• Title/Summary/Keyword: Small chamber

Search Result 621, Processing Time 0.033 seconds

Characteristics of Volatile Organic Compounds Emitted in Building Materials and Their Predictions of Time-dependent Variation

  • Pang, Seung Ki;Sohn, Jang Yeul;Lee, Kwang Ho
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • Unlike other countries, Korea uses various kinds of wall-paper as finishing material. Conventional wall-paper consists of paper and vinyl, and petrochemical ink is used for the decoration of the surface. Adhesive is used to paste the wall with the wall-paper, which emit substantial amounts of VOCs and formaldehyde. In this study, VOCs characteristics emitted from specimens made of concrete, mortar, gypsum board and wall-paper were investigated using small chamber method. Moreover, concentration and emission factor of BTEX(Benzene, Toluene, Ethylbenzene, m,p,o-Xylene) and TVOC were investigated, and concentration and emission factor decay were estimated. As a result of the prediction, both time-dependent concentration decay and cumulative concentration can be converted into the logarithmic scale. Furthermore, prediction equations were developed from the experimental results under accurately controlled experimental conditions. Therefore, there may be difference if the estimated equations are directly applied to real buildings. Further research should be done on the generalization of the developed prediction equations.

Numerical Analysis of the Formation of New Impinging Spray in the Combustion System (디젤연소실에서 새로운 충돌분무 형성에 대한 수치적 고찰)

  • Ryoo, Sung-Mok;Cha, Keun-Jong;Kim, Duck-Jool;Park, Kweonha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1625-1634
    • /
    • 1998
  • The objective of this study is to establish geometric guidelines for design of impaction parts prepared for removing undesirable effects of fuel deposition on a wall in small direct-injection diesel engines. In order to get the guidelines a new wall geometry is introduced and assessed, which has a flat top and a slant edge. The size of the flat top and the angle of the slant edge are varied and tested in same chamber condition, then their effects on spray dispersions and drop sizes are discussed. The results show that the case of 3.0mm flat top and $60^{\circ}$ edge angle gives the best spray characteristics for a small combustion chamber in the test conditions chosen in this paper.

Development of Power Flow Boundary Element Method for 3-dimensional Multi-domain Noise Analysis (3차원 다영역 공간의 소음해석을 위한 파워흐름경계요소법 개발)

  • Kim, Jong-Do;Hong, Suk-Yoon;Song, Jee-Hun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.967-974
    • /
    • 2011
  • The direct and indirect PFBEM(power flow boundary element method) for the treatment of the 3 dimensional multi-domain problems are proposed to predict the acoustic energy density in medium to high frequency ranges. In the proposed method, the equation is derived in a matrix form by considering coupled relationships of the power flow at the interface of given domains. The proposed method can successfully obtain the analytical solutions for the problems of coupled cubes and the small-scale reverberant chamber. Then the experiment is carried out to obtain STL(sound transmission loss) by using small-scale reverberant chamber and the results are compared with analysis results.

Analysis of Decompression Control Characteristics of Pneumatic Pressure Control System Considering Heat Transfer Characteristics (열전달 특성을 고려한 공기압 압력제어계의 감압제어특성 해석)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.90-95
    • /
    • 2006
  • Pneumatic control systems have been mainly used as a high speed operating system. Therefore, state change of air in a control volume was assumed to be adiabatic change and, pneumatic control systems have been analyzed by using this assumption. Especially, when absolute value of pressure change in the control volume is small, there is a tendency to neglect effect of temperature change on pneumatic control system because temperature change owing to pressure change is small. In this study, an effect of temperature change of air on the decompression control process was analyzed by considering change of mass flow rate, and heat transfer characteristics between air in the chamber and the chamber wall. As a result, this study could confirm that a slight temperature change of the air in the pneumatic pressure control system can influence on the dynamic characteristics of pressure response, and pressure control performance.

  • PDF

Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery (Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정)

  • Chu Sung Sil;Suh Chang Ok;Loh John J.K.;Chung Sang Sup
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF

A Study of Dosimetric Characteristics of a Diamond Detector for Small Field Photon Beams (광자선 소조사면에 대한 다이아몬드 검출기의 선량특성에 관한 연구)

  • Loh, John-K.;Park, Sung-Y.;Shin, Dong-O.;Kwon, Soo-I.;Lee, Kil-D.;Kim, Woo-C.;Cho, Young-K.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.195-203
    • /
    • 1999
  • It is difficult to determine dosimetric characteristics for small field photon beams since such small fields do not achieve complete lateral electronic equilibrium and have steep dose gradients. Dosimetric characteristics of small field 4, 6, and 10 MeV photon beams have been measured in water with a diamond detector and compared to measurements using small volume cylindrical and plane parallel ionization chambers. Percent depth dose (PDD) and beam profiles for 6 and 10 MeV photon beams were measured with diamond detector and cylindrical ion chamber for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. Total scatter factors($S_{c,p}$) for 4, 6, and 10 MeV photon beams were measured with diamond detector, cylindrical and plane parallel ion chambers for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. The $S_{c,p}$ factors obtained with three detectors for 4, 6, and 10 MeV photon beams agreed well ($\pm1.2%$) for field sizes greater than $2{\times}2,\;2.5{\times}2.5,\;and\;3{\times}3\;cm^2$, respectively. For smaller field sizes, the cylindrical and plane parallel ionization chambers measure a smaller $S_{c,p}$ factor, as a result of the steep dose gradients across their sensitive volumes. The PDD values obtained with diamond detector and cylindrical ionization chamber for 6 and 10MeV photon beams agreed well ($\pm1.5%$) for field sizes greater than $4{\times}4\;cm^2$. For smaller field sizes, diamond detector produced a depth-dose curve which had a significantly shallower falloff than that obtained from the measurements of relative depth-dose with a cylindrical ionization chamber. For the measurements of beam profiles, a distortion in terms of broadened penumbra was observed with a cylindrical ionization chamber since diamond detector exhibited higher spatial resolution. The diamond detector with small sensitive volume, near water equivalent, and high spatial resolution is suitable detector compared to ionization chambers for the measurements of small field photon beams.

  • PDF

Evaluation of the Thermal Properties of Disposable Coveralls for Railroad Carriage Maintenance Workers (철도 차량 정비 작업자를 위한 일회용 부직포 작업복의 온열적 성능 평가)

  • 최정화;이주영;김소영
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.8
    • /
    • pp.1175-1185
    • /
    • 2004
  • This study evaluated thermo-physiological and subjective properties of improved disposable coveralls for railroad carriage maintenance through climatic chamber trials and a filed study. Subjects wore five kinds of disposable coveralls (Type A: a disposable coverall on the market, Type B: a coverall with an improved hood and size-adjustable design, Type C: a coverall with a portable hood, Type D: a coverall with small holes for ventilation, Type E: a sleeveless coverall, Type F: a separated type of coverall with half sleeves) The air temperature in the climatic chamber was set in 9$^{\circ}C$ and 30$^{\circ}C$ For each condition, subjects simulated the railroad work for 120min. and rectal temperature, skin temperatures, clothing microclimate and subjective sensations were measured. The results of chamber trials showed rectal temperature and clothing microclimate did not display significant differences by clothing type. In 30$^{\circ}C$ air temperature, mean skin temperature was higher in Type E and Type F than in Type A(p<0.05) but between the improved coveralls(B-F), we could not find any significant difference. In the case of thermal comfort, the most preferred types were Type B and Type C in 9$^{\circ}C$ and Type F in 30$^{\circ}C$. All subjects felt more comfortable in the improved coveralls than in coveralls of the market (Type A). In field study, workers preferred Type B, Type C and Type F to Type A but the most favorite type differed by the specific type of work. Especially, workers were dissatisfied that Type D tore easily due to lots of small holes around the armpits and Type I did not protect workers' shoulder and arms from oil contamination. According to the climatic chamber trials and field study, the most effective coveralls were Type B and Type C for winter and Type F for summer.

Stem Effect Correction Factor of Ionization Chamber in Exposure Measurements of High Energy Photons (고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수)

  • Park, Cheol-Woo;Lee, Jae-Seung;Kweon, Dae-Chel;Cha, Dong-Soo;Kim, Jin-Soo;Kim, Kyoung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.

  • PDF

A Preliminary PAM Measurement of Ambient Air at Gosan, Jeju to Study the Secondary Aerosol Forming Potential (이차 에어러솔 생성 잠재력 평가를 위한 Potential Aerosol Mass (PAM) 챔버의 제주도 고산 대기분석 적용)

  • Kang, Eun-Ha;Brune, William H.;Kim, Sang-Woo;Yoon, Soon-Chang;Jung, Mu-Hyun;Lee, Mee-Hye
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.534-544
    • /
    • 2011
  • The secondary aerosol forming potential of ambient air was first measured with the Potential Aerosol Mass(PAM) chamber at Gosan supersite on Jeju island from October 22 to November 5, 2010. PAM chamber is a small flowthrough photo-oxidation chamber with extremely high OH and $O_3$ levels. The OH exposure in the PAM chamber was $(2{\pm}0.4){\times}10^{11}{\sim}(6{\pm}1.2){\times}10^{11}$ molecules $cm^{-3}$ s and was similar to 2 to 5 days of aging in the atmosphere. By periodically turning on and off UV lamps in the PAM chamber, ambient aerosol and newly formed aerosol (e.g. called as PAM aerosol) was alternately measured. Aerosol number and mass concentration in the range of 10~487 nm in diameter was measured by SMPS 3034. With UV lamps on, the nucleation mode particles smaller than 50 nm in diameters were formed. Their number concentration was greater than 105 $cm^{-3}$, leading to increase in aerosol mass by 0~8 ${\mu}gm^{-3}$. The variations of PAM and ambient aerosols were greatly dependent on characteristics of air masses such as precursor concentrations and degree of aging. This preliminary results suggests that PAM chamber is useful to assess the aerosol formation potential of air mass and its impact on the air quality. The further analysis of data with gaseous and particulate measurements will be done.