• Title/Summary/Keyword: Smooth index

Search Result 108, Processing Time 0.022 seconds

Dose comparison according to Smooth Thickness application of Range compensator during proton therapy for brain tumor patient (뇌종양 환자의 양성자 치료 시 Range Compensator의 Smooth Thickness 적용에 따른 선량비교)

  • Kim, Tae Woan;Kim, Dae Woong;Kim, Jae Weon;Jeong, Kyeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.139-148
    • /
    • 2016
  • Purpose : Range Compensator used for proton therapy compensates the proton beam dose which delivers to the normal tissues according to the Target's Distal Margin dose. We are going to check the improvement of dose on the target part by comparing the dose of PTV and OAR according to applying in different method of Smooth Thickness of Range Compensator which is used in brain tumor therapy. Materials and Methods : For 10 brain tumor patients taking proton therapy in National Cancer Center, Apply Smooth Thickness applied in Range Compensator in order from one to five by using Compensator Editor of Eclipse Proton Planning System(Version 10.0, Varian, USA). The therapy plan algorithm used Proton Convolution Superposition(version 8.1.20 or 10.0.28), and we compared Dmax, Dmin, Homogeneity Index, Conformity Index and OAR dose around tumor by applying Smooth Thickness in phase. Results : When Smooth Thickness was applied from one to five, the Dmax of PTV was decreased max 4.3%, minimum at 0.8 and average of 1.81%. Dmin increased max 1.8%, min 1.8% and average. Difference between max dose and minimum dose decreased at max 5.9% min 1.4% and average 2.6%. Homogeneity Index decreased average of 0.018 and Conformity Index didn't had a meaningful change. OAR dose decreased in Brain Stem at max 1.6%, min 0.1% and average 0.6% and in Optic Chiasm max 1.3%, min 0.3%, and average 0.5%. However, patient C and patient E had an increase each 0.3% and 0.6%. Additionally, in Rt. Optic Nerve, there was a decrease at max 1.5%, min 0.3%, and average 0.8%, however, patient B had 0.1% increase. In Lt. Optic Nerve, there was a decrease at max 1.8%, min 0.3%, and average 0.7%, however, patient H had 0.4 increase. Conclusion : As Smooth Thickness of Range Compensator which is used as the proton treatment for brain tumor patients is applied in stages, the resolution of Compensator increased and as a result the most optimized amount of proton beam dose can be delivered. This is considered to be able to irradiate the equal amount at PTV and reduce the unnecessary dose applied at OAR to reduce the side effects.

  • PDF

An Upper Bound on the Index of the Smoothest Density With Given Moments

  • Changkon Hong
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.2
    • /
    • pp.283-290
    • /
    • 1996
  • For finite discrete distributions with prescribed moments, there is a well-known upper bound on the index of the support. In this paper, we are interested in the smoothest density with prescribed moments among the class of smooth functions. We define an index of continuous distribution through the support and derive an upper bound on the index of the smoothest density. Some examples are given, some of which achieve the upper bound.

  • PDF

Circumferential Alignment of Vascular Smooth Muscle Cells in a Cylindrical Microchannel

  • Choi, Jong Seob;Piao, Yunxian;Kim, Kyung Hoon;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.274.1-274.1
    • /
    • 2013
  • We report the circumferential alignment of human aortic smooth muscle cells (HASMCs) in an orthogonally micropatterned circular microfluidic channel to form an in vivo-like smooth muscle cell layer. To realize a biomimetic smooth muscle cell layer which is aligned perpendicular to the axis of blood vessel, we first fabricated a half-circular polydimethylsiloxane (PDMS) microchannel by soft lithography using a convex PDMS mold. The orthogonally micro wrinkle patterns were generated inside the half-circular microchannel by stretching-releasing operation under UV irradiation. Upon UV treatment with uniaxial 40 % stretch of a PDMS substrate and releasing process, the microwrinkle patterns perpendicular to the axial direction of the circular microchannel were generated, which could guide the circumferential alignment of HASMCs successfully during cultivation. The analysis of orientation angle, shape index, and contractile protein marker expression indicates that the cultured HASMCs revealed the in vivo-like cell phenotype. Finally, we produced circular microchannels by bonding two half-circular microchannels, and cultured the HASMCs circumferentially with high alignment and viability for 5 days. These results are the first demonstration for constructing an in vivo-like 3D smooth muscle cell layer in the circular microfluidic channel which can provide novel bioassay platforms for in-depth study of HASMC biology and vascular function.

  • PDF

Evaluating the effective spectral seismic amplification factor on a probabilistic basis

  • Makarios, Triantafyllos K.
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.121-129
    • /
    • 2012
  • All contemporary seismic Codes have adopted smooth design acceleration response spectra, which have derived by statistical analysis of many elastic response spectra of natural accelerograms. The above smooth design spectra are characterized by two main branches, an horizontal branch that is 2.5 times higher than the peak ground acceleration, and a declining parabolic branch. According to Eurocode EN/1998, the period range of the horizontal, flat branch is extended from 0.1 s, for rock soils, up to 0.8 s for softer ones. However, from many natural recorded accelerograms of important earthquakes, the real spectral amplification factor appears to be much higher than 2.5 and this means that the spectrum leads to an unsafe seismic design of the structures. This point is an issue open to question and it is the object of the present study. In the present paper, the spectral amplification factor of the smooth design acceleration spectra is re-calculated on the grounds of a known "reliability index" for a desired probability of exceedance. As a pilot scheme, the seismic area of Greece is chosen, as it is the most seismically hazardous area in Europe. The accelerograms of the 82 most important earthquakes, which have occurred in Greece during the last 38 years, are used. The soil categories are taken into account according to EN/1998. The results that have been concluded from these data are compared with the results obtained from other strong earthquakes reported in the World literature.

Sharing a Large Secret Image Using Meaningful Shadows Based on VQ and Inpainting

  • Wang, Zhi-Hui;Chen, Kuo-Nan;Chang, Chin-Chen;Qin, Chuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.12
    • /
    • pp.5170-5188
    • /
    • 2015
  • This paper proposes a novel progressive secret image-hiding scheme based on the inpainting technique, the vector quantization technique (VQ) and the exploiting modification direction (EMD) technique. The proposed scheme first divides the secret image into non-overlapping blocks and categorizes the blocks into two groups: complex and smooth. The blocks in the complex group are compressed by VQ with PCA sorted codebook to obtain the VQ index table. Instead of embedding the original secret image, the proposed method progressively embeds the VQ index table into the cover images by using the EMD technique. After the receiver recovers the complex parts of the secret image by decoding the VQ index table from the shadow images, the smooth parts can be reconstructed by using the inpainting technique based on the content of the complex parts. The experimental results demonstrate that the proposed scheme not only has the advantage of progressive data hiding, which involves more shadow images joining to recover the secret image so as to produce a higher quality steganography image, but also can achieve high hiding capacity with acceptable recovered image quality.

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

Cutaneous smooth muscle tumors in 3 dogs

  • Jung, Ji-Youl;Kang, Sang-Chul;Park, Dae-Sik;Lee, Eun-Sung;Bae, Jong-Hee;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.1
    • /
    • pp.63-66
    • /
    • 2009
  • Cutaneous leiomyomas (leiomyosarcomas) are smooth muscle tumors that occur single or as multiple lesions. They usually arise from the arrector pili muscles (piloleiomyomas) and less commonly from the muscle of veins (angioleiomyomas). This report describes histologic and immunohistochemical features of one cutaneous piloleiomyoma and two angioleiomyosarcomas. Three 7-12-year-old female dogs were presented with single or double cutaneous nodules. Histologically, the neoplastic masses were composed of densely or loosely arranged interlacing bundles. The neoplastic cells were ovoid to elongate, and had eosinophilic cytoplasms and perinuclear cytoplasmic vacuolation. Nuclei were central to eccentric, cigar shaped, oval to elongate. In two cases, high mitotic index in high power field, multifocal necrosis and local invasion were also noted. Masson's trichrome and van Gieson staining revealed muscle origin tumors in these cases. Immunohistochemically, the tumor cells were strongly positive for smooth muscle actin. In our best knowledge, this is the first report of cutaneous smooth muscle tumors in dogs in Korea.

A Comparison of Smooth and Microtextured Breast Implants in Breast Augmentation: A Retrospective Study

  • Joo Hyuck Lee;Jae Hyuk Jang;Kyung Hee Min
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.160-165
    • /
    • 2023
  • Background The number of cosmetic and reconstructive surgeries that use breast implants is increasing in Korea. Recently, it has been reported that breast implant-associated anaplastic large-cell lymphoma is related to textured breast implants, and interest in classification according to the texture of breast implants is increasing. However, there is currently no clear and unified classification. In particular, the definition of "microtextured" is highly varied. In this study, we retrospectively investigated and analyzed the clinical outcomes of smooth and microtextured breast implants. Methods A retrospective chart review of all patients who underwent breast augmentation surgery with smooth and microtextured silicone gel implants between January 2016 and July 2020 was performed. We retrospectively analyzed implant manufacturer, age, body mass index (BMI), smoking status, incision location, implant size, follow-up period, complications, and reoperation rate. Results A total of 266 patients underwent breast augmentation surgery, of which 181 used smooth silicone gel implants and 85 used microtextured silicone gel implants. Age, BMI, smoking status, implant size, and follow-up period were not significantly different between the two groups. Similarly, complications and reoperation rates were not significantly different between the two groups. Conclusion It is important to provide information regarding the clinical risks and benefits of breast implants to surgeons and patients through a clear and unified classification according to the texture of the breast implant.

Nanocomposite Cover-layer for NFR Media (Nanocomposite 이용한 NFR Media 커버층 특성연구)

  • Kim, Jin-Hong;Lee, Jun-Seok;Seo, Jeong-Kyo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 2007
  • [ $TiO_2$ ] nanoparticles are added into UV curable resin to increase the refractive index of the cover-layer which is laminated on the media for cover-layer incident NFR. High refractive index is required for the cover-layer operating for the solid immersion lens optics with high effective numerical aperture. The eyepattern could be achieved from the cover-layer coated 20 GB ROM disc in which the refractive index of the cover-layer was 1.75, but the gap servo was unstable due to the rough surface of the cover-layer. Even though the light loss due to the nanoparticles is not serious, the rough microstructure is developed by adding the nanoparticles in the organic binder material. To achieve smooth surface for the stable gap servo, some special techniques should be added, for example the solubility of the nanoparticles should be enhanced by the optimization of the surface of the nanoparticles.

  • PDF

Observations of a endometrial stromal sarcoma in the rat uterus wall (Rat의 자궁벽에 발생된 stromal sarcoma의 관찰)

  • Kwak, Soo-dong;Kim, Chong-sup
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.435-439
    • /
    • 1994
  • The present observation was focussed mainly on the histopathological and immunohistochemical finding of the tumor developing from the outside of rat uterus wall. In gross finding, this tumor were a oval form mass and 0.75cm and 1cm in greatest demension. The sectioned surface showed uniform, solid, gray-white. In histopathological finding, the tumor showed the form of lymphoid nodule-like structure and was composed of the cells with karryorrhexis, karyolysis and necrosis in the central zone, mature cells in the paracentral zone, and concentric layers of compressed, flattened and atrophied smooth muscle fibers by the proliferating of the cells closely resembling endometrial stromal ells in the peripheral zone and a few smaller nodule-like structure in certain areas of the peripheral zone. In immunohistochemical observations, the proliferating cells presents only among the concentric layers of the smooth muscle fibers in the peripheral zone. Labeling index of proliferating cells in the peripheral zone was $4.34{\pm}1.28%$. These tumor cells did not metastasized in another orgns and labeling index was low, So it was concluded that this tumor was benign stomal sarcoma.

  • PDF