• Title/Summary/Keyword: Smoke Evacuation

Search Result 213, Processing Time 0.03 seconds

A Study on Fire and Evacuation simulation analysis for use of Disaster Vulnerable Personal Evacuation Device (재난약자 대피 도움장치 활용을 위한 화재 피난 시뮬레이션 분석 연구)

  • Choi, Doo Chan;Hwang, Hyun Soo;Ko, Min Hyeok;Lee, Si Yu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.824-831
    • /
    • 2020
  • Purpose: In fire case, nursing hospitals are subject to considerable restrictions on evacuation due to the characteristics of occupants and vulnerable elements of buildings, it is important to make evacuation device for vulunerabale person, and need how to intend to increase the efficiency of evacuation by fire and evacuation simulation with helper Method: The smoke characteristics were analyzed by time through fire simulation, finally, the number of helpers according to the day and night was entered, and the evacuation completion time was compared and analyzed using the evacuation simulation. Result: It was found that the evacuation time was shortened by more than 20% when the evacuation assistance device was used for the vulnerable, and the evacuation time was delayed by almost 70% in case of a fire at night compared to the daytime. Conclusion: If the horizontal and vertical evacuation device are effectively utilized in actual fire situations, a strategy appropriate to the situation is deemed necessary. It is expected that evacuation efficiency will increase based on the use of horizontal evacuation evacuation device and vertical evacuation device by developing evacuation manuals

Primary Fire Behavior of Compounded Multiplex Theater with Various Fire Conditions (조합형 복합상영관에서의 화재조건에 따른 초기화재 거동해석)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.1-6
    • /
    • 2007
  • This paper investigated the fire and smoke behavior in the compounded multiplex theater using FDS with various spacial and boundary conditions to ensure the fire safety of the multiplex. The results showed that more rapid temperature increase and smoke can be induced near the exit door for the lower fire load duo to the horizontal smoke movement. The overuse of fire resistants can generate more smoke while delaying combustion rate, which can give adverse effect to the evacuation. The mal-function of the exhaust fan would obstruct smoke exhaust but also retard the function of sprinkler head.

Study of evacuation fire doors in multiple facilities (다중이용시설의 피난방화문에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7380-7384
    • /
    • 2014
  • Evacuation fire doors were manufactured by applying phosphorescent paint to the whole fire door whose performance was already recognized, and applying heat sensitive paint around the grip. The facility was improved by the evacuation and safety functions on the fire door, which has been used as only a fire facility, and the fire door is also used as an evacuation facility. The brilliance of the evacuation safety fire door manufactured in this study passed the brilliance test of Korea Fire Institute with a performance more than the brilliance (7mcd after 60 minutes) of the existing inducement sign. During a fire, the visible area is larger than the evacuation door inducement, etc. and light preventive status in the lower part of the fire door was observed during the descent of smoke. Therefore, it is considered to extend the evacuation effective time of evacuators. In heat sensitive paint applied around the grip, a color change is observed on the fire door when approaching a certain temperature ($70^{\circ}C$). Therefore, the first disaster that evacuators can encounter on the grip of a fire door during a fire can be prevented and should be helpful in recognizing the backfiring possibility and preventing safety accidents for firefighters who must enter a fire space.

The Passenger Evacuation Simulation Using Fluent and EXODUS (Fluent와 EXODUS를 이용한 승객피난 시뮬레이션)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Park, Won-Hee;Jung, Woo-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.95-100
    • /
    • 2008
  • The simulation analysis of fire-driven flow and passenger evacuation in Daegu subway station, Chung-Ang, have been performed. The first location of outbreak of fire is inside passenger car in the third basement in Chung-Aug station, The smoke flow in the second and third basement has been analyzed using FLUENT 6.2. The CO (carbon monoxide) and temperature distribution in the train units and station platform have been obtained and transferred to input data for evacuation simulation. The highest temperature in the train units was 1500k. For the simulation of passenger evacuation, EXODUS has been used for whole basements (level 1${\sim}$level 3) in the station. Total number of people was assumed to be one thousand and 640 were placed inside train and 360 were placed outside train. In evacuation simulation, an average of 135 passengers were killed and an average time to evacuate takes 10min 19sec. The main evacuation routes used by passengers were investigated and the cause of death was identified by evacuation simulation.

An Experimental Study on the Adaption of Announcement Based Evacuation Guidance System using Haas Effect in Large Space (대규모 공간에서 선행음 효과를 이용한 음성피난유도 시스템의 적용연구)

  • Baek, Eun-Sun;Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Kook, Chan
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.100-107
    • /
    • 2011
  • In this study, a simulated situation in which the visions of the evacuees were blocked by the smoke, which is one of the most dangerous factors that cause casualties in case of an emergency, was conducted for the evaluation of the performance of an evacuation guidance system. For this purpose, the behavior and time taken by the experiment subjects in simulated evacuation test were measured and analyzed. When the evacuation guidance sound signals were given by 4 speakers at the same time, most of the subject were disoriented and took generally longer in getting to the pre-designated evac point. And, using only one speaker instead of two showed a better result in terms of the evacuation behavior or and orientation. Also, when there were two or more speakers used for the broadcasting of the guidance message, it turned out that using Hass effect, and placing the speakers closer, could result in higher awareness of the guidance message and maintenance of the orientation, while it also made the subjects took short to get to the evac point.

Analysis of Performance-based Design Guides of Smoke Control System (성능위주 연기제어 설계지침 분석)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.6-13
    • /
    • 2016
  • With regard to smoke control system, the design guidelines of smoke exhaust for accommodation and smoke control for evacuation stairs and vestibule has been proposed domestically, but after reviewing the applicability to modern buildings that tend to be larger, higher and complex, a smoke control system according to domestic design guidelines might have difficulty in securing the safety from smoke in a fire. Therefore, it is necessary to adopt the performance-based design of a smoke control system that can enhance the safety and integrate the smoke control functions and design depending on the characteristics of fire and building structure in the case of fire in a large, high-rise, and complex building. This study analyzed the domestic design guidelines of a smoke control system and this paper proposes the part requiring improvement, and examines the legal system and guidelines on performance-based design of smoke control system in foreign countries.

A study on the effective fire and smoke control in transverse oversized exhaust ventilation (횡류식 선택대배기환기에서의 배연특성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.451-462
    • /
    • 2011
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume with scaled-model and simulation when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250 m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

A Study on Heat and Smoke Exhaust Characteristics from the Subway Fire for Different Ventilation Modes (지하철 화재시 제연모드에 따른 열 및 연기 배출 특성 연구)

  • Chang, Hee-Chul;Yoon, Kyung-Beom;Park, Won-Hee;Kim, Tae-Kuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.37-42
    • /
    • 2008
  • This study is focused on the numerical predictions for different smoke-control ventilation modes for the subway fire. Smoke-control ventilation mode in the domestic platform is that exhausting for the smoke detected zones while supplying air or stopping any ventilation for other zones in the platform. Three cases of smoke control ventilation modes are considered. First and second case are present running smoke control mode in Korea. The third is that smoke-control ventilation fans equipped in the platform are operated in first 4 minute(platform evacuation time, NFPA130) since then the fans equipped in the platform are stopped and the fans equipped in the tunnels are operated. Distributions of heat, carbon monoxide and visible range are compared at a height of 1.7m(passenger breath/sight height) above the platform. The numerical results show that air supply fan operation in the platform causes the smoke disturbance and a rapid spread of the smoke. The switch-operation with fans in both the platform and tunnel are better than operation with only platform fans in smoke rejection efficiency.

A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation (Oversized Exhaust System) (도로터널 화재시 반횡류식 환기방식에서의 최적배연 연구(대배기구 방식))

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.79-84
    • /
    • 2009
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75m/s and 2.5m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.