• Title/Summary/Keyword: Small chamber

Search Result 620, Processing Time 0.025 seconds

Study on Pullout Behavior and Determination of Ultimate Uplift Capacity of Pile Driven in Small Pressured Chamber (소형 압력 토조내에 타입된 말뚝의 인발 거동과 극한 인발 지지력 결정에 관한 연구)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.11 no.2
    • /
    • pp.19-28
    • /
    • 1995
  • Based on the various test data acquired in the field, the large pressure chamber and the small pressure chamber, uplift behaviors and method of determining the ultimate uplift capacity of pile driven in small pressure chamber were studied. After uplift pile experienced 2 or 3 sudden slip due to increase of uplift load, complete pullout failure was occurred. Thus, it appears that the ultimate uplift capacity could be identified as the load at displacement where first slip occurs. The ultimate uplift capacity might be determined in every test and the disturbance after first uplift test could be recovered by adding one blow of the drop hammer, which had to depend on the model pile capacity.

  • PDF

STABILITY OF A ROTATING BALL

  • Bykov, V.;Dementiev, O.
    • Journal of applied mathematics & informatics
    • /
    • v.9 no.1
    • /
    • pp.277-288
    • /
    • 2002
  • Influence of form errors of a chamber filled with a liquid on the movement and stability of a ball, rotating in the chamber, is studied. Two cases of the influence of the chamber form errors on the forces, acting on the ball, are defined. The first case describes the situation when limitations on the rotor shift are not imposed and disturbances of the chamber form are set by spherical harmonics not above the first order. In the second case disturbance of a chamber form is arbitrary and the rotor is supposed small. A rising here diflective moment tends to direct the angular speed vector along the small semiaxis of the ellipsoid, i.e., a stable position of the rotor appears.

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber (소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가)

  • Lee, Suk-Jo;Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.344-354
    • /
    • 2005
  • This study was carried out to evaluate the performance of a small chamber sampling and analytical method for the measurement of total volatile organic compounds (TVOC) and formaldehyde (HCHO) emission from building materials. While VOC was determined by the adsorbent tube sampling and sequential thermal desorption coupled with GC/MSD analysis, formaldehyde sampled with DNPH-silica cartridge was analyzed by HPLC. Wide-range performance criteria such as repeatability, desorption efficiency, emission chamber recovery test, duplicate precision, breakthrough volume and method detection limits were investigated for the evaluation of small chamber method. The overall precision of the small chamber sampling and analytical methods was estimated within 20~30% for target compounds. In conclusion, this study demonstrated that the small chamber sampling and analytical method can be reliably applied for the measurement of building materials pollutants.

A Study on the Emission Characteristics of Gaseous Organic Contaminants from Building Materials and Newly Constructed Apartments (신축 공동주택 및 건축자재에서의 오염물질 방출 특성)

  • Kim Yun-Deok;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.563-570
    • /
    • 2006
  • We investigated the emission characteristics of gaseous organic contaminants from building materials and newly constructed apartments. The emission test for building materials was done with small chamber method, and field measurements in newly constructed apartment were carried out by Korea Standard Test Method for Indoor Air Quality. First, the emission test by small chamber showed that the TVOC emission from building materials was much higher than formaldehyde. On the other hand, as expected, considerably high concentration of both TVOC and HCHO was detected in the new apartment.

Thermal analysis inside a small chamber including radiation (미소 챔버 내 복사열전달을 수반한 열유동 해석)

  • Lee, Hyung-Sik;Do, Gi-Jung;Lee, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.194-198
    • /
    • 2006
  • In this study, numerical modeling was performed to analyze air flow including radiation heat transfer inside a small chamber. Characteristics of heat transfer between source plate and target through glass are investigated for various surface temperature of heat source plate with buoyancy effect due to gravity force. Conduction heat transfer through the glass is considered and heat source plate is assumed to be a black body. Target surface temperature is largely affected by the radiation heat transfer. It can also be seen that as the source temperature increases target surface is dominated by radiation rather than convective heat transfer by air.

  • PDF

Effects of Natural Convection Cells on Temperature Uniformity in Hot Plate Chamber for Wafer Baking Process (반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면 온도 균일도에 미치는 영향)

  • Park, Jun-Su;Kwon, Hyun-Goo;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2512-2517
    • /
    • 2007
  • Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220mm and maintains temperature at $150^{\circ}C$. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity $1.2^{\circ}C$ when developing weak and small flow cells.

  • PDF

Measurement of Dose Distribution in Small Fields of NEC LINAC 6 MVX Using Films and Tissue Equivalent Phantoms (필름 및 tissue equivalent 팬톰을 이용한 NEC LINAC 6 MVX 소조사면에 대한 선량분포 측정)

  • Suh, Tae-Suk;Park, Dong-Rak;Choe, Bo-Young;Yoon, Sei-Chul;Jang, Hong-Seok;Park, Il-Bong;Kim, Moon-Chan;Bahk, Yong-Whee;Shin, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.9-17
    • /
    • 1993
  • The purpose of this paper is to develop a simple system to measure dose distribution in small fields of NEC LINAC 6 MVX using film and solid water instead of ion chamber and water phantom. Specific quantities measured include percent depth dose (PDD), off-axis ratio (OAR). We produced square fields of 1 to 3cm in perimeter in 1cm steps measured at SAD of 80cm. The PDD and OAR measured by film was compared with measurement made with ion chamber. We calculated the TMR from the basic PDD data using the conversion formula. The trends of our measured beam data and philips LINAC are similar each other. The measurement for the small field using film and solid water was simple. Hand-made film phantom was especially useful to measure OARs for the stereotactic radiosurgery.

  • PDF

Effects on Diesel Spray for Variation of Ambient Pressure and Impingement Land Position (주위 압력 및 충돌면 위치 변화가 디젤분무에 미치는 영향)

  • 박대순;김문헌;박권하
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.95-105
    • /
    • 1997
  • A diesel engine has become smaller and higher, thus sprays injected in high speed may be impinged on a small combustion chamber wall if there is not enough strong swirl. Those combustion chambers should have proper measures to avoid the spray impinged and deposited on a wall. One of the measures is a chamber prepared impingement parts raised on a chamber wall surface. In this system a spray is injected into the raised pip, broken into a number of smaller drops and spreaded out away from the wall surface. Therefore the fuel droplets distributes over inside of the combustion chamber. In this study, the positions, sizes and angles of the raised land are discussed to help the chamber design using spray wall impaction. The characteristics of the spray impinged on various lands are investigated and compared with each other. Then chamber shapes are discussed with the spray characteristics and the proper positions and size are proposed in some chamber volumes.

  • PDF

GENERATION OF p-DINITROBENZENE ATMOSPHERE AND METHEMOGLOBIN FORMATION IN RATS

  • Kim, Young-Chul
    • Toxicological Research
    • /
    • v.5 no.2
    • /
    • pp.97-104
    • /
    • 1989
  • A new exposure system was developed to generate p-dinitrobenzene (p-DNB) containing atmosphere. A glass column was filled with small glass beads coated with the chemical. The p-DNB containing medium was heated to a temperature beyond the boiling point of p-DNB. A stream of air flow was forced to pass through the column and let it mixed with fresh air before introducing into an inhalation chamber. The concentration of p-DNB in the chamber air was measured by direct assaying the air directly and by sampling the chemical using a microfilter installed in the chamber.

  • PDF