• Title/Summary/Keyword: Soft Contact lenses

Search Result 80, Processing Time 0.019 seconds

A Survey about Wearing Soft Contact Lenses for Astigmatism Correction of The Local College Students, Gyeongsangnam-Do, Korea (경남지역 대학생들의 난시 교정용 소프트 콘택트렌즈의 착용에 관한 설문조사)

  • Kim, Bong-Hwan;Han, Seon-Hee;Kim, Dae-Hyeon;Byeon, Sang-Hyeon;Chae, Jeong-Im;Kim, Jae-Seok;Hwang, Yun-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.3
    • /
    • pp.378-389
    • /
    • 2015
  • Purpose. The actual status of wearing toric soft contact lenses was investigated to learn why it is not used although it is required. Materials and Methods. This study has studied 64 contact lens wearing the local college students, Gyeongsangnam-do who are 20.17(${\pm}0.70$)years old, by measuring their refractive power and over-refractive power with auto refractometer(HRK-8000A, Huvitz, Korea). In addition to that, a survey was done to figure out why they do not wear toric soft contact lenses, the purpose of using toric soft contact lenses, whether they have astigmatism or any knowledge about it, the kinds of contact lens, whether they are willing to buy corrective lenses, and how they are satisfied after purchasing them. Results. 17 students (21.9%) said they experienced light-spread; 9 students (14.1%)said that they have dizziness when they wear contact lens all day long. In the survey to see whether they had astigmatism or not, 37 students (57.8%) said they had it. For the reason they do not wear toric soft contact lenses, 33 students (51.6%) said that "they were prescribed regardless of astigmatism in the optometrist." To the question asking if they are willing to buy toric soft contact lenses according to the existence of astigmatism, 51 students (79.6%) answered they are. 31 students (48.4%) said they heard a description about astigmatism at the time of purchase for contact lens. Conclusion. As the ways for any people who need to correct astigmatism to wear corrective lens, enough education about astigmatism and consistent follow-up management are needed, where the role of optometrist is considered important.

Evaluation of Oxygen Permeability of Soft Contact Lenses Based on Thickness (두께 기준에 따른 소프트 콘택트렌즈의 산소투과성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2157-2163
    • /
    • 2009
  • The oxygen permeability of a soft contact lens is an important parameter for determining corneal health when considering the physiological response of the eye. The aim of this study is to evaluate the oxygen permeability of soft contact lenses based on thickness, using the polarographic method. The thickness of lens was measured using contact and non-contact method. To assess accuracy and reliability, the Bland-Altman plot was used. The reliability was high for the oxygen permeability based on center thickness measured by contact method, whereas the accuracy was high for the oxygen permeability based on center thickness measured by non-contact method. These results indicate that the permeability characteristics were variable according to the measurement and criteria of thickness of soft contact lenses and the measurement of soft contact lenses by non-contact method was more reasonable. Thus, contact lens practitioners should consider some basic differences between methodologies when interpreting or quoting oxygen performance data.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

The study on the understanding and contentment of training of using soft contact lenses (연성 콘택트렌즈 관리교육의 이해도·만족도 조사)

  • Shin, Jang Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.13-18
    • /
    • 2002
  • This study conducts the soft contact lenses user's understanding and contentment of training while at the place of purchase. It is based on a questionnaire to the residents in and outside the Masan area, aged between ten to thirty, who have worn soft contact lenses. It examines the training of using contact lenses and lens-care products, the period of wearing lenses, exchanging lenses, sterilizing lenses, side effects of using lenses or the periodic examination, and the understanding and contentment of the users during the training. The results of the research are as below : First, the understanding of training of using lenses, using lens-care products, the period of wearing lenses, exchanging lenses was high, but it was low for the training of sterilizing lenses, side effects of wearing lenses or the periodic examination. Second, the contentment of training of using lenses, lens-care products, the period of wearing lenses, exchanging lenses was high, but low for the training of sterilizing lenses, side effects of wearing lenses or the periodic examination. Therefore, the trainer of the contact lenses must easily and sincerely explain sterilizing lenses, the side effects of using lenses and the periodic examination, cheek with the users, and provide guidelines so as to improve the understanding and the contentment of training of using contact lenses.

  • PDF

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

The Evaluation of Property of Colored Contact Lenses (칼라콘택트렌즈의 물성적 특성 평가)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.119-126
    • /
    • 2005
  • The purpose of this study was analyzed to compare on the physical characters of two companies of color contact lenses. Artificial tear solution was used for measuring the rate of protein deposits and wettability. The surface roughness of lenses was measured by SEM(scanning electron microscope, Japan) and AFM(atomic force microscope, MultimodeTM, USA). As a results, The color contact lenses was not different from general soft contact lenses in a respect of other properties. However, the colored contact lenses showed a severe crack on the surface under SEM observation. There was no irregularity on the surface of the colored contact lenses in AFM photograph. The dyes were deposited in inside of lenses by microscope observation.

  • PDF

The Status of Soft Contact Lens Wear in College Students in Korea (한국 대학생들의 소프트 콘택트렌즈 착용에 대한 실태)

  • Kim, Douk-Hoon;Kim, Joung-Suk;Mun, Joung-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.233-239
    • /
    • 2004
  • This study investigated the status of soft contact lens wear in college students. The results were as follows: 1. The most prevalent age of initial contact lens wear was 19 years or 20 years, with an age distribution in females from as early as 10 years to 20 years. 2. For almost all subjects, the test clinic for the contact lens wear assessment and purchase of the contact lenses was an optical shop. 3. The main advantage for most male subjects was use for sports, whereas most female subjects used contact lenses for cosmetic reasons. 4. The most common side-effects experienced due to contact lens wear were red eye, foreign body sensation, and eye pain. 5. The most frequently reported eye disease caused by contact lens wear was conjunctivitis, with only few subjects experiencing keratitis. 6. Following treatment for the side effects of contact lens wear, most subjects hoped to re-use the previous contact lenses, some subjects wanted to change to new contact lenses, and others subjects refused further contact lens wear.

  • PDF

Fitting of Soft Contact Lenses (소프트 콘택트 렌즈의 피팅)

  • Lee, Eun-Hee;Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.173-180
    • /
    • 2000
  • To determine the effect of base curve and diameter of soft contact lenses on the fitting under the various corneal curvature, the model eyes which was made of either stainless steel or ordinary wood, were used as the substitutes for human eyes. The evaluations of fit of the soft contact lenses on both wood model eyes and human eyes were found to be very similar to each other. All the contact lenses except very thin ones became flat after fit on the stainless steel model eyes because the model eye could not preserve enough moisture to hold the edge of contact lenses on the steel ball's surface. The relationships between the base curves of contact lenses and radii of cornea for the optimum (normal) fit were measured as follows : corneal curvature (C.C)<7.6 mm : base curve(B.C) 8.4 mm, C.C 7.6~7.8 mm : B.C 8.4~8.5 mm. C.C 7.8~8.1 mm : B.C 8.6 mm. It is concluded that larger base curve is required for the eyes which have abnormal bulge on its cornea. It is found that very thin soft contact lenses can be easily twisted or folded regardless of moisture content when they were fit on the relatively dry eyes(corneas).

  • PDF

Relationship between the Deposition of Tear Constituents on Soft Contact Lenses according to Material and Pigmentation and Adherence of Staphylococcus aureus (소프트콘택트렌즈 재질과 착색에 따른 눈물성분 침착과 포도상구균 흡착의 상관관계)

  • Park, So Hyun;Park, Ill-suk;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.109-117
    • /
    • 2016
  • Purpose: The study was aimed to figure out the effect of materials and pigmentation of soft contact lens on the adherence of Staphylococcus aureus upon soft contact lenses deposited with tear components. Methods: The number of adherent S. aureus on clear and circle soft contact lenses made of etafilcon A, hilafilcon B, nelfilcon A was measured before and after incubation in artificial tear. Furthermore, the denaturalization level of tear protein with time after incubation in artificial tear was estimated by electrophoresis. Results: The adherence of S. aureus was significantly different according to the lens materials. The pattern of bacterial adherence on clear and circle contact lenses was different. That is, the adherent amount of S. aureus was somewhat larger on circle lens made of etafilcon A however, amount on circle lenses made of hilafilcon B and nelfilcon A was 89.3% and 71.3% of the number on clear lenses. When the tear protein was deposited on contact lenses, the number of adherent bacteria decreased and its degree was varied according to the lens material. The degree of decrease was the biggest in clear soft lens made of etafilcon A. Anti-bacterial effect of tear protein decreased with time after deposition of tear protein on soft contact lens and the amount of lysozyme also decreased. The reduction of anti-bacterial effect and quantity of lysozyme was different according to contact lens materials and pigmentation. Conclusions: It was revealed that the adherence of S. aureus depends on contact lens materials and pigmentation, and the specification of lens material affects more on adherence of S.aureus than pigmentation. It was further figured out the denaturalization level of anti-bacterial protein on soft contact lens varies according to lens materials and pigmentation, which produces an effect on the quantity of bacterial adherence.

Correlations between Axial Rotation of Toric Soft Contact Lenses and Corneal Eccentricity according to the Wearing Time and Gaze Directions (착용시간 및 응시방향에 따른 토릭소프트콘택트렌즈의 축 회전과 각막이심률과의 상관관계)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of corneal eccentricity on the axial rotation when wearing toric soft contact lenses were worn for certain time and changing the gaze directions. Methods: Toric soft contact lenses with double thin zone design applied on 85 of with-the-rule astigmatic eyes. Then, rotational direction and amount of contact lenses were measured after 15 minutes and 6 hours of lens wear. The difference was further compared and analyzed according to corneal eccentricity. Results: The rotation of toric lens showed a tendency to rotate to temporal direction in all gaze directions except temporal-upper direction in all groups of corneal eccentricity. The amount of lens rotation in the frontal gaze direction exhibited a negative correlation since the amount was decreased with increasing corneal eccentricity after both 15 minutes and 6 hours of lens wearing. In many cases, the cornea with small eccentricity also showed the lens rotation larger than $10^{\circ}$. The difference in rotational amount after 15 minutes of toric lens wear was small according to the corneal eccentricity however, the change of rotational amount of contact lens according to corneal eccentricity was shown after 6 hours of lens wear. Conclusions: The present study revealed that the amount of axial rotation was largely varied according to the wearer's corneal eccentricity when wearing toric lens and the rotational amount after certain time of lens was also affected by corneal eccentricity. Thus, it is suggested that the selection of toric soft contact lenses based on corneal eccentricity is necessary.