• Title/Summary/Keyword: Small-signal

Search Result 2,289, Processing Time 0.036 seconds

Rock Slope Monitoring using Acoustic Emission (미소파괴음을 이용한 절토사면계측)

  • Jang, Hyun-Ick;Kim, Jin-Kwang;Kim, Chan-Woo;Kim, Kyung-Suk;Cheon, Dae-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.743-748
    • /
    • 2010
  • The stability forecasting of rock slope is more difficult than soil slope because catching the sign of failure in monitoring is not easy and deformation of the rock is small in failure process. But in the rock slope, there is small deformation like crack propagation in rock itself and it accumulates gradually in failure process. If it is possible to detect the small change in the rock slope, we can know the failure time exactly. Because the individual signal is gathered in the acoustic emission monitoring, it is possible to monitoring the slope if many sound signal is accumulated. Detection test of acoustic emission was performed. Uniaxial, two types of bending test, and two plane shear test were done with various cement paste sample. Wave propagation velocity of uniaxial test sample was increased with curing time. Wave Analysis give us the result that there is a AE sign signal before the failure, the AE count is suddenly increased. And frequency level 125kHz before failure is changed to level 200-250kHz after failure. In two plane shear test we can catch the AE signal and can know the failure type from wave shape. Monitoring test site is tunnel slope in Hongcheon but special signal is not collected.

  • PDF

Large Signal Unified Model for GaAs pHEMT using Modified Curtice Model (새롭게 수정된 Curtice 모델을 이용한 GaAs pHEMT 대신호 통합모델 구축)

  • 박덕종;염경환;장동필;이재현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.551-561
    • /
    • 2001
  • In this paper, the large signal unified model is established for H4O GaAs pHEMT of GEC-Marconi using modified Curtice model. This unified model includes DC characteristic, small signal, and noise characteristic as various bias. Particularly, the model can simply and physically explain trans-conductance $(g_m)$ of pHEMT using modified Curtice model, and can tell the difference $g_m$, $R_ds$ at DC and these at AC through inclusion of internal RF-choke. The results of the established model built up using SDD in HP-Eessof show good agreement to the S/W measured data in DC, small signal, and noise characteristic. This model can also be applied to various computer aided analysis, such as linear simulation, 1-tone harmonic balance simulation, and multi-tone harmonic balance simulation, so the LNA(Low Noise Amplifier), oscillator, and mixer design has been shown using this model library.

  • PDF

An Ultra Small Size Phase Locked Loop with a Signal Sensing Circuit (신호감지회로를 가진 극소형 위상고정루프)

  • Park, Kyung-Seok;Choi, Young-Shig
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.6
    • /
    • pp.479-486
    • /
    • 2021
  • In this paper, an ultra small phase locked loop (PLL) with a single capacitor loop filter has been proposed by adding a signal sensing circuit (SSC). In order to extremely reduce the size of the PLL, the passive element loop filter, which occupies the largest area, is designed with a very small single capacitor (2pF). The proposed PLL is designed to operate stably by the output of the internal negative feedback loop including the SSC acting as a negative feedback to the output of the single capacitor loop filter of the external negative feedback loop. The SSC that detects the PLL output signal change reduces the excess phase shift of the PLL output frequency by adjusting the capacitance charge of the loop filter. Although the proposed structure has a capacitor that is 1/78 smaller than that of the existing structure, the jitter size differs by about 10%. The PLL is designed using a 1.8V 180nm CMOS process and the Spice simulation results show that it works stably.

Improving Low Frequency Signal Reproduction in TV Audio (TV 스피커의 저주파수 신호 재생 개선)

  • Arora Manish;Oh Yoonhark;Kim SeoungHun;Lee Hyuckjae;Jang Seongcheol
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.275-278
    • /
    • 2004
  • In TV sound system, loudspeakers are subject to severe size constraints. The small size of the transducer affects the low frequency signal performance of the system. Bass signal performance contributes significantly to the user perceived sound quality and a good bass signal reproduction is essential. Increasing the sound energy in the bass signal range is an unviable solution since the gain required are exceedingly high and signal distortion occurs because of the speaker overload. Recently methods are being proposed to invoke low frequency illusion using psychoacoustic phenomena of the missing fundamental. This paper proposes a simple and effective signal processing method to create bass signal illusion in TV speakers using the missing fundamental effect, at a complexity of 12 MIPS on Motorola 56371 audio DSP.

  • PDF

ON THE BACKGROUND-SUBTRACTED INTENSITY (백그라운드 제거후 신호의 세기에 대하여)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2005
  • When we measure a source signal in the presence of a background rate that has been independently measured, the usual approach is to obtain an estimate of the background rate by observing an empty part of the sky, and an estimate of the source signal plus background rate by observing the region where a source signal is expected. The source signal rate is then estimated by subtracting the background rate from the source signal plus background rate. However, when the rates or their observation times are small, this procedure can lead to negative estimates of the source signal rate, even when it should produce a positive value. By applying the Bayesian approach, we solve the problem and prove that the most probable value of source signal rate is zero when the observed total count is smaller than the expected background counts. It is also shown that the results from the conventional method is consistent with the most probable value obtained from the Bayesian approach when the source signal is large or the observation time is long enough.

Parameter Estimation of Linear-FM with Modified sMLE for Radar Signal Active Cancelation Application

  • Choi, Seungkyu;Lee, Chungyong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.372-381
    • /
    • 2014
  • This study examined a radar signal active cancelation technique, which is a theoretical way of achieving stealth by employing a baseband process that involves sampling the incoming hostile radar signal, analyzing its characteristics, and generating countermeasure signals to cancel out the linear-FM signal of the hostile radar signal reflected from the airborne target. To successfully perform an active cancelation, the effects of errors in the countermeasure signal were first analyzed. To generate the countermeasure signal that requires very fast and accurate processing, the down-sampling technique with the suboptimal maximum likelihood estimation (sMLE) scheme was proposed to improve the speed of the estimation process while preserving the estimation accuracy. The simulation results showed that the proposed down-sampling technique using a 2048 FFT size yields substantial power reduction despite its small FFT size and exhibits similar performance to the sMLE scheme using the 32768 FFT size.

Method of Received Signal Generation for Pulse Radar (펄스 레이더 수신 신호 생성 기법)

  • Ha, Jong-Soo;Park, Gyu-Churl
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.652-659
    • /
    • 2009
  • To analyze and verify the performance of a pulse radar without the real target data, there is a need to make the simulated signal which is similar to the received signal of the real target. In this paper, a method of the received signal generation for the pulse radar is proposed to solve the above need. The user-made scenarios are used to model the fast and small target and the clutter data based on the ground environment. These data are transformed into the electric signal using the proposed method. The efficiency of the proposed method is proved by comparing the signal of a field test with the simulated signal.

A Basic Study on the signal Processing and Analysis of ECG (심전도 신호처리 및 분석에 관한 기초연구)

  • 정구영;권대규;유기호;이성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.294-294
    • /
    • 2000
  • In this paper, we would like to discuss the signal processing and the algorithm for ECG analysis. The ECG gives us information about the condition of the heart muscle, because myocardial abnormality or infarction is inscribed on the ECG during myocardial depolarization and repolarization. Analyzing the ECG signal, we can find heart disease, for example, arrhythmia and myocardial infarction, etc. Particularly, detecting arrhythmia is more important, because serious arrhythmia can take away the life from patients within ten minutes. The wavelet transform decomposes the ECG signal into high and low frequency component using wavelet function. Recomposing high frequency bands including QRS complex, we can detect QRS complex and eliminate the noise from the original ECG signal. To recognize the ECG signal pattern, we adopted the curve-fitting partially and statistical method. The ECG signal is divided into small parts based on QRS complex, and then, each part is approximated to the polynomials. Comparing the approximated ECG pattern with some kinds of heart disease ECG pattern, we can detect and classify the kind of heart disease.

  • PDF

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

An Array-Based Sensor for Seafood Freshness Assessment

  • Gonzalez-Martin, Anuncia;Lewis, Brian;Raducanu, Marius;Kim, Jin-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3084-3092
    • /
    • 2010
  • This paper describes the development of an automated, hand-held sensor for the fast assessment of seafood freshness. The sensor developed here combined: an array-based chemical sensor, composed of incrementally different conducting polymer elements deposited on a small chip; a highly sensitive, custom-made electronics for the detection of very small signal changes; precise temperature control of the sensor chamber; and an on-board microcontroller for data collection, storage, automation, and analysis. The instrument was used to successfully test seafood samples with different degree of freshness and spoilage. A linear relationship between microbiological count and e-Nose signal for three different fish fillet was developed. Once the linear relationship is included into the hand-held unit software, the e-Nose signal can be used for assessment of seafood freshness without performing the microbiological count technique.