• 제목/요약/키워드: Small size water treatment plant

검색결과 11건 처리시간 0.02초

기존수처리 공정 및 고도정수처리 공정에서 NOM의 분자크기 분포 변화 (Molecular Size Distributions of NOM in Conventional and Advanced Water Treatment Processes)

  • 최일환;정유진
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.682-689
    • /
    • 2008
  • The purpose of this study was to find out the variation between molecular size distribution (MSD) of natural organic matter (NOM) in raw waters after different water treatment processes like conventional process (coagulation, flocculation, filtration) followed by advanced oxidation process (ozonation, GAC adsorption). The MSD of NOM of Suji pilot plant were determined by Liquid Chromatography-Organic Carbon Detection (LC-OCD) which is a kine of high-performance size-exclusion chromatography (HPSEC) with nondispersive infrared (NDIR) detector and $UV_{254}$ detector. Five distinct fractions were generally separated from water samples with the Toyopearl HW-50S column, using 28 mmol phosphate buffer at pH 6.58 as an eluent. Large and intermediate humic fractions were the most dominant fractions in surface water. High molecular weight (HMW) matter was clearly easier to remove in coagulation and clarification than low molecular weight (LMW) matter. Water treatment processes removed the two largest fractions almost completely shifting the MSD towards smaller molecular size in DW. No more distinct variation of MSD was observed by ozone process after sand filtration but the SUVA value were obviously reduced during increase of the ozone doses. UVD results and HS-Diagram demonstrate that ozone induce not the variation of molecular size of humic substance but change the bond structure from aromatic rings or double bonds to single bond. Granular activated carbon (GAC) filtration removed 8~9% of organic compounds and showed better adsorption property for small MSD than large one.

휴게소 개인하수처리시설의 슬러지 탈수공정 적용에 통한 고도처리 개선 연구 (A Study on the Advanced Treatment Process Improvement through the Dewatering Application an Expressway Rest Area Individual Sewage Treatment Plant)

  • 최유현;주현종
    • 한국물환경학회지
    • /
    • 제33권1호
    • /
    • pp.63-69
    • /
    • 2017
  • Small size privately owned wastewater treatment plants have been difficult to treat their wasted sludge and maintain steady effluent quality compared with publicly owned wastewater treatment plants. Therefore, this study has focused on treatment efficiency enhancement, specially nitrogen removal efficiency by recycling dewatering filtrate as an alkalinity additive from filter press using $CaCO_3$. As the result, it was found that the optimal mixing ratio between the excess sludge and $CaCO_3$ was 1:2. The major operation parameters such as specific substrate utilization rate, specific nitrification rate, and specific denitrification rate were also improved 64% ($0.048-0.079mg\;BOD_5/mg\;MLVSS{\cdot}day$), 35% ($0.020-0.027mg\;NH_3-N/mg\;MLVSS{\cdot}day$) and 68% ($0.051-0.086mg\;NO_3{^-}-N/mg\;MLVSS{\cdot}day$), respectively, after the adoption of new methods. Therefore, both the problem of sludge treatment at small scale plants and the need for efficiency improvement could be solved.

스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구 (A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant)

  • 이지원;김유현;길경익
    • 한국습지학회지
    • /
    • 제24권1호
    • /
    • pp.38-43
    • /
    • 2022
  • 스마트(Smart) 하수처리장은 하수처리 전 과정에 대한 ICT 기반의 실시간 모니터링, 원격 제어 관리 및 지능화 체계를 구축하여 안전하고 깨끗한 물환경을 조성하는 것을 의미한다. 이러한 스마트 하수처리장의 핵심이 되는 기술이 계측기를 활용한 운전제어 기술이라 할 수 있다. 본 연구진은 국내에서 진행중인 하수처리장 지능화 연구사업들을 참고하여 지능화사업 구축 시 필요한 운전제어 기술들을 분석하고 제시하였다. 분석 결과 규모별 제어, 반류수 제어, 연계처리수 제어, 약품량 제어, 동절기 운영제어, 총 유기탄소 제어까지 총 6개의 제거 기술에 대해 제시하였다. 규모별로는 소규모와 중규모 대규모로 구분할 수 있는 기준을 제시하였고, 반류수 제어의 경우 반류수를 관리할 수 있는 수질 및 유량 센서의 위치를 제시하였다. 연계처리수 제어의 경우 연계처리수가 하수처리장에 미치는 영향과 제어 지점을 제시하였으며, 약품주입량 제어의 경우 지능형 하수처리장 도입에 따라 약품 주입량을 최적화할 수 있는 시스템을 제시하였다. 동절기 운영의 경우 수온 저하에 따른 질산화 저하를 고려하였을 때 제어해야 하는 센서와 펌프를 제시하였다. 총 유기탄소 제어의 경우 향후 오염총량제를 고려한 연동 시스템을 제시하였다. 이러한 운전제어 시나리오들은 향후 지능형 하수처리 알고리즘과 시나리오에 사용될 기초자료로 활용될 수 있을 것으로 판단된다.

입자계수기를 이용한 생물활성탄 공정의 효율평가 (Evaluation of Biological Activated Carbon Using Particle Counter)

  • 김희근;류동춘;김현실;류병순;문성용;김승현;김원경
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.823-828
    • /
    • 2006
  • For this study, an online particle counter was installed before and after the activated carbon filtration process of D water treatment plant where has advanced water treatment processes, produces average 900,000ton/day of drinking water and supply the produced drinking water to Busan citizens. We collected and analyzed particle count data for about 1 year. We inspected particle breakthrough in three out of sixteen filter processes operated at same conditions, i.e. 5th filter, 6th filter and 7th filter. According to the monitoring results, 6th and 7th filters showed similar results while 5th filter showed different results. When compared seasonal effect, the particle count for dry season was below 10 particles/ml while the particle count for August when monthly average rainfall is over 200mm was much higher than for dry season. In January and August, there was a difference in breakthrough particle size. In January, small particles in 2~3um were mainly detected while in August 10um particles were mainly detected and the size distribution was 40% of total count.

재정사업과 민간투자사업의 하수처리장 하수유입률 특성분석 (Comparing the Inflow Rate of Sewage Treatment Plants Invested by the Public Funds or Public-Private Partnership (PPP) Projects)

  • 이원석;조은주;손영규;김지형
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.778-784
    • /
    • 2009
  • The purpose of this study is to figure out the differences of the inflow rates of Sewage Treatment Plants (STP), invested by public fund or public-private partnership (PPP). This paper finds that the average ratio of sewage inflow according to facility capacities (medium and small scale STP) was either nearly below 30% or above 100% in the first year. As the size of STP increased, there was decrease in the accuracy of demand assumption. This was because the operation time when the ratio of sewage inflow was uniform was different according to the size of STP, whereby the time was short when the STP were small. The design average ratio of sewage inflow was 10% larger than the real average ratio; this was considered overdesigned. In the case of a plant built by the PPP scheme, the average ratio of inflow of the STP before an abolition of MRG was larger than after the abolition of MRG. This may be explained by moral hazard from too much reliance on MRG. After the abolition of MRG, the demand risk of PPP was shifted from a PPP project to a conventional project.

수용액상에서 부유 미립자의 표면전위와 응집특성에 관한 연구 (Studies on the surface charge and coagulation characteristics of suspended particles in the aqueous phase)

  • 박상원;김성국;홍대일
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.363-369
    • /
    • 1999
  • This study aimed to elucidate the relationship between theoretical parameters affecting the coagulation process and the real coagulation phenomenon applied to the dye wastewater. Emphasis was placed on the effective removal of the suspend particulates. Parameters studied in this study are pH, coagulant concentration and surface potential. Optimal dosages of coagulants by the measurement of the zeta potential at lower then $25^{\circ}C$ are 5\times$10^P-3}$ M of $FeCl_3 and 1.4\times10^{-6}M of Fe_2(SO_4)_3$. The results were well agreeded with the separate Jar-test results. Emphasis was also placed on the relationship between water quality and the content of SS. It was found that the COD and DOC were reduced to 65% and 85%, respectively. The turbidity at the above condition was reduced from 300 NTU to 0~1 NTU. Efforts were made to clarify the behavior of the suspend solid as affecting the water quality. 12,000~13,000 particles/10mL in $1~50\mu$m size range particulates in the raw wastewater were reduced to 300 particle/10mL in the same range after treatment. This research has proposed the methodology to find out the optimal condition of coagulation for small scale wastewater treatment plant or chemical coagulation process.

  • PDF

이온화가스와 응집공정을 조합한 축산폐수의 처리시 용존 유기물의 특성에 관한 연구 (Study of Soluble Organic Matter of Livestock Wastewater Treated by Ionized Gas and Coagulation after Ionized Gas)

  • 이은주;정팔진;김민정;현미희
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.708-713
    • /
    • 2004
  • This study was performed to investigate the variations of hydrophilic and hydrophobic organic matter fractions in soluble organic matter according to livestock wastewater treatment by ionized gas and coagulation effect to these fractions after ionized gas contact. As a result of experiment, because of ionized gas contact, particle in the surface of livestock wastewater was more smaller and the result was consisted of particle size analysis and the amount of small size was increased. Also, we confirmed that organic matters in livestock wastewater by ionized gas contact were removed. The relation equation between ionized gas contact time(X) and $TCOD_{cr}$(Y) was shown as yscale(y)=3.748-0.431* xscale(X). That between ionized gas contact time(X) and $TCOD_{cr}$(Y) was yscale(y)=3.283-0.463* xscale(X). As respects the HPL(hydrophilic matter)and HPO(hydrophobic matter) fractions of raw in livestock wastewater treatment plant, HPL fraction was 53.2% and HPO fraction was 46.8%. But, HPO fraction according to ionized gas treatment was increased at 30min and after that time, HPL fraction was increased. Also, when we performed coagulation process after ionized gas treatment of raw wastewater, the removal efficiency of organic matter was the highest at 30min of ionized gas treatment because of the variation of HPL and HPO fractions in organic matter by ionized gas. In coagulation process following after ionized gas process, HPO was removed more effective than HPL.

Design, setup and routine operation of a water treatment system for the monitoring of low activities of tritium in water

  • C.D.R. Azevedo ;A. Baeza ;E. Chauveau ;J.A. Corbacho ;J. Diaz;J. Domange;C. Marquet ;M. Martinez-Roig ;F. Piquemal ;C. Roldan;J. Vasco ;J.F.C.A. Veloso ;N. Yahlali
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2349-2355
    • /
    • 2023
  • In the TRITIUM project, an on-site monitoring system is being developed to measure tritium (3H) levels in water near nuclear power plants. The quite low-energy betas emitted by 3H have a very short average path in water (5 ㎛ as shown by simulations for 18 keV electrons). This path would be further reduced by impurities present in the water, resulting in a significant reduction of the detection efficiency. Therefore, one of the essential requirements of the project is the elimination of these impurities through a filtration process and the removal of salts in solution. This paper describes a water treatment system developed for the project that meets the following requirements: the water produced should be of near-pure water quality according to ISO 3696 grade 3 standard (conductivity < 10 µS/cm); the system should operate autonomously and be remotely monitored.

전자선과 불가사리 분말을 이용한 하수슬러지 탈수능 향상 (Enhancement of Sludge Dewaterability using a Starfish and the Radiation Technology)

  • 유대현;이재광;이면주
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.681-687
    • /
    • 2004
  • This study was focused on the manufacturing method of a dewatering aid, which would reduce the water content of the sludge cake by enhancing the dewaterability of sewage sludge. The pretreatment technology for sludge by using radiation and among diverse discarded resources were starfish selected as the material to manufacture the dewatering aid. Starfish went through the process of washing, drying, and pulverizing. The starfish powder made in this process was applied to the digested sludge generated at the sewage treatment plant of D City, and its effects were investigated. The starfish powder that was 300 ${\mu}m$ in particle size was added to the irradiated digested sludge. After the application of the condensation process, the sludge with the starfish powder added was dewatered using the belt press and centrifuge, which were the traditional pressure dewatering devices. As the result, it reduced the water content of the sludge 20% higher than the dewatered cake with no dewatering aid added and irradiation. When the powder was added, it contributed to less use of the coagulant added. The more irradiation dose, the lower water content did the dewatered cake have and the more coagulant was needed for condensation, which seems to be a disadvantage that can be compensated for by the starfish dewatering aid. A small-scaled treatment of the study to a radiation technology and dewatering aid using a discarded resource confirmed the potential of dewaterability. Based on the results saying that the dewatering aid and radiation technology can improve dewatering effects using the traditional dewatering devices, this pretreatment technology will be expected to be applied to sewage treatment plants.

Rockwool과 Phenolic Foam 배지에서 양액공급 방법이 프리카(Capsicum annuum) 'Veron'의 생육과 수량에 미치는 영향 (Irrigation Method of Nutrient Solution Affect Growth and Yield of Paprika 'Veyron' Grown in Rockwool and Phenolic Foam Slabs)

  • 김광수;이용범;황승재;정병룡;안철근
    • 원예과학기술지
    • /
    • 제31권2호
    • /
    • pp.179-185
    • /
    • 2013
  • 파프리카 수경재배용으로 사용되고 있는 암면을 대체하기 위해 개발 배지인 Phenolic foam(LC, Oasis Co.)의 물리특성에 맞는 양액공급방법을 구명하기 위해 양액공급 방법을 누적일사량 $100J{\cdot}cm^{-2}$에 주당 1회 공급량 100mL(100-100)를 대조구로 $90J{\cdot}cm^{-2}$에 주당 1회 공급량 90mL(90-90), $90J{\cdot}cm^{-2}$에 주당 1회 공급량 80mL(90-80) 등 3처리를 두고 Rockwool 배지와 함께 비교하였다. 양액공급 방법별 배액률은 100-100이 Rockwool에서 33.8%, LC에서 36.7%로 높았고 90-80이 Rockwool에서 30.4%, LC에서 33.7%로 낮았다. Rockwool 배지의 함수률과 EC는 63.6-68.9%, $4.4-5.dS{\cdot}m^{-1}$, LC 배지는 52.9-58.8%, $5.5-6.5dS{\cdot}m^{-1}$를 유지하였다. 100-100과 90-90 처리는 90-80 처리보다 생육이 촉진되어 과실이 크고 평균과중이 무거웠다. 착과수는 90-80 처리가 Rockwool 배지에서 주당 8.0개, LC 배지에서 8.3개로 가장 많았다. 상품과수는 90-90 처리가 가장 많았고 비상품 과수는 90-80 처리가 소과와 배꼽썩음과의 발생이 많아 주당 1.7-1.8개로 가장 많았다. 수량은 90-90 처리가 높았다.