• Title/Summary/Keyword: Smart illuminating system

Search Result 38, Processing Time 0.024 seconds

The Influence of Permanent Magnet on the Bouncing of Latching Relay (자기유지형 릴레이 바운싱의 영구자석 영향)

  • Ryu, Jae-Man;Choi, Sun-Ho;Huh, Chang-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.41-47
    • /
    • 2013
  • The electrical relay in an essential part of the Smart Grid, Electrical Vehicle (EV) and LED lightning system. For these reasons, research of electrical relay is actively underway. In this paper, analyze of the relationship between the bouncing of relay contact and magnetic flux of permanent magnet. Experiment result, changes the bouncing numbers depending on the magnetic flux of the latching relay. And find the value of the magnetic flux that occurs to minimize the bouncing of the contacts. In additions, by the increasing the magnetic flux, unconditional bounce is not reduced. The bouncing number of latching relay is less than expected the armature relay for present results. Further experiments are need to prove it, bouncing on the armature relays.

A Variable Step Size Incremental Conductance MPPT of a Photovoltaic System Using DC-DC Converter with Direct Control Scheme

  • Cho, Jae-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.74-82
    • /
    • 2013
  • This paper presents a novel maximum power point tracking for a photovoltaic power (PV) system with a direct control plan. Maximum power point tracking (MPPT) must usually be integrated with photovoltaic (PV) power systems so that the photovoltaic arrays are able to deliver maximum available power. The maximum available power is tracked using specialized algorithms such as Perturb and Observe (P&O) and incremental Conductance (indCond) methods. The proposed method has the direct control of the MPPT algorithm to change the duty cycle of a dc-dc converter. The main difference of the proposed system to existing MPPT systems includes elimination of the proportional-integral control loop and investigation of the effect of simplifying the control circuit. The proposed method thus has not only faster dynamic performance but also high tracking accuracy. Without a conventional controller, this method can control the dc-dc converter. A simulation model and the direct control of MPPT algorithm for the PV power system are developed by Matlab/Simulink, SimPowerSystems and Matlab/Stateflow.

Development of Smart Remote Terminal Unit for Water Treatment SCADA System (상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

A Novel Development of Distributed Intelligent Control Module Based on the LonWorks Fieldbus for Air Handling Units in the Healing, Ventilating and Air Conditioning (LonWork fieldbus 기반을 가진 HVAC 공기조화기용 고성능 지능형제어모듈 개발)

  • 홍원표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2004
  • In this paper, a new distributed intelligent control module based on LonWoks fieldbus for air handling unit(AHU) of heating, ventilating and air-conditioning(HVAC) is proposed to replace with a conventional direct digital control(DDC) system with 32 bit microprocessor. The proposed control architecture has a excellent features such as highly compact and flexible function design, a low priced smart front-end and reliable performance with various functions. This also addresses issues in control network configuration, logical design of field devices by S/W tool, Internet networking and electronic element installation. Experimental results for showing the system performance are also included in this paper.

Strategy of Market Spread-Commercialization in EVs Industry : Visegrad and Nordic Countries (EVs 산업의 시장파급과 상용화의 전략비교 : 비셰그라드 그룹과 북유럽 협의체와의 산업역량중심으로)

  • Seo, Dae-Sung
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.3
    • /
    • pp.57-68
    • /
    • 2018
  • Purpose - The purpose of this study is to classify that the quality factors for comparing the Visegrard Group with the Nordic Council have historical similarities against Germany and the Soviet Union. However, this is because in the integrated European market, the competitiveness possessed by the two groups of countries is invested in the priority order to grow. Research design, data, and methodology - The study was conducted on the research design, and the reason for trying to compare the competence of the automobile industry in the assessment of industrial capability is that the Visegrard Group focuses on automotive production and the Nordic Association focuses on the commercialization of the automobile(market). In this study, searching and quantifying indirect evidence was made through standards are more complementary in Europe since each country acts like the role of the European automotive industry for example, which is different from the realistic evaluation criteria, are more important than those of the United States(first in the world) or Germany(first in Europe). Results - The results of this study are as follows: In the global EV market U.S.(export: $ 2.62 billion /share: 36.7%), Germany($ 1.29 billion /18.1%), France($ 390 million /5.4%), United Kingdom($ 380 million /5.4%), and South Korea($ 320 million/ 4.4%). South Korea's share of the EV market is 4.4%, while TSI reaches at +0.9 which measures the comparative advantage of a specific commodity in the world trade market. There is great potential for evaluated as products processing in export competition. But, commercialization, standardization, and overall market expansion did not have a positive impact on global satisfaction. Conclusions - EVs put importance on various utilities. So this suggests that Korea's exports to the EU, including the Visegrard Group, should be more focused on marketability when illuminating with a sharing industrial system under the European Union. It is necessary to specialize in manufacturing and commercialization by country(region) to prepare sharing economy and blockchain in order to create a smart-sharing city linked on artificial intelligence, as the commercialization of electric vehicles, which will have a larger growth rate than that of manufacturing in the fourth revolutionary era.

A Study on the Battery Storage Volume Optimization in case of DR Participation for the Minimization of the Customer's Investment Cost (BESS의 DR(Demand Response) 적용 시 수용가의 투자비 최소화를 위한 적정용량산출방법)

  • Yang, Seung-Kwon;Kim, Dae-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2013
  • The BESS(Battery Energy Storage System) is an useful device for load leveling, but the high cost, installation space and safety issues are the main barriers for supplying it widely. The important factor in supplying BESS to customers successfully is the payback period. As most of the H/W cost factors are uncontrollable, the optimization of storage volume can be useful factor in improving payback period. In order to obtain optimized BESS volume, the load factor, demand ratio, peak shaving ratio, electric rates and benefits from DR participation of customer should be analyzed. In this paper, we could verify the peak cutting capability and cost effectiveness under the some proposed conditions and changing value of PCS and battery based on the customers data after volume optimization process was applied, and we can identified the saturation point of load factor and shortening of customer's payback period.

Dimmable Spatial Intensity Modulation for Visible-light Communication: Capacity Analysis and Practical Design

  • Kim, Byung Wook;Jung, Sung-Yoon
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.532-539
    • /
    • 2018
  • Multiple LED arrays can be utilized in visible-light communication (VLC) to improve communication efficiency, while maintaining smart illumination functionality through dimming control. This paper proposes a modulation scheme called "Spatial Intensity Modulation" (SIM), where the effective number of turned-on LEDs is employed for data modulation and dimming control in VLC systems. Unlike the conventional pulse-amplitude modulation (PAM), symbol intensity levels are not determined by the amplitude levels of a VLC signal from each LED, but by counting the number of turned-on LEDs, illuminating with a single amplitude level. Because the intensity of a SIM symbol and the target dimming level are determined solely in the spatial domain, the problems of conventional PAM-based VLC and related MIMO VLC schemes, such as unstable dimming control, non uniform illumination functionality, and burdens of channel prediction, can be solved. By varying the number and formation of turned-on LEDs around the target dimming level in time, the proposed SIM scheme guarantees homogeneous illumination over a target area. An analysis of the dimming capacity, which is the achievable communication rate under the target dimming level in VLC, is provided by deriving the turn-on probability to maximize the entropy of the SIM-based VLC system. In addition, a practical design of dimmable SIM scheme applying the multilevel inverse source coding (MISC) method is proposed. The simulation results under a range of parameters provide baseline data to verify the performance of the proposed dimmable SIM scheme and applications in real systems.

A Study on the Method to Evaluate Minimum Capacity of Energy Storage System(ESS) for Micro Grid(MG) Design (확률론적 방법론을 이용한 마이크로그리드(MG)의 에너지 저장장치(ESS) 최소 필요용량 및 투자시점 결정방법)

  • Lee, Jae-Gul;Shin, Jeong-Hoon;Nam, Su-Chul;Baek, Sung-Muk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.40-47
    • /
    • 2010
  • In this paper, we propose a probability method to determine minimum capacity of energy storage system(ESS) for Micro Grid(MG). Because of high capital cost of ESS, it's very important to determine optimal capacity of ESS and for stable operation of MG and we should determine minimum capacity of ESS. The proposed method has abilities to consider forced outage rate of generators and intermittent of non-dispatchable generators and minimum capacity make MG keep energy balancing by oneself.