• Title/Summary/Keyword: Smoke reduction

Search Result 190, Processing Time 0.023 seconds

Estimation of the Medium Transmission Using Graph-based Image Segmentation and Visibility Restoration (그래프 기반 영역 분할 방법을 이용한 매체 전달량 계산과 가시성 복원)

  • Kim, Sang-Kyoon;Park, Jong-Hyun;Park, Soon-Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.163-170
    • /
    • 2013
  • In general, images of outdoor scenes often contain degradation due to dust, water drop, haze, fog, smoke and so on, as a result they cause the contrast reduction and color fading. Haze removal is not easier problem due to the inherent ambiguity between the haze and the underlying scene. So, we propose a novel method to solve single scene dehazing problem using the region segmentation based on graph algorithm that has used a gradient value as a cost function. We segment the scene into different regions according to depth-related information and then estimate the global atmospheric light. The medium transmission can be directly estimated by the threshold function of graph-based segmentation algorithm. After estimating the medium transmission, we can restore the haze-free scene. We evaluated the degree of the visibility restoration between the proposed method and the existing methods by calculating the gradient of the edge between the restored scene and the original scene. Results on a variety of outdoor haze scene demonstrated the powerful haze removal and enhanced image quality of the proposed method.

Assessing Health Impacts of Pictorial Health Warning Labels on Cigarette Packs in Korea Using DYNAMO-HIA

  • Kang, Eunjeong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.4
    • /
    • pp.251-261
    • /
    • 2017
  • Objectives: This study aimed to predict the 10-year impacts of the introduction of pictorial warning labels (PWLs) on cigarette packaging in 2016 in Korea for adults using DYNAMO-HIA. Methods: In total, four scenarios were constructed to better understand the potential health impacts of PWLs: two for PWLs and the other two for a hypothetical cigarette tax increase. In both policies, an optimistic and a conservative scenario were constructed. The reference scenario assumed the 2015 smoking rate would remain the same. Demographic data and epidemiological data were obtained from various sources. Differences in the predicted smoking prevalence and prevalence, incidence, and mortality from diseases were compared between the reference scenario and the four policy scenarios. Results: It was predicted that the optimistic PWLs scenario (PWO) would lower the smoking rate by 4.79% in males and 0.66% in females compared to the reference scenario in 2017. However, the impact on the reduction of the smoking rate was expected to diminish over time. PWO will prevent 85 238 cases of diabetes, 67 948 of chronic obstructive pulmonary disease, 31 526 of ischemic heart disease, 21 036 of lung cancer, and 3972 prevalent cases of oral cancer in total over the 10-year span due to the reductions in smoking prevalence. The impacts of PWO are expected to be between the impact of the optimistic and the conservative cigarette tax increase scenarios. The results were sensitive to the transition probability of smoking status. Conclusions: The introduction of PWLs in 2016 in Korea is expected reduce smoking prevalence and disease cases for the next 10 years, but regular replacements of PWLs are needed for persistent impacts.

Estimation of Emission and Development of Emission Factor on Greenhouse Gas (CO2) of the Combustion Facilities (연소시설의 온실가스(CO2) 배출량 산정 및 배출계수개발)

  • Kim, Hong-Rok;Jin, Byong-Bok;Yoon, Wan-Woo;Kwon, Young-Sung;Lee, Min-Young;Yoon, Young-Bong;Shin, Won-Geun
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.4
    • /
    • pp.277-283
    • /
    • 2007
  • Since the Kyoto Protocol became into effect, Korea has been expected to be part of the Annex I countries performing the duty of GHG reduction in the phase of post-Kyoto. Therefore, it is necessary to develop emission factors appropriate to Korean circumstances. In order to develop emission factors this study utilized the CleanSYS, which is the real-time monitoring system for industrial smoke stacks to calculate the emission rate of $CO_2$ continuously. In this study, the main focus was on the power generation plants emitting the largest amount of $CO_2$ among the sectors of fossil fuel combustion. Also, an examination on the comparison of $CO_2$ emission was made among 3 generation plants using the different types of fuels such as bituminous coal and LNG; one for coal and others for LNG. The $CO_2$ concentration of the coal fired plant showed Ave. 13.85 %(10,384 ton/day). The LNG fired plants showed 3.16 %(1,031 ton/day) and 3.19 %(1,209 ton/day), respectably. Consequently, by calculating the emission factors using the above results, it was found that the bituminous coal fired power plant had the $CO_2$ emission factor average of 88,726 kg/TJ, and the LNG fired power plants had the $CO_2$ average emission factors of 56,971 kg/TJ and 55,012 kg/TJ respectably which were similar to the IPCC emission factor.

A Verification Study on the Demand Performance of Fabric Duct for Localization Development of Naval Vessel (해군 수상함 국산화개발 천 덕트의 요구성능 검증연구)

  • Jung, Young In;Choi, Sang Min;Jung, Hyun Sub;Sim, Min Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.468-474
    • /
    • 2020
  • Metal ducts for transporting air conditioning and heating inside ships have recently been replaced by cloth ducts that have the advantage of delivering air evenly to the compartments, with excellent noise reduction in major compartments, such as combat command rooms, steering rooms, and sound detector cabins. Since the performance requirements of fabric ducts for vessels are strict, and the entire length of the ducts was imported from Korea, the government wants to create economic effects through localization of fabric ducts. Air permeability and fire prevention performance tests verified the applicability to naval vessels of fabric ducts developed by Hyundai Heavy Industries and HiDact, and performance requirements presented in the POS were verified. As a result of the tests, the fabric ducts met the requirements for air permeability and fireproof performance.

Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Trace Gas Method under the Presence of Some Cross-draft (방해기류 존재시 추적자 가스법을 이용한 푸쉬풀 후드 효율 평가)

  • Kim, Tae-Hyeung;Ha, Hyun-Chul;Kang, Ho-Gyung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.290-301
    • /
    • 2006
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank. Efficiency of push pull hood system is affected by various parameters, such as, cross draft, vessel shapes, tank surface area, liquid temperature. A previous work assisted by flow visualization technique qualitatively showed that a strong cross draft blown from the pull hood to push slot could destroy a stable wall-jet on the surface of tank, resulting in the abrupt escape of smoke from the surface. In this study, the tracer gas method was applied to determine the effect of cross-draft on the capture efficiency qualitatively. A new concept of capture efficiency was introduced, that is, linear efficiency. This can be determined by measuring the mass of tracer gas in the duct of pull hood while the linear tracer source is in between push slot and pull hood. By traversing the linear tracer source from the push slot to the pull hood, it can be found where the contaminant is escaped from the tank. Total capture efficiency can be determined by averaging the linear efficiencies. Under the condition of cross-draft velocities of 0, 0.4, 0.75, 1.05 and 1.47m/s, total capture efficiencies were measured as 97.6, 95.4, 94.6, 92.7 and 70.5% respectively. The abrupt reduction of efficiency with cross-draft velocity of 1.47m/s was due to the destruction of tank surface wall-jet by the counter-current cross-draft. The same phenomenon was observed in the previous flow visualization study. As an alternative to overcome this abrupt efficiency drop, the 20% increase of hood flow rates was tested, resulting in 20% efficiency increase.

Control of Impinging Jet Heat Transfer Using Mesh Screens (메쉬 스크린을 이용한 충돌제트 열전달 제어에 관한 연구)

  • Jo, Jeong-Won;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.722-730
    • /
    • 2001
  • The local heat transfer of an axisymmetric submerged air jet impinging on a heated flat plate is investigated experimentally with the variation of mesh-screen solidity. The screen installed in front of the nozzle exit modifies the flow structure and local heat transfer characteristics. The mean velocity and turbulence intensity profiles of streamwise velocity component are measured using a hot-wire anemometry. The temperature distribution on the heated flat surface is measured with thermocouples. The smoke-wire flow visualization technique was employed to understand the near-field flow structure qualitatively for different mesh screens. Large-scale toroidal vortices and high turbulence intensity enhance the heat transfer rate in the stagnation region. For a higher solidity, turbulence intensity become higher which increases the local heat transfer at small nozzle-to-plate spacings such as L/D<6. The local and average Nusselt numbers of impinging jet from the $\sigma$(sub)s=0.83 screen at L/D=2 are about 5.6∼7.5% and 7.1% larger than those for the case of no screen, respectively. For the nozzle-to-plate spacings larger than 6, however, the turbulence intensities for all tested screens approach to an asymptotic curve and the mean velocity along the jet centerline decreases monotonically. As the nozzle-to-plat spacing increases for high solidity screens, the heat transfer rate decreases due to the reduction in turbulence intensity and jet momentum.

A Study on the Spontaneous Ignition of the Fuel Injected into a Hot Air Stream - Additional Report: Utilization of Diesel Oil and Emulsified Fuel- (高溫空氣流 에 噴射한 噴霧 의 自然燃燒 에 관한 硏究 -속보 : 경유 및 유화핵연료 사용-)

  • 방중철;태전간랑
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.627-637
    • /
    • 1985
  • The combustion process and the performance of a diesel engine are seriously affected by the ignition delay period of the fuel used. Some methods for improving the combustion process in the engine cylinder are to well match the strength of air swirl with the space of sprays in the cylinder, to blend an ignition improver in the fuel, to inject a small amount of auxiliary fuel prior to main injection and so on. Recently, the improvement of fuel economy and the reduction of exhaust smoke and NO have been successfully achieved by supplying diesel engines with emulsified fuel. However, it is very difficult to know real combustion mechanism under such special conditions, because of many factors affecting on the combustion process in practical reciprocating engine. In the present paper, the combustion processes of diesel fuel and emulsion fuel were tried to improve and to observe by making contact with various lean pre-mixtures in the hot air stream duct. This hot air stream method has an advantage that the spontaneous combustion process can be observed under a simplified condition.

Improvement of Emission Performance in a 3.3 Liter DI Diesel Engine by Using Dimethyl Ether Fuel (디메틸에테르 연료를 사용하는 3.3리터 디젤기관의 배기성능 개선)

  • Pyo, Young-Dug;Lee, Young-Jae;Kim, Mun-Heon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.178-185
    • /
    • 2007
  • A study is improvement of power and emission in a inline-pump Dr diesel engine by using Dimethyl ether Fuel. Dimethyl ether (DME) is an oxygenated fuel with a cetane number higher than that of diesel oil. It meets the ULEV emission regulation and reduces the smoke to almost zero when used in a diesel engine. But NOx emission is almost same and CO, THC emissions are lower than that of diesel engine. The emissions aren't satisfied the stronger emission regulation in the further. Generally DOC (Diesel Oxidation Catalyst) is used to reduce CO & THC emissions and EGR (Exhaust Gas Recirculation) system is used to reduce NOx emission. Test results showed that the torque and the power with DME were almost same as those of pure diesel oil, but the brake thermal efficiency increased a little. also the BSEC (Brake Specific Energy Consumption) with DME was similar that of diesel. The test results showed that the DOC was the vary effective method to reduce the CO emission in case of Dimethyl Ether Fuel in diesel engine. But, THC emission is showed a little reduction rates. Also EGR system was the very effective method to reduce the NOx emission in case of Dimethyl Ether Fuel in diesel engine.

Comparisons of Low Temperature Combustion Characteristics between Diesel and Biodiesel According to EGR control (EGR 제어를 통한 디젤 및 바이오디젤의 저온연소 특성 비교)

  • Lee, Yong-Gyu;Jang, Jae-Hoon;Lee, Sun-Youp;Oh, Seung-Mook
    • Journal of ILASS-Korea
    • /
    • v.16 no.3
    • /
    • pp.119-125
    • /
    • 2011
  • Due to the oxygen contents in biodiesel, application of the fuel to compression ignition engines has significant advantages in terms of lowering PM formation in the combustion chamber. In recent days, considerable studies have been performed to extend the low temperature combustion regime in diesel engines by applying biodiesel fuel. In this work, low temperature combustion characteristics of biodiesel blends in dilution controlled regime were investigated at a fixed engine operating condition in a single cylinder diesel engine, and the comparisons of engine performances and emission characteristics between biodiesel and conventional diesel fuel were carried out. Results show that low temperature combustion can be achieved at $O_2$ concentration of around 7~8% for both biodiesel and diesel fuels. Especially, by use of biodiesel, noticeable reduction (maximum 50% of smoke was observed at low and middle loads compared to conventional diesel fuel. In addition, THC(total hydrocarbon) and CO(Carbon monoxide) emissions decreased by substantial amounts for biodiesel fuel. Results also indicate that even though about 10% loss of engine power as well as 14% increase of fuel consumption rate was observed due to lower LHV(lower heating value) of biodiesel, thermal efficiencies for biodiesel fuel were slightly elevated because of power recovery phenomenon.

An analytical study on the fire characteristics of the small tunnel with large smoke exhaust port (대배기구 배연방식을 적용한 소형차 전용 터널의 화재특성에 관한 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rhee, Kwan-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.375-388
    • /
    • 2017
  • In order to solve the traffic congest and environmental issues, small-cross section tunnel for small car only is increasing, but there is not standard for installation of disaster prevention facility. In this study, in order to investigate the behavioral characteristics of thermal environment and smoke in a small cross section tunnels with a large port exhaust ventilation system, the A86, the U-Smartway and the Seobu moterawy tunnel, Temperature and CO concentration in case of fire according to cross sectional area, heat release rate and exhaust air flow rate were analyzed by numerical analysis and the results were as follows. As the cross-sectional area of the tunnel decreases, the temperature of the fire zone increases and the rate of temperature rise is not significantly affected by heat release rate. However, there is a difference depending on the change of the exhaust air flow rate. In the case of applying the exhaust air flow rate $Q_3+2.5Ar$ of the large port exhaust ventilation system, the temperature of the fire zone was 7.1 times for A86 ($Ar=25.3m^2$) and 5.4 time for U-smartway ($Ar=37.32m^2$) by Seobu moterway tunnel ($Ar=46.67m^2$). The CO concentration of fire zone also showed the same tendency. The A86 tunnels were 10.7 times and the U-Smartways were 9.5 times more than the Seobu moterway. Therefore, in the case of a small section tunnel, the thermal environment and noxious gas concentration due to the reduction of the cross-sectional area are expected to increase significantly more than the cross-sectional reduction rate.