• 제목/요약/키워드: Smart-Grid

검색결과 1,002건 처리시간 0.027초

에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용 (Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction)

  • 임일형;이명환;신용학
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

LSTM을 이용한 웹기반 수용가별 전력수요 변동성 평가시스템 (Web based Customer Power Demand Variation Estimation System using LSTM)

  • 서덕희;유준수;최은정;조수환;김동근
    • 한국정보통신학회논문지
    • /
    • 제22권4호
    • /
    • pp.587-594
    • /
    • 2018
  • 본 연구는 LSTM기반의 전력수요 변동성 평가 시스템을 제안하고 핵심모듈인 수요예측모듈의 정확성을 증명하기 보다는 실제 전력수요 모니터링 시스템 내 딥러닝을 이용하여 갑작스러운 전력패턴의 변화를 인지할 수 있는 모듈에 대한 활용 가능성을 확인하고자 한다. 웹기반 시스템에 모듈로 적용하여 관리자가 전력사용 패턴의 변동성을 판단할 수 있도록 시각화된 보고서를 제공하였다. 변동성 평가시스템의 구현 결과 관공서와 병원 등의 기관의 경우 전력사용량 데이터가 일정한 형태의 패턴을 보임을 확인하였다. 반면 주거시설과 같이 전력사용량이 상대적으로 낮은 지역의 경우 변동성 평가에는 적절하지 않았음을 확인했다.

스마트 그리드를 위한 홈 에너지 절감 시스템의 IEC 국제표준화 및 구현 (International Standardization and Implementation of Home Energy Saving System for Smart Grid)

  • 최광순;이상원;박영충;정광모
    • 한국통신학회논문지
    • /
    • 제37C권12호
    • /
    • pp.1222-1229
    • /
    • 2012
  • 가정 및 빌딩에서의 에너지 소비 절감 및 효율 향상을 위한 에너지 절감 시스템(ESS)의 새로운 구조와 기능 요구사항을 정의하는 신규 국제표준 제안서를 2009년에 IEC TC 100에 제안하고 최종 IEC PT 62654라는 신규 프로젝트로 채택이 되었다. 최근 표준 발간을 위한 최종 투표에서 만장일치로 통과함에 따라 2012년 8월 IEC TS 62654 규격이 발간되었다. 표준의 검증을 위해 ESS 서버, ESS 클라이언트, 휴대용 ESS 터미널로 구성되는 ESS 시스템의 프로토타입을 표준화 과정과 병행하여 구현하였으며, 또한 ESS 서버와 클라이언트간 통신을 위한 EPCM 프로토콜을 구현하였다. EPCM 프로토콜은 ESS 네트워크의 자동 구성, 전력 소비 모니터링, 원격 전원 제어 및 지능적인 에너지 절감 서비스를 위한 부가 기능들을 지원한다.

CIM 기반 AMI용 미터데이터관리시스템(MDMS) 개발 방안 연구 (Study on Development Method of MDMS for AMI Operation based on Common Information Model)

  • 정남준;진영택;채창훈;최민희
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제1권3호
    • /
    • pp.171-180
    • /
    • 2012
  • 전력시스템의 배전분야 정보모델 및 데이터교환 국제표준인 CIM(Common Information Model, IEC61968) 기반 MDMS(Meter Data Management System, 미터데이터관리시스템) 개발에 있어서, 가장 중점을 두는 부분은 짧은 주기로 수집되는 데이터의 효과적인 관리와 AMI 데이터를 활용하기 위하여 상위시스템들과 어떻게 통합서비스 할 것인가에 대한 이슈이다. 본 논문에서는 기존의 AMR 환경과 다르게 양방향 서비스 인프라를 제공하는 AMI 환경에서 MDMS 구현 방안과 기능들을 제안한다. 본 논문에서 제안하는 MDMS의 특징은 국제전력표준인 CIM과 통합서비스버스(ESB)를 활용하여 상호운영성을 확보했다는 점과 컴포넌트 기반으로 시스템 모듈을 구현하여 현장 활용도 향상이 가능하다는 점이다. 본 연구의 제안된 결과는 지능형전력망 구현에 있어서 CIM 기반 전력시스템의 효율적인 개발 및 운영에 기여할 것으로 기대한다.

Intracellular $Ca^{2+}$ Mobilization and Beta-hexosaminidase Release Are Not Influenced by 60 Hz-electromagnetic Fields (EMF) in RBL 2H3 Cells

  • Hwang, Yeon-Hee;Song, Ho-Sun;Kim, Hee-Rae;Ko, Myoung-Soo;Jeong, Jae-Min;Kim, Yong-Ho;Ryu, Jeong-Soo;Sohn, Uy-Dong;Gimm, Yoon-Myoung;Myung, Sung-Ho;Sim, Sang-Soo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제15권5호
    • /
    • pp.313-317
    • /
    • 2011
  • The effects of extremely low frequency electromagnetic fields (EMF) on intracellular $Ca^{2+}$ mobilization and cellular function in RBL 2H3 cells were investigated. Exposure to EMF (60 Hz, 0.1 or 1 mT) for 4 or 16 h did not produce any cytotoxic effects in RBL 2H3 cells. Melittin, ionomycin and thapsigargin each dose-dependently increased the intracellular $Ca^{2+}$ concentration. The increase of intracellular $Ca^{2+}$ induced by these three agents was not affected by exposure to EMF (60 Hz, 1 mT) for 4 or 16 h in RBL 2H3 cells. To investigate the effect of EMF on exocytosis, we measured beta-hexosaminidase release in RBL 2H3 cells. Basal release of beta-hexosaminidase was $12.3{\pm}2.3%$ in RBL 2H3 cells. Exposure to EMF (60 Hz, 0.1 or 1 mT) for 4 or 16 h did not affect the basal or $1{\mu}m$ melittin-induced beta-hexosaminidase release in RBL 2H3 cells. This study suggests that exposure to EMF (60 Hz, 0.1 or 1 mT), which is the limit of occupational exposure, has no influence on intracellular $Ca^{2+}$ mobilization and cellular function in RBL 2H3 cells.

Power Curve of a Wind Generator Suitable for a Low Wind Speed Site to Achieve a High Capacity Factor

  • Yoon, Gihwan;Lee, Hyewon;Lee, Sang Ho;Hur, Don;Cheol, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.820-826
    • /
    • 2014
  • It is well known that energy generated by a wind generator (WG) depends on the wind resources at the installation site. In other words, a WG installed in a high wind speed area can produce more energy than that in a low wind speed area. However, a WG installed at a low wind site can produce a similar amount of energy to that produced by a WG installed at a high wind site if the WG is designed with a rated wind speed corresponding to the mean wind speed of the site. In this paper, we investigated the power curve of a WG suitable for Korea's southwestern coast with a low mean wind speed to achieve a high capacity factor (CF). We collected the power curves of the 11 WGs of the 6 WG manufacturers. The probability density function of the wind speed on Korea's southwestern coast was modeled using the Weibull distribution. The annual energy production by the WG was calculated and then the CFs of all of the WGs were estimated and compared. The results indicated that the WG installed on the Korea's southwestern coast could obtain a CF higher than 40 % if it was designed with the lower rated speed corresponding to the mean wind speed at the installation site.

효율적인 전력선통신 라우팅 경로 탐색 기법 (An Efficient Routing Path Search Technique in Power Line Communication)

  • 서충기;김준하;정준홍
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1216-1223
    • /
    • 2018
  • As field of application of AMI, AMR uses the power line as the primary means of communication. PLC has a big merit without installation of the new network for communication in a field using the power line which is the existing equipment. However, there is a serious obstacle in commercialization for the instability by noise and communication environment. Therefore, the technical method for maintaining the communication state which overcome such demerit and was stabilized is required essentially. PLC routing technology is applied with the alternative plan now. The routing technology currently managed by field includes many problems by applying the algorithm of an elementary level. PLC routing path search problem can be modeled with the problem of searching for optimal solution as similar to such as optimal routing problem and TSP(Travelling salesman problem). In this paper, in order to search for a PLC routing path efficiently and to choose the optimal path, GA(Genetic Algorithm) was applied. Although PLC was similar in optimal solution search as compared with typical GA, it also has a difference point by the characteristic of communication, and presented the new methodology over this. Moreover, the validity of application technology was verified by showing the experimental result to which GA is applied and analyzing as compared with the existing algorithm.

위협모델링을 이용한 전기차 충전 인프라의 보안요구사항에 대한 연구 (A Study on Security Requirements of Electric Vehicle Charging Infrastructure Using Threat Modeling)

  • 차예슬;김승주
    • 정보보호학회논문지
    • /
    • 제27권6호
    • /
    • pp.1441-1455
    • /
    • 2017
  • 전기차 충전 인프라에서는 충전 및 결제 데이터를 포함하여 다양한 데이터가 전송되기 때문에 안전한 전기차 충전 인프라를 구축하기 위해서는 이에 대한 보안 연구가 요구된다. 그렇지만 기존에 진행된 연구들은 전기차 충전을 위한 충전 인프라 보다는 전력 계통 인프라와 같은 스마트 그리드 관련 보안 연구가 주를 이루고 있다. 또한 충전 인프라 관련 연구는 아직 부족한 현실이며, 위협모델링과 같은 체계적인 방법론을 이용한 연구는 아직 진행되고 있지 않다. 따라서 안전한 전기차 충전 인프라의 구축을 위해 위협모델링을 적용하여 보안 위협을 식별하고 보안요구사항을 체계적으로 분석하는 것이 필요하다. 본 논문에서는 Data Flow Diagram, STRIDE, Attack Tree를 활용한 위협모델링을 이용하여 충전 인프라에서 발생 가능한 위협을 정확히 식별하고 객관적인 보안요구사항을 도출하여 전기차 충전 인프라를 분석한다.

SF6, g3 및 Dry Air 절연에서 PD 특성 비교 분석 (Comparative Analysis of PD Characteristics Under SF6, g3 and Dry Air Insulation)

  • 신한신;김남훈;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.490-494
    • /
    • 2020
  • Sulphur hexafluoride (SF6) is mostly used as a current-insulating medium in gas-insulated switchgears (GIS), owing to its excellent dielectric strength and arc-extinguishing performance. The global warming potential (GWP) of SF6, however, is 23,900 times that of CO2, and its life time in the atmosphere is 3,200 years. For these reasons, new eco-friendly gases to replace SF6 are required. In this study, the partial discharge (PD) characteristics of green gas for grid (g3) and dry air (N2/O2) were analyzed to compare with those of SF6. A PD electrode system was designed to simulate the protrusion defect in GISs and fabricated for experimentation. To compare the PD characteristics of each gas, the discharge inception voltage (DIV), discharge extinction voltage (DEV), discharge magnitude, discharge pulse number, and phase pattern were analyzed. Results from this study are expected to provide fundamental materials for the design of eco-friendly GISs.

스마트워터그리드내 빗물이용방안 연구 (Study on Rainwater Using in Smart Water Grid)

  • 김만식;이호선;정승권;이수원
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.261-261
    • /
    • 2015
  • 지금까지 빗물에 대한 일반인들의 인식은 모두 치수에 중심을 두어왔다. 즉, 빗물은 내리자마자 곧바로 하수도를 통해 방류수역으로 신속하게 배제해야한다 것에만 관심을 두어 왔던 것이다. 이러한 문제점을 해결하기 위해 빗물을 버리고 배제하기보다 필요한 곳에서 집수하여 활용하거나 적절히 침투 또는 저류하여 물을 효과적으로 제어 관리해야할 필요성이 대두되고 있다. 안정적인 수자원 확보 및 공급에 대한 사회적 요구가 증가됨에 따라 대체방안으로서의 빗물이용관리가 제기되고 있으며, 이는 도시화 및 인구의 도서집중, 경제활동의 고도화 등 물 사용량이 증대되는 생활방식에 따라 물 공급 중단에 따른 피해 잠재성이 증가되고 있음을 의미하기도 한다. 본 과제에서는 이러한 필요성을 감안하여 대체수자원으로서의 빗물을 이용한 수자원 확보방안에 대해 연구하고, 스마트 워터그리드 관점에서의 빗물이용방안을 제시하여 그 적용성을 평가하고자 한다. 본 연구를 수행하기 위해서는 기존 대체수자원의 확보기술을 조사하고, 이를 바탕으로 다양한 수원을 통한 수자원 확보방안을 제시하고, 이 중 빗물을 이용한 수자원 확보방안에 대하여 스마트워터그리드 관점에서의 적용성을 평가하였다. 스마트워터그리드 내에서의 빗물이용을 통한 대체수자원 적용성 평가는 도서지역의 제한급수 등 물 부족 문제 해결을 위한 방안과 산간 농업지역에서의 물부족으로 인한 농작물 생산활동의 저하문제를 해결하기 위한 방안을 제시하였다. 또한 수자원확보를 위한 적정 빗물이용법 도출을 위해 최근 물 관리 패러다임의 변화를 고려한 정책사업으로의 접근, 중앙정부와 지방정부의 노력, 정부-민간 협동체계 구축을 위한 지역전문가의 활동방법 등을 제시하고자 한다. 본 연구의 결과 스마트워터그리드 체계구축을 위한 여러 요소기술 중 다중수원을 통한 용수확보 방안에서 빗물(우수)을 이용한 대체수자원 확보방안을 정립하고, 이를 이용하여 도서지역에서의 제한급수문제 해결방안과 산간 농업지역에서의 농업용수 확보방안을 제시할 수 있을 것이다.

  • PDF