• Title/Summary/Keyword: Small-Signal Parameters

Search Result 200, Processing Time 0.024 seconds

Design of Domestic Induction Cooker based on Optimal Operation Class-E Inverter with Parallel Load Network under Large-Signal Excitation

  • Charoenwiangnuea, Patipong;Ekkaravarodome, Chainarin;Boonyaroonate, Itsda;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.892-904
    • /
    • 2017
  • A design of a Class-E inverter with only one inductor and one capacitor is presented. It is operated at the optimal operation mode for domestic cooker. The design principle is based on the zero-voltage derivative switching (ZVDS) of the Class-E inverter with a parallel load network, which is a parallel resonant equivalent circuit. An induction load characterization is obtained from a large-signal excitation test bench, which is the key to an accurate design of the induction cooker system. Consequently, the proposed scheme provides a more systematic, simple, accurate, and feasible solution than the conventional quasi-resonant inverter analysis based on series load network methodology. The derivative of the switch voltage is zero at the turn-on transition, and its absolute value is relatively small at the turn-off transition. Switching losses and noise are reduced. The parameters of the ZVDS Class-E inverter for the domestic induction cooker must be selected properly, and details of the design of the components of this Class-E inverter need to be addressed. A 1,200 W prototype is designed and evaluated to verify the validation of the proposed topology.

Expression of Hypoxia-inducible Factor-$1{\alpha}$ in Non-small Cell Lung Cancer: Relationship to Prognosis and Tumor Biomarkers (비소세포 폐암에서 HIF-$1{\alpha}$의 발현: 예후 및 종양표지자와의 관련성)

  • Cho, Sung-Rae;Byun, Joung-Hun;Kim, Jong-In;Lee, Bong-Geun;Chun, Bong-Kwon
    • Journal of Chest Surgery
    • /
    • v.39 no.11 s.268
    • /
    • pp.828-837
    • /
    • 2006
  • Background: Tissue hypoxia is characteristic of many human malignant neoplasm, and hypoxia inducible factor-1(HIF-1) plays a pivotal role in essential adaptive response to hypoxia, and activates a signal pathway for the expression of the hypoxia-regulated genes, resulting in increasing $O_2$ delivery or facilitating metabolic adaptation to hypoxia. Increased level of HIF-$1{\alpha}$ has been reported in many human malignancies, but in non-small cell lung carcinoma the influence of HIF-$1{\alpha}$ on tumor biology, including neovascularization, is not still defined. In present study the relationship of HIF-$1{\alpha}$ expression on angiogenetic factors, relationship between the tumor proliferation and HIF-$1{\alpha}$ expression, interaction of HIF-$1{\alpha}$ expression and p53, and relationship between HIF-$1{\alpha}$ expression and clinico-pathological prognostic parameters were investigated. Material and Method: Archival tissue blocks recruited in this study were retrieved from fifty-nine patients with primary non-small cell lung carcinoma, who underwent pneumonectomy or lobectomy from 1997 to 1999. HIF-$1{\alpha}$, VEGF(vascular endothelial growth factor), and p53 protein expression and Ki-67 labeling index in tumor tissues were evaluated, using a standard avidin-biotin-peroxidase complex(ABC) immunohistochemistry. Relationship between the HIF-$1{\alpha}$ expression and VEGF, p53 overexpression and correlation between the HIF-$1{\alpha}$ expresseion and Ki-67 index were analyzed. Clinico-pathologic prognostic parameters were also analyzed. Result: HIF-$1{\alpha}$ expression in cancer cells was found in 24 of 59 cases of non-small cell lung carcinoma(40.7%). High HIF-$1{\alpha}$ expression was significantly associated with several pathological parameters, such as pathological TMN stage(p=0.004), pT stage(p=0.020), pN stage (p=0.029), and lymphovascular invasion(p=0.019). High HIF-$1{\alpha}$ expression was also significantly associated with VEGF immunoreactivity(p<0.001), and aberrant p53 expression(p=0.040). but was marginally associated with Ki-67 labeling index(p=0.092). The overall 5-year survival rate was 42.3%. The survival curve of patients with a high HIF-$1{\alpha}$ expression was worse than that of patients with low-expression(p=0.002). High HIF-$1{\alpha}$ expression was independent unfavorable factors with a marginal significance in multivariate analysis performed by Cox regression. Conclusion: It is suggested that high HIF-$1{\alpha}$ expression may be associated with intratumoral neovascularization possibly through HIF-VEGF pathway, and high HIF-$1{\alpha}$ expression could be associated with lymph node metastasis and post operative poor prognosis in patients with non-small cell lung carcinoma.

A Study on the Optimal Parameter Selection of a Power System Stabilizer for HVDC Linked System (HVDC 연계 시스템의 전력계통 안정화 장치의 적정 파라메터 선정에 관한 연구)

  • 김경철;최홍규;최병숙;강태은;고영곤
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.81-89
    • /
    • 2001
  • Power system stabilizer act efficiently to damp the electromechanical oscillations in interconnected power systems. This paper presents an algorithm for the optimal parameter selection of a power system stabilizer in two-area power systems with a series HVDC link. This method is one of the classical techniques by allocating properly pole-zero positions to fit as closely as desired the ideal phase lead between the voltage reference and the generator electrical power and by changing the gain to produce a necessary damping torque over the matched frequency range. The small signal stability and transient stability studies using the PSS parameters obtained from this method show that a natural oscillation frequency of the study case system is adequately damped. The simulation used in the paper was performed by the Power System Toolbox software program based on MATLAB.

  • PDF

Control of a Bidirectional Z-Source Inverter for Electric Vehicle Applications in Different Operation Modes

  • Ellabban, Omar;Mierlo, Joeri Van;Lataire, Philippe
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.120-131
    • /
    • 2011
  • This paper proposes two control strategies for the bidirectional Z-source inverters (BZSI) supplied by batteries for electric vehicle applications. The first control strategy utilizes the indirect field-oriented control (IFOC) method to control the induction motor speed. The proposed speed control strategy is able to control the motor speed from zero to the rated speed with the rated load torque in both motoring and regenerative braking modes. The IFOC is based on PWM voltage modulation with voltage decoupling compensation to insert the shoot-through state into the switching signals using the simple boost shoot-through control method. The parameters of the four PI controllers in the IFOC technique are designed based on the required dynamic specifications. The second control strategy uses a proportional plus resonance (PR) controller in the synchronous reference frame to control the AC current for connecting the BZSI to the grid during the battery charging/discharging mode. In both control strategies, a dual loop controller is proposed to control the capacitor voltage of the BZSI. This controller is designed based on a small signal model of the BZSI using a bode diagram. MATLAB simulations and experimental results verify the validity of the proposed control strategies during motoring, regenerative braking and grid connection operations.

Wavelet analysis and enhanced damage indicators

  • Lakshmanan, N.;Raghuprasad, B.K.;Muthumani, K.;Gopalakrishnan, N.;Basu, D.
    • Smart Structures and Systems
    • /
    • v.3 no.1
    • /
    • pp.23-49
    • /
    • 2007
  • Wavelet transforms are the emerging signal-processing tools for damage identification and time-frequency localization. A small perturbation in a static or dynamic displacement profile could be captured using multi-resolution technique of wavelet analysis. The paper presents the wavelet analysis of damaged linear structural elements using DB4 or BIOR6.8 family of wavelets. Starting with a localized reduction of EI at the mid-span of a simply supported beam, damage modeling is done for a typical steel and reinforced concrete beam element. Rotation and curvature mode shapes are found to be the improved indicators of damage and when these are coupled with wavelet analysis, a clear picture of damage singularity emerges. In the steel beam, the damage is modeled as a rotational spring and for an RC section, moment curvature relationship is used to compute the effective EI. Wavelet analysis is performed for these damage models for displacement, rotation and curvature mode shapes as well as static deformation profiles. It is shown that all the damage indicators like displacement, slope and curvature are magnified under higher modes. A localization scheme with arbitrary location of curvature nodes within a pseudo span is developed for steady state dynamic loads, such that curvature response and damages are maximized and the scheme is numerically tested and proved.

The Influence of the Number of Electrodes, the Position and Direction of a Single Dipole on the Relation Between S/N ratio and EEG Dipole Source Estimation Errors (뇌전위의 단일 쌍극자 모델에서 전극의 개수, 쌍극자의 위치 및 방향이 S/N과 쌍극자 추정 오차사이의 관계에 미치는 영향에 관한 시뮬레이션 연구)

  • 김동우;배병훈
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.71-76
    • /
    • 1994
  • In the source localization using single dipole model, the influence of the number of electrodes, the position and direction of a single dipole on the relation between S/W ratio and dipole parameter estimation errors is important. Monte Carlo simulation was used to investigate this influence. The forward problem was calculated using three spherical shell model, and dipole parameters were optimized by means of simplex method. As the number of electrodes became large, as the dipole went from midbrain to cortex, and as the direction of dipole changed from radial to tangential, the average and standard deviation of estimation errors became small.

  • PDF

Stability Analysis of Grid-Connected Inverters with an LCL Filter Considering Grid Impedance

  • Li, Xiao-Qiang;Wu, Xiao-Jie;Geng, Yi-Wen;Zhang, Qi
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.896-908
    • /
    • 2013
  • Under high grid impedance conditions, it is difficult to guarantee the stability of grid-connected inverters with an LCL filter designed based on ideal grid conditions. In this paper, the theoretical basis for output impedance calculation is introduced. Based on the small-signal model, the d-d channel closed-loop output impedance models adopting the converter-side current control method and the grid-side current control method are derived, respectively. Specifically, this paper shows how to simplify the stability analysis which is usually complemented based on the generalized Nyquist stability criterion (GNC). The stability of each current-controlled grid-connected system is analyzed via the proposed simplified method. Moreover, the influence of the LCL parameters on the stability margin of grid-connected inverter controlled with converter-side current is studied. It is shown that the stability of grid-connected systems is fully determined by the d-d channel output admittance of the grid-connected inverter and the inductive component of the grid impedance. Experimental results validate the proposed theoretical stability analysis.

A Performance Bound of Mu1ti-hop Mu1ti-Relay Wireless Communication Systems with Optimal Path Selection (다중-홉 다중-릴레이 무선 통신 시스템에서 최적 경로 선택 기법의 성능 한계)

  • Almuradov, Kamol;Park, Jin-Bae;Kim, Yun-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1C
    • /
    • pp.1-7
    • /
    • 2011
  • Recently, multi-hop relay transmission has drawn much attention owing to its advantage of coverage extension at low power consumption. In this paper, we derive a performance bound of multi-hop communication systems with multiple amplify-and-forward relays when the optimal path is selected. The bound is derived in generalized Nakagami fading channels with different parameters for each hop by applying the geometric mean bound to the path signal-to-noise ratio (SNR) and obtaining the moment generation function of the bound. It is shown that the bound based on the geometric mean is closer to the actual performance of optimal path selection when the fading effect is small.

A Comparison of MRS Data for SVS and 3D CSI in Human Brain Study (두경부 MRS검사의 SVS와 3D CSI 데이터의 비교 분석및 임상응용을 위한 연구)

  • Yoon, Seong-Ik;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.93-95
    • /
    • 2005
  • MRS is to measure very small metabolite signals, whose resonant frequencies spread over the chemical shift range characteristic of the measured nucleus. The MR signal originates from the excited volume, which is a column of tissue divided into slices by gradient or rf encoding. The parameters that acquired data affected by TE, TR, and other variables. The higher spatial resolution of 3D CSI compared to SVS and its ability to examine regional metabolite variations for brain study.

  • PDF

Power-Space Functions in High Speed Railway Wireless Communications

  • Dong, Yunquan;Zhang, Chenshuang;Fan, Pingyi;Fan, Pingzhi
    • Journal of Communications and Networks
    • /
    • v.17 no.3
    • /
    • pp.231-240
    • /
    • 2015
  • To facilitate the base station planning in high speed railway communication systems, it is necessary to consider the functional relationships between the base station transmit power and space parameters such as train velocity and cell radius. Since these functions are able to present some inherent system properties determined by its spatial topology, they will be referred to as the power-space functions in this paper. In light of the fact that the line-of-sight path persists the most power of the received signal of each passing train, this paper considers the average transmission rate and bounds on power-space functions based on the additive white Gaussian noise channel (AWGN) model. As shown by Monte Carlo simulations, using AWGN channel instead of Rician channel introduces very small approximation errors, but a tractable mathematical framework and insightful results. Particularly, lower bounds and upper bounds on the average transmission rate, as well as transmit power as functions of train velocity and cell radius are presented in this paper. It is also proved that to maintain a fixed amount of service or a fixed average transmission rate, the transmit power of a base station needs to be increased exponentially, if the train velocity or cell radius is increased, respectively.