건물화재시 연기층의 형성에 관한 실험적연구 (An Experimental Study on the Formation of Smoke Layer of Compartment Fire)

  • 허만성
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.94-100
    • /
    • 1997
  • The objective of this research is to study the formations of smoke layer in case of several furniture fires such as trashcan, carpet, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the trashcan, mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. The descending speed of the interface height was proportioned to the inflammability of the furniture and the spread of the fire. The time required to come down around 1m was within 1-3 minutes. The Interface heights for the furniture fires were around 1m as the steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.25m-0.75m from the floor. The carbon dioxide concentration reached the highest while the oxygen concentration was minimum.

  • PDF

AN EXPERIMENTAL STUDY ON THE FORMATION OF SMOKE LAYER IN COMPARTMENT FIRE

  • Hur, Man-Sung
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.477-483
    • /
    • 1997
  • Experiments have been performed to investigate the formation of smoke layer in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress, and wardrobe in a residential room. As a result of the present investigation, the uniformly distributed fire of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as mattress and wardrobe showed that the ignition and the initial growth period were relatively long. The descending time of the interface heights was within 1-3 minutes to reach around 1m. However, the interface height was lowered to 0.25-0.75m above the floor at the time of the maximum temperature.

  • PDF

우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 - (A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building -)

  • 이세명;윤명오
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.28-41
    • /
    • 2011
  • 우리나라의 피난방화규정은 1962년 건축법 제정 이후 현재에 이르기까지 많은 변화를 겪어 왔다. 그러나, 과거에 비해 화재안전성능이 어느 정도 개선되었는지, 그리고 현재의 규정은 어느 정도의 화재안전성능을 확보하고 있는지에 대한 정량적인 평가가 이루어지지 않고 있다. 이 연구에서는 과거 화재사례로 비추어 화재발생시 인명피해가 높을 것으로 예상되는 숙박시설 중 호텔건물을 모델로 하여 피난방화규정의 제/개정 시기별 화재안전성능을 평가해 보았다. 그 결과 과거에 비해 화재안전성능이 개선되고는 있으나, 특히 저층부분에서의 거실 및 층피난안전성에서 취약함을 확인할 수 있었다. 숙박시설의 경우 재실자의 화재 인지가 늦어 피난시간이 상대적으로 지연되는 문제점이 있기 때문에, 내부마감재료와 방화문 그리고, 방화구획(면적별/층별) 등의 규정을 보완하여 연기층하강시간을 지연시킬 수 있는 현실적인 방안을 마련 할 필요가 있다.

실물터널 화재실험을 통한 터널화재 위험도 평가 (The Risk Assessment of Tunnel Fire Through Real Scale Fire Test)

  • 최준석;최병일;김명배;한용식;장용재;이유환;황낙순;김필영
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.71-76
    • /
    • 2002
  • 실제 터널화재에서의 위험성을 평가하기 위하여, 국내에서 최초로 실물터널 화재실험이 수행되었다. 길이 465m의 터널에서 0.25MW에서 2.5MW까지의 가솔린 풀과 1500cc승용차를 화원으로 사용하였으며, 터널내의 유속을 조정하기 위하여 6대의 제트팬을 설치하였다. 터널내의 온도분포와 연기거동을 살펴보기 위하여 총 86곳의 온도를 측정하였다. 다양한 조건에서의 풀화재와 자동차 화재의 성상을 비교하였으며, 실험 결과 각종 화재 조건에서의 연기의 역류, 하강, 터널 내 온도분포 등과 같은 실제 터널 화재상황에서 피해에 영향을 미치는 각종 인자들을 파악하였다.