• 제목/요약/키워드: Small cone

검색결과 225건 처리시간 0.027초

Palynological Study of Akindonuma Moor in the Central Oh-u Backbone Range, Northeasternl Japan

  • Park, Ji-Hoon
    • The Korean Journal of Ecology
    • /
    • 제25권1호
    • /
    • pp.45-49
    • /
    • 2002
  • Pollen analyses and $^{14}$ C dating of the sediments of the Akindonuma moor, which is situated in a closed depression of an old landslide, were peformed in order to study the vegetation history of the montane zone of the Miyagi Prefecture, Northeast Japan. The main results are as follows: Two forest zones have been distinguished: 1) the A-I zone, or the Fagus-Quercus-Betula forest (R I stage, before about 11,700 yrs B.P.), and 2) the A-II zone, or the Fagus-Quercus forest (R II stage, after about 11,700 yrs B.P.). By comparing the geological section with the pollen diagram of the moor, it is assumed that the deposit environment of the Middle Part, which mostly consists of peat layers, is very stable. During the period, the Ulmus/Zelfkova pollen ratio was very low and small peak was not recognized. According to the preceding research, theme is a close relationship between the fluctuation of the Ulmus/Zelkova pollen ratio and the general trend of hillslope instability in the changing balance of temporature and precipitation Actually, Zelkova serrata tends to cover the footslope and the lower sideslope. Ulmus davidiana covers the footslope and the alluvial cone. Therefore, the fact that the Ulmus/Zeikova pollen ratio was very low and small peak was not recognized, is believed to reflect the stability of the earth's surface environment, which was estimated from the geological section.

Determination of Diesel Sprays Characteristics in Real Engine In-Cylinder air Density and Pressure Conditions

  • Payri Raul;Salvador F. J.;Gimeno J;Soare V.
    • Journal of Mechanical Science and Technology
    • /
    • 제19권11호
    • /
    • pp.2040-2052
    • /
    • 2005
  • The present paper centers on the establishment of a quantified relationship between the macroscopic visual parameters of a Diesel spray and its most influential factors. The factors considered are the ambient gas density, as an external condition relative to the injection system, and nozzle hole diameter and injection pressure as internal ones. The main purpose of this work is to validate and extend the different correlations available in the literature to the present state of the Diesel engine, i.e. high injection pressure, small nozzle holes, severe cavitating conditions, etc. Five mono-orifice, axi-symmetrical nozzles with different diameters have been studied in two different test rigs from which one can reproduce solely the real engine in-cylinder air density, and the other, both the density and the pressure. A parametric study was carried out and it enabled the spray tip penetration to be expressed as a function of nozzle hole diameter, injection pressure and environment gas density. The temporal synchronization of the penetration and injection rate data revealed a possible explanation for the discontinuity observed as well by other authors in the spray's penetration law. The experimental results obtained from both test rigs have shown good agreement with the theoretical analysis. There have been observed small but consistent differences between the two test rigs regarding the spray penetration and cone angle, and thus an analysis of the possible causes for these differences has also been included.

직물형 유리섬유/에폭시 복합재료로 피막된 판유리의 미소강구 충격에 의한 표면파괴거동 (Surface Fracture Response of Glass Eabric/Epoxy Lamina-Bonded Glass Plates to Impact with a Small-Diameter Steel Ball)

  • 김형구;최낙삼
    • Composites Research
    • /
    • 제13권4호
    • /
    • pp.75-82
    • /
    • 2000
  • 유리섬유/에폭시 복합재료로 피막한 유리판의 표면파괴거동을 연구하기 위하여 미소강구 충격실험을 수행하였다. 본 연구에서는 다섯 종류의 재료, 단순소다유리판(soda-lime glass plates), 유리섬유/에폭시박막(glass/epoxy lamina)을 1층 접착, 비접착한 시편과 박막을 3층 접착, 비접착한 시편을 사용하였다. 충격속도 범위 40∼120m/s에서 유리판 배면에서의 최대 응력과 흡수파괴에너지를 측정하였다. 충격 속도증가에 따라 링균열, 콘균열, 레이디얼 균열이 시편 내부에서 발생하였다. 복합재료 박막으로 피막한 결과, 소다유리판의 균열은 현저히 감소하였으며 측정한 최대 응력과 흡수파괴에너지를 이용하여 표면 파괴거동 특성을 평가할 수 있었다.

  • PDF

Effects of the Micro-hole Target Structures on the Laser-driven Energetic Proton Generation

  • Pae, Ki-Hong;Choi, Il-Woo;Hahn, Sang-June;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.48-52
    • /
    • 2009
  • Micro-hole targets are studied to generate energetic protons from laser-thin foil targets by using 2-dimensional particle-in-cell simulations. By using a small hole, the maximum energy of the accelerated proton is increased to 4 times higher than that from a simple planar target. The main proton acceleration mechanism of the hole-targets is the electrostatic field created between the fast electrons accelerated by the laser pulse ponderomotive force combined with the vacuum heating and the target rear surface. But in this case, the proton angular distribution shows double-peak shape, which means poor collimation and low current density. By using a small cone-shaped hole, the maximum proton energy is increased 3 times higher than that from a simple planar target. Furthermore, the angular distribution of the accelerated protons shows good collimation.

Prediction of Tensile Strength of a Large Single Anchor Considering the Size Effect

  • Kim, Kang-Sik;An, Gyeong-Hee;Kim, Jin-Keun;Lee, Kwang-soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.201-207
    • /
    • 2019
  • An anchorage system is essential for most reinforced concrete structures to connect building components. Therefore, the prediction of strength of the anchor is very important issue for safety of the structures themselves as well as structural components. The prediction models in existing design codes are, however, not applicable for large anchors because they are based on the small size anchors with diameters under 50 mm. In this paper, new prediction models for strength of a single anchor, especially the tensile strength of a single anchor, is developed from the experimental results with consideration of size effect. Size effect in the existing models such as ACI or CCD method is based on the linear fracture mechanics which is very conservative way to consider the size effect. Therefore, new models are developed based on the nonlinear fracture mechanics rather than the linear fracture mechanics for more reasonable prediction. New models are proposed by the regression analysis of the experimental results and it can predict the tensile strength of both small and large anchors.

Practical Implementation of Patient-Specific Quality Assurance for Small and Multiple Brain Tumors in CyberKnife with Fixed Collimators

  • Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.53-58
    • /
    • 2018
  • This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.

고에너지 전자선 진자조사에 의한 선량분포 (The Dose Distribution of Arc therapy for High Energy Electron)

  • 추성실;김귀언;서창옥;박창윤
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF

Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

캡슐 하단부 구조변경에 따른 압력강하 및 진동특성 (Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures)

  • 최명환;주기남;조만순;김봉구
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1370-1377
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural integrity of the material capsule called 04M-17U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19.6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.