental results, we suggest that laser power, powder feed rate, and laser head speed of 1.3 kW, 2.5 rpm, and 10 mm/s, respectively, constitute the optimum conditions for producing white metals using laser cladding.

A study of facial soft tissue of Korean adults with normal occlusion using a three-dimensional laser scanner (3차원 레이저 스캐너를 이용한 한국 성인 정상교합자의 안면 연조직에 대한 연구)

  • Baik, Hyoung-Seon;Jeon, Jai-Min;Lee, Hwa-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.14-29
    • /
    • 2006
  • Developments in computer technology have made possible the 3-dimensional (3-D) evaluation of hard and soft tissues in orthodontic diagnosis, treatment planning and post-treatment results. In this study, Korean adults with normal occlusion (male 30, female 30) were scanned by a 3-D laser scanner, then 3-D facial images formed by the Rapidform 2004 program (Inus Technology Inc., Seoul, Korea.). Reference planes in the facial soft tissue 3-D images were established and a 3-D coordinate system (X axis-left/right, Y axis-superior/inferior, Z axis-anterior/posterior) was established by using the soft tissue nasion as the zero point. Twenty-nine measurement points were established on the 3-D image and 43 linear measurements, 8 angular measurements, 29 linear distance ratios were obtained. The results are as follows; there were significant differences between males and females in the nasofrontal angle $(male:\;142^{\circ},\;female:\;147^{\circ})$ and transverse nasal prominence $(male:\;112^{\circ},\;female:\;116^{\circ})$ (p<0.05). The transverse upper lip prominence was $107^{\circ}$ in males, $106^{\circ}$ in females and the transverse mandibular prominence was $76^{\circ}$ in both males and females. Li-Me' was 0.4 times the length of Go-Me'(mandibular body length) and the mouth height was also 0.4 times the width of the mouth width. The linear distance ratio from the coronal reference plane of FT, Zy, Pn, ULPm, Li, Me' was -1/-1/1/0.5/0.5/-0.6 respectively. The 3-D facial model of Korean adults with normal occlusion were be constructed using coordinate values and linear measurement values. These data may be used as a reference in 3-D diagnosis and treatment planning for malocclusion and dentofacial deformity patients and applied for 3-D analysis of facial soft tissue changes before and after orthodontic treatment and orthognathic surgery.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm)difference of skin excessive expense $CO_2$ Laser (피부과용$CO_2$ 레이저의 공극(1.0mm및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성 연구)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methods

  • Kaleli, Necati;Ural, Cagri;Us, Yesim Olcer
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.124-130
    • /
    • 2020
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of sintering procedures on marginal discrepancies of fixed partial metal frameworks fabricated using different sintering-based computer-aided design and computer/aided manufacturing (CAD/CAM) techniques. MATERIALS AND METHODS. Forty resin die models of prepared premolar and molar abutment teeth were fabricated using a three-dimensional (3D) printer and divided into four groups (n = 10) according to the fabrication method of metal frameworks used: HM (via hard milling), SM (via soft metal milling), L25 (via direct metal laser melting [DMLM] with a 25 ㎛ layer thickness), and L50 (via direct DMLM with a 50 ㎛ layer thickness). After the metal frameworks were fabricated and cemented, five vertical marginal discrepancy measurements were recorded in each site (i.e., buccal, facing the pontic, lingual, and facing away from the pontic) of both abutment teeth under a stereomicroscope (×40). Data were statistically analyzed at a significance level of 0.05. RESULTS. No statistically significant differences (P>.05) were found among the four axial sites of metal frameworks fabricated by sintering-based CAD/CAM techniques. The HM and L25 groups showed significantly (P<.001) lower marginal discrepancy values than the SM and L50 groups. CONCLUSION. Marginal discrepancy in the sites facing the pontic was not influenced by the type of sintering procedure. All fabrication methods exhibited clinically acceptable results in terms of marginal discrepancies.