• Title/Summary/Keyword: Smooth Tubes

Search Result 122, Processing Time 0.026 seconds

Convective Boiling of R-l34a in a Bundle of Smooth Tubes

  • Kim, Jung-Oh;Cho, Jin-Pyo;Kim, Nae-Hyun;Choi, Kuk-Kwang
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.79-87
    • /
    • 2002
  • In this study, flow boiling experiments were performed using R-134a on a plain tube bundle. Tests were conducted for the following range of variables; quality from 0.1 to 0.9, mass flux from 8kg/$m^2$s to 26 kg/$m^2$s and heat flux from 10kW/$m^2$ to 40kW/$m^2$. The heat transfer coefficients were strongly dependent on the heat flux. However, they were almost independent on the mass flux or quality. The data are compared with the modified Chen model, which predicted satisfactorily ($\pm$30%) the data. The Original Chen model, however, did not adequately predict the effect of quality. The reason may be attributed to the flow pattern of the present test, where the bubbly flow prevailed for the entire test range. The heat transfer coefficients of the tube bundle were 6~40% higher than those of the single tube pool boiling.

Occurrence of severe soybean-sprout rot caused by Pythium deliense in the recirculated production system

  • Yun, Sung-Chul
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.92.2-93
    • /
    • 2003
  • Severe soybean-sprout rot was found at the mass productive factory in 2000 and 2001 and it caused 10-20% loss of the production. Pythium sp. was isolated almost 90% by potato dextrose agar from rotted root and hypocotylsof the sprouts. And the pathogencity tests using test tubes with 2% water agar and small containers (30 ${\times}$ 30 ${\times}$ 50 cm, WxLxH) cultivation were shown a similar rot on roots and hypocotyls. The fungal mycelium grew rapidly on the water agar and it prevented the seed germination. Density of the Pythium sp. in the recycled water system at the factory was periodically measured using a selective medium, corn meal agar with Pimaricin 10 mg, Rifampicin 10 mg, Ampicillin 100 mg per 1 liter in order to check the contamination of recycled water. After fitering step using 5 and 1 ml in the recycled system was applied and it was effectively controlled Pythium rot. The daily yield of sprout was stable and the occurrenceof Pythium in the recycled water was much less after filtering. The fungal isolates were identified as Pythium deliense Meurs based on various mycological characteristics on corn meal agar and sucrose-asparagine bentgrass leaf culture medium. P. deliens oogonia were spherical, smooth, 19-23 urn in diameter, and their stalk bending toward antheridia. Antheridia were straw hat-shaped, curred club-shaped, therminal or intercalary, monoclinous, occasionally diclinous, 12∼15 ${\times}$ 8∼11 um, 1(∼2) per oogonium.

  • PDF

Vibration analysis of sandwich sectorial plates considering FG wavy CNT-reinforced face sheets

  • Tahouneh, Vahid
    • Steel and Composite Structures
    • /
    • v.28 no.5
    • /
    • pp.541-557
    • /
    • 2018
  • This paper presents the influence of carbon nanotubes (CNTs) waviness and aspect ratio on the vibrational behavior of functionally graded nanocomposite sandwich annular sector plates resting on two-parameter elastic foundations. The carbon nanotube-reinforced (CNTR) sandwich plate has smooth variation of CNT fraction along the thickness direction. The distributions of CNTs are considered functionally graded (FG) or uniform along the thickness and their mechanical properties are estimated by an extended rule of mixture. In this study, the classical theory concerning the mechanical efficiency of a matrix embedding finite length fibers has been modified by introducing the tube-to-tube random contact, which explicitly accounts for the progressive reduction of the tubes' effective aspect ratio as the filler content increases. Effects of CNT distribution, volume fraction, aspect ratio and waviness, and also effects of Pasternak's elastic foundation coefficients, sandwich plate thickness, face sheets thickness and plate aspect ratio are investigated on the free vibration of the sandwich plates with wavy CNT-reinforced face sheets. The study is carried out based on three-dimensional theory of elasticity and in contrary to two-dimensional theories, such as classical, the first- and the higher-order shear deformation plate theories, this approach does not neglect transverse normal deformations. The sandwich annular sector plate is assumed to be simply supported in the radial edges while any arbitrary boundary conditions are applied to the other two circular edges including simply supported, clamped and free.

Finite element analysis of the fluid-structure interaction in a compliant vessel (유연 혈관에서 유체-고체 상호작용에 대한 유한요소 해석)

  • Shim, Eun-Bo;Ko, Hyung-Jong;Kamm, Roger D.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.591-596
    • /
    • 2000
  • Flow through compliant tubes with linear taper in wall thickness is numerically simulated by finite element analysis. Two models are examined: a planar two-dimensional channel, and an axisymmetric tube. For verification of the numerical method, flow through a compliant stenotic vessel is simulated and compared to existing experimental data. Computational results for an axisymmetric tube show that as cross-sectional area falls with a reduction in downstream pressure, flow rate increases and reaches a maximum when the speed index (mean velocity divided by wave speed) is near unity at the point of minimum cross-section area, indicative of wave speed flow limitation or "choking" (flow speed equals wave speed) in previous one-dimensional studies. For further reductions in downstream pressure, flow rate decreases. Cross-sectional narrowing is significant but localized. When the ratio of downstream-to-upstream wall thickness is ${\le}$ 2 the area throat is located near the downstream end; as wall taper is increased to ${\ge}$ 3 the constriction moves to the upstream end of the tube. In the planar two-dimensional channel, area reduction and flow limitation are also observed when outlet pressure is decreased. In contrast to the axisymmetric case, however, the elastic wall in the two-dimensional channel forms a smooth concave surface with the area throat located near the mid-point of the elastic wall. Though flow rate reaches a maximum and then falls, the flow does not appear to be choked.

  • PDF

In vitro and in vivo Application of PLGA Nanofiber for Artificial Blood Vessel

  • Kim, Mi-Jin;Kim, Ji-Heung;Yi, Gi-Jong;Lim, Sang-Hyun;Hong, You-Sun;Chung, Dong-June
    • Macromolecular Research
    • /
    • v.16 no.4
    • /
    • pp.345-352
    • /
    • 2008
  • Poly(lactic-co-glycolic acid) (PLGA) tubes (5 mm in diameter) were fabricated using an electro spinning method and used as a scaffold for artificial blood vessels through the hybridization of smooth muscle cells (SMCs) and endothelial cells (ECs) differentiated from canine bone marrow under previously reported conditions. The potential clinical applications of these artificial blood vessels were investigated using a canine model. From the results, the tubular-type PLGA scaffolds for artificial blood vessels showed good mechanical strength, and the dual-layered blood vessels showed acceptable hybridization behavior with ECs and SMCs. The artificial blood vessels were implanted and substituted for an artery in an adult dog over a 3-week period. The hybridized blood vessels showed neointimal formation with good patency. However, the control vessel (unhybridized vessel) was occluded during the early stages of implantation. These results suggest a shortcut for the development of small diameter, tubular-type, nanofiber blood vessels using a biodegradable material (PLGA).

Effects of CNTs waviness and aspect ratio on vibrational response of FG-sector plate

  • Tahouneh, Vahid
    • Steel and Composite Structures
    • /
    • v.25 no.6
    • /
    • pp.649-661
    • /
    • 2017
  • This paper is motivated by the lack of studies in the technical literature concerning to the influence of carbon nanotubes (CNTs) waviness and aspect ratio on the vibrational behavior of functionally graded nanocomposite annular sector plates resting on two-parameter elastic foundations. The carbon nanotube-reinforced (CNTR) plate has smooth variation of CNT fraction based on the power-law distribution in the thickness direction, and the material properties are also estimated by the extended rule of mixture. In this study, the classical theory concerning the mechanical efficiency of a matrix embedding finite length fibers has been modified by introducing the tube-to-tube random contact, which explicitly accounts for the progressive reduction of the tubes' effective aspect ratio as the filler content increases. Parametric studies are carried out to highlight the influence of CNTs volume fraction, waviness and aspect ratio, boundary conditions and elastic foundation on vibrational behavior of FG-CNT thick sectorial plates. The study is carried out based on three-dimensional theory of elasticity and in contrary to two-dimensional theories, such as classical, the first- and the higher-order shear deformation plate theories, this approach does not neglect transverse normal deformations. The annular sector plate is assumed to be simply supported in the radial edges while any arbitrary boundary conditions are applied to the other two circular edges including simply supported, clamped and free. For an overall comprehension on 3-D vibration of annular sector plates, some mode shape contour plots are reported in this research work.

Paraovarian Serous Borderline Tumor: A Case Report (난소위체에서 발생한 장액성 경계성 종양: 증례 보고)

  • Hwang, Eun Taeg;Kim, See Hyung;Kim, Mi Jeong;Kang, Yu Na
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.337-339
    • /
    • 2018
  • Parovarian cyst is usually simple cyst, and accounts for 10%-20% of adnexal masses. Borderline or malignant parovarian tumor is rare, and it contains papillary projection at the smooth inner wall. We report the ultrasonography, CT and MRI findings of a parovarian serous borderline tumor in 19-year-old female presenting left lower quadrant abdominal discomfort for 2 days.

Experimental study on heat transfer characteristics of supercritical carbon dioxide natural circulation

  • Wang, Pengfei;Ding, Peng;Li, Wenhuai;Xie, Rongshun;Duan, Chengjie;Hong, Gang;Zhang, Yaoli
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.867-876
    • /
    • 2022
  • An experimental study has been conducted to investigate the heat transfer characteristics of supercritical carbon dioxide (sCO2) uniformly heated in the horizontal circular smooth tube. The results illustrated that there was a significant difference in heat transfer between the top wall and bottom wall due to the buoyancy. Bulk flow acceleration cannot be negligible in the high heat flux region, which leads to heat transfer deterioration. A new heat transfer correlation is proposed, in which the buoyancy parameter and bulk flow acceleration have been taken into account. The new correlation and six classic correlations for sCO2 are examined in horizontal tubes. The comparison indicates that the new correlation has a better performance for sCO2 flowing through a horizontal heating tube under natural circulation conditions. For example, 94.9% of the calculated results using the new heat transfer correlation were within ±30% of the experimental results while only 87.9% of that using the Jackson correlation (the best of the six) were within the same error bands.

A taxonomic study of the genus Hosta in Korea (한국산 비비추속(Hosta Tratt.) 식물의 분류학적 연구)

  • Jo, Hyun;Kim, Muyeol
    • Korean Journal of Plant Taxonomy
    • /
    • v.47 no.1
    • /
    • pp.27-45
    • /
    • 2017
  • A taxonomic study of the genus Hosta (Lilliaceae) in Korea was conducted based on morphological characteristics. Hosta clausa varieties share several characteristics (rhizomes with underground stolons, smooth scapes, and purple anthers). Hosta clausa var. normalis has an open perianth, long pistils, and fertile fruit. H. clausa var. clausa can be distinguished from H. clausa var. normalis by its closed perianth and sterile fruit. H. clausa var. geumgangensis has sterile fruit, green petioles, short pistils, and short narrow perianth tubes. H. clausa var. ensata has very narrow, sword-shaped leaves. It can be included in H. clausa var. normalis, which has a large degree of variation in leaf and petiole shape. H. jonesii has smooth scapes, yellow anthers, and bell-shaped flowers. It can be distinguished from the related species H. tsushimensis found on the Tushima islands in Japan by its wide perianth tube. H. yingeri is distinguished by its funnel-shaped flowers, 3 long and 3 short stamens, and smooth scape; the related species H. laevigata has 6 equally-sized stamens, narrowly lanceolate leaves, and wavy leaf margins. Because H. laevigata is not found in its type locality Isl. Heugsando, its taxonomic position must be determined at a later time. H. minor shares several characteristics (scapes with ridges and yellow-colored anthers) with the related taxa H. venusta. However, H. venusta is changed to H. minor var. venusta because it has overlapping characteristics in plant size, number of flowers, leaf size, and leaf shape. Consequently, the genus Hosta in Korea is classified into 5 species, 3 varieties, and 6 forms.

Evaporation Heat Transfer and Pressure Drop of R-410A in a 7.0 mm O.D. Microfin Tube at Low Flow Rates (낮은 유량에서 외경 7.0 mm 마이크로핀 튜브 내 R-410A 증발 열전달 및 압력 손실)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.9
    • /
    • pp.761-772
    • /
    • 2015
  • Microfin tubes having an outside diameter (O.D.) of 7.0 mm are widely used in residential air conditioning systems and heat pumps. It is known that the mass fluxes for air conditioners and heat pumps under partial load conditions are several tens of $kg/m^2s$. However, literature surveys reveal that previous investigations were limited to mass flux over $100kg/m^2s$. In this study, we conduct R-410A evaporation heat-transfer tests at low mass fluxes ($50-250kg/m^2s$) using a 7.0 mm O.D. microfin tube. During the test, the saturation temperature was maintained at $8^{\circ}C$, and the heat flux was maintained at $4.0kW/m^2$. For comparison purposes, we also test a smooth tube with a 7.0 mm O.D. The results showed that the heat-transfer enhancement factor of the microfin tube increased as the mass flux decreased up to $150kg/m^2s$, which decreased as the mass flux further decreased. The reason for this was attributed to the change of the flow pattern from an annular flow to a stratified flow. Within the test range, the frictional pressure drops of the microfin tube were approximately the same as those of the smooth tube. We then compare experimental data obtained with the predictions obtained for the existing correlations.