• 제목/요약/키워드: Snow loads

검색결과 44건 처리시간 0.021초

Rehabilitation of a distressed steel roof truss - A study

  • Dar, M.A.;Subramanian, N.;Dar, A.R.;Raju, J.
    • Structural Engineering and Mechanics
    • /
    • 제62권5호
    • /
    • pp.567-576
    • /
    • 2017
  • Structural failures are undesirable events that devastate the construction industry resulting in loss of life, injury, huge property loss, and also affect the economy of the region. Roof truss failures occur mainly due to excessive loading, improper fabrication, deterioration, inadequate repair, etc. Although very rare, a roof truss may even fail due to inappropriate location of supports. One such case was reported from the recent failure of a steel roof truss used in an indoor stadium at Kargil in India. Kargil region, being mountainous in nature, receives heavy snowfall and hence the steel roof trusses are designed for heavy snow loads. Due to inappropriate support location, the indoor stadium's steel roof truss had failed under heavy snow load for which it was designed and became an interesting structural engineering problem. The failure observed was primarily in terms of yielding of the bottom chord under the supports, leading to partial collapse of the roof truss. This paper summarizes the results of laboratory tests and analytical studies that focused on the validation of the proposed remedial measure for rehabilitating this distressed steel roof truss. The study presents the evaluation of (i) significant reduction in strength and stiffness of the distressed truss resulting in its failure, (ii) desired recovery in both strength and stiffness of the rectified truss contributed by the proposed remedial measure. Three types of models i.e., ideal truss model, as build truss model and rectified truss model were fabricated and tested under monotonic loading. The structural configuration and support condition varied in all the three models to represent the ideal truss, distressed truss and the rectified truss. To verify the accuracy of the experimental results, an analytical study was carried out and the results of this analytical study are compared with the experimental ones.

와이드 스팬형 및 2-Bay 벤로형 유리온실 구조부재의 최적단면 설계 (Design of Optimum Section for Structural Members of Wide Span-Type and 2-Bay Venlo-Type Glass Green Houses)

  • 박종섭;김용희;서광규;김영식
    • 생물환경조절학회지
    • /
    • 제20권1호
    • /
    • pp.50-57
    • /
    • 2011
  • 본 연구는 한국형 온실 표준설계도 및 Greenhouse Structure Design Manual(1999)에 의거하여 최대설계 하중을 받는 와이드스팬형파 2-bay벤로형 온실시스템에 대하여 해석적 연구를 진행하였다. 상부구조물을 라멘형식으로 단순화한 구조형식에 BOX형 및 I형 단면을 적용하여 다음과 같은 결과를 얻을 수 있었다. 한국형 유리용실 표준도를 활용하여 라멘형식의 단순화된 와이드스팬형 및 2-bay 온실구조시스템의 안전성 평가결과 기존의 트러스 등의 보강재가 적용되지 않을 경우 안전성확보에 문제가 발생할 수 있음을 확인할 수 있었다. 또한 유리온실 표준도를 라멘형식으로 단순화하고 Greenhouse Structure Design Manual (1999)이 제안하고 있는 최대하중에 대해 경량I형 단면 부재를 적용할 경우 안전성을 확보할 수 있다. 본 연구에서는 경제적인 경량 I형 단면 3가지의 적용성을 평가하였으며, 검토조건에 부합하는 최소 기둥단면($H200{\times}175{\times}3.2{\times}6$)을 제시하고 있다. 와이드스팬형 및 벤로형 온실형식의 안전성평가에서 발생되는 처짐은 매우 작은 값을 나타내고 있으며, 발생되는 응력이 보다 민감하게 발생하는 것을 알 수 있다. 따라서 검토된 온실표준단변형식이 전체적인 구조변형에는 안전하나 응력발생이 일부부재에서 취약함으로 변단면 등을 활용하여 경제성을 확보할 수 있다. 온실의 채광량, 시공성 및 안전성을 고려하여 벤로형 구조시스템이 널리 사용되고 있으며, 지붕높이의 변화를 통하여 보다 경제적인 형식이 개발가능하며, 3-bay 벤로형의 추가적인 연구가 필요하다.

목재 조립보 헤더의 휨 성능 분석 (Analysis of Bending Performance of Built-up Beam Headers)

  • 장상식;김윤희;박영란
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권6호
    • /
    • pp.118-125
    • /
    • 2007
  • 경골목조건축공법에서 개구부의 헤더로 많이 사용되는 조립보에 대한 설계자료를 구하기 위하여 $2{\times}6$ ($38{\times}140 mm$), $2{\times}8$ ($38{\times}184 mm$), $2{\times}10$ ($38{\times}235 mm$) 및 $2{\times}12$ ($38{\times}286 mm$) 부재를 3개 겹쳐서 휨 시험편을 제작하였다. 이들에 대한 휨 시험을 통하여 조립보에 대한 허용응력을 구하고 허용응력에 근거하여 여러 가지 하중 조건에 대한 경간표를 작성하였다. 조립보에 대한 휨 시험 결과로부터 10 mm의 처짐이 발생할 때의 휨응력을 조립보 헤더의 휨강도로 산정하였다. 조립보에 대한 경간표는 외벽에서 헤더가 사용되는 위치에 따른 5가지 하중조건과 내벽에서 헤더가 사용되는 위치에 따른 2가지 하중조건을 고려하여 작성할 수 있는 것으로 생각된다. 총 7가지 하중 조건에 있어서 외벽에 사용되는 헤더에 대한 5가지 하중조건에서는 고정하중, 활화중 및 적설하중이 포함되었으며 내벽에 사용되는 헤더에 대한 2가지 하중조건에서는 고정하중과 활하중이 포함되었다.

성주지역 참외 재배용 온실구조 현황 및 모델 개발 (Current Status and Development of Greenhouse Models for Oriental Melon Cultivation in Seongju Region)

  • 이종원;백철현;이현우;정성원
    • 생물환경조절학회지
    • /
    • 제23권2호
    • /
    • pp.95-108
    • /
    • 2014
  • 본 연구는 성주지역에 적합한 참외재배용 내재해형 온실을 개발하기 위하여 참외 재배온실의 구조현황 조사, 최근 기상자료가 반영된 설계하중 산정, 온실모델 설정 및 구조안전성 분석을 수행하였으며 결과를 요약하면 다음과 같다. 성주지역 참외온실의 구조적 특성을 파악하기 위하여 현장 조사한 결과, 온실의 지붕형상은 아치형이 가장 많았으며, 최근에 시공한 온실일수록 복숭아형이 많았으며 폭이 넓어지고 동고도 높아지는 추세였다. 그리고 성주지역에 가장 인접한 구미기상대의 기상자료를 이용하여 재현기간에 따른 설계풍속 및 설계적설심을 산정할 수 있는 계산식을 유도하였으며, 내재해형 온실규격을 만족하는 재현기간 30년의 적설심은 23.7cm, 풍속은 $33.8m{\cdot}s^1$로 계산되었다. 이러한 성주지역의 내재해형 설계기준을 만족하는 참외재배용 단동온실 4종, 2연동온실 및 연결온실을 각각 1종씩 총 6종의 모델을 개발하였다.

FRP 패널로 보강한 강골조의 가이드 시스템에 따른 성능평가 (Performance Evaluation of Steel Frame with FRP Composite Panel according to Guide System)

  • 임정희;권민호;서현수;김진섭
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.46-51
    • /
    • 2015
  • Since it is impossible to predict earthquakes, they involve more casualties and property damage compared to meteorological disasters such as heavy snow and heat waves, which can be predicted through weather forecasts. This has highlighted the need for seismic design and reinforcement. Recently, the use of composite materials as reinforcement has surged because steel plate reinforcement and section enlargement are likely to result in increased weight and physical damage to structures. This study evaluates the seismic performance of panels created from composite materials, and their guide systems. The specimens were miniature versions of actual steel structures, and displacement loads were applied in the transverse direction. Seismic performance was found to improve when structures were reinforced with seismic panels.

Micro-cracks에 의한 PV 모듈의 전기적 특성 분석 (The analysis of electrical characteristics with Micro-crack in PV module)

  • 송영훈;지양근;;강기환;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF

막장력 측정을 통한 막구조물의 장력 유지관리 시스템 검토 (Review of Membrane Tension Maintenance System for Membrane Structures through Membrane Tension Measurement)

  • 진상욱;손수덕;이승재
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.39-45
    • /
    • 2016
  • Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.

CFD 해석을 이용한 가변 차양 장치의 풍압력 분석 (Wind Pressure Analysis of Movable Shading Using CFD)

  • 김기철;이준호;백용규
    • 한국공간구조학회논문집
    • /
    • 제19권2호
    • /
    • pp.83-90
    • /
    • 2019
  • Most of the variable shading devices are installed outdoors, so they are greatly affected by structural safety due to external climate change, wind, rain, and snow. Especially, due to strong wind such as typhoons, safety problems may occur due to the dropout of the device. Therefore, it is necessary to secure the structural safety against the wind. Therefore, it is necessary to analyze the structural behavior of the windshield to evaluate the structural safety of the variable sunshade device. In this study, we analyze the wind pressure applied to the shading material according to the change of the length of the variable shading device, and apply it to the calculation of the wind load for the structural design of the variable shading device. The CFD (Computational Fluid Dynamic) analysis of the structure of the sample was used to analyze wind pressure magnitude and distribution. In order to estimate the wind pressure, the maximum wind loads of the static and negative pressures acting on the structure were analyzed from numerical simulation results.

토마토 재배용 연동 플라스틱 온실 개발 (Development of Multi-span Plastic Greenhouse for Tomato Cultivation)

  • 유인호;이응호;조명환;류희룡;김영철
    • 생물환경조절학회지
    • /
    • 제21권4호
    • /
    • pp.428-436
    • /
    • 2012
  • 본 연구에서는 토마토 재배에 적합한 규격을 가지면서 기상재해에 안전한 토마토 재배용 연동 비닐하우스를 설계하였다. 토마토 하우스의 규격은 폭 7m, 측고 4.5m, 동고 6.5m이다. 1995년에 농촌진흥청에서 개발한 1-2W형 하우스와 비교해서 폭은 같지만 측고는 1.8m, 동고는 2m 더 높다. 중방은 작물하중과 장치하중을 견딜 수 있도록 트러스 구조로 설계하였다. 토마토 하우스는 높으면서도 내재해 설계 기준(MIFFAF, 2010)에 맞게 만들어졌다. 즉, 최고 설계 기준인 풍속 $40m{\cdot}s^{-1}$, 적설 40cm 이상에 안전하도록 구조안전성 분석을 통해 하우스 기둥, 서까래 등의 부재 규격과 설치 간격을 설정하였다. 1-2W형 하우스와 달리 토마토 하우스에는 랙-피니언 타입의 천창을 용마루 부분에 설치하여 외부 공기 유입과 자연 환기를 극대화할 수 있도록 하였다. 하우스 높이가 증가하면 난방비는 증가하므로 토마토 하우스에는 보온력이 우수한 다겹 보온커튼을 설치하여 하우스 바깥으로 빠져나가는 열을 최소화하였다.

고랭지 밭 유역의 융설에 의한 비점오염원 특성과 오염부하산정 (Characteristics of NPS Pollution and Calculation of Pollutant Loads in a Song-cheon watershed during the Snow Melting Season)

  • 박병준;최용훈;신민환;서지연;최중대
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.269-273
    • /
    • 2011
  • 본 연구는 도암댐 상류 고랭지 농업지역의 이른 봄철 융설에 의해 발생되는 비점오염 물질의 배출 특성을 규명하고자 수행하였다. 연구는 2010년 2월 중순부터 4월 말까지 수행하였다. 연구지역에서는 2009년 11월 2일부터 2010년 4월 29일까지 눈이 내렸으며, 일 최대 적설량은 2월 11일에 기록된 59.3 cm이고, 총 적설량은 372.1 cm로 나타났다. 연구결과 융설에 의해 발생되는 단위 면적당 유량은 $77.05\;m^3$/ha/day로서 겨울철 평시 유량 $26.99\;m^3$/ha/day에 비해 두배 가까이 증가하였다. 유량의 변화는 기온의 영향을 많이 받는 것으로 나타났으며, 유량의 변화는 탁도와 SS 그리고 $COD_{Mn}$의 농도 변화에 영향을 주는 것으로 조사되었다. 오염물질 항목 중 SS와 COD의 유량가중평균농도는 각각 986.0 mg/L와 16.3 mg/L로서 겨울철 평시 농도보다 크게 증가하였는데, 이는 융설시 발생한 유출수에 의해 미세한 토양입자의 유실과 함께 오염물질도 배출된 결과로 판단된다. 그러나 T-N과 T-P의 농도는 큰 변화가 없는 것으로 조사되었다. 본 연구결과에 기초할 때, 담수호 상류에 위치한 고랭지 지역에서는 겨울철 적설량이 많고 융설에 의한 수질오염 문제가 하는 것으로 판단된다. 따라서 해빙기 융설로 인해 발생되는 비점오염 물질의 정량화에 대한 연구가 체계적이고 지속적으로 수행될 필요가 있다. 특히 우리나라의 겨울철 적설량과 기온은 연도별로 많은 편차가 있고, 연구결과 다량의 오염물질이 배출되기 때문에 융설에 대한 연구는 반드시 수행되어야 할 것으로 판단된다.

  • PDF