영구자석 동기발전기의 설계 및 시제품 특성 분석에 관한 연구 (A Study on Design and Performance Analysis of a Prototype Permanent Magnet Synchronous Generator)

  • 오진훈
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.75-80
    • /
    • 2014
  • The small wind turbines has the merits of setting up with low costs by individuals, and get the energy saving effects that, it has the secured, separate markets from the big range systems, and the developing of it is continuously proceeding. The objective of this paper is to provide the design characteristics analysis of a permanent magnet synchronous generator(PMSG) skewed for magnet of rotor, the main advantage to be explored with the use of a split core design is the reduction in manufacturing costs and its simplicity in manufacture, compared to the manufacturing costs of a core skew PM machine. This thesis is aiming mainly analyzing the characteristics of the prototype to verify through Finite Element Method(FEM) and tests.

풍력발전을 위한 소용량 영구자석형 동기발전기의 설계 및 해석 (Design and Analysis of Direct-Coupled, Small-Scaled Permanent Magnet Generator for Wind Power Application)

  • 김일중;최장영
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.39-51
    • /
    • 2014
  • This paper deals with design of a direct-coupled, small-scaled permanent magnet generator (PMG) for wind power application. First, this paper determines rated power and speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit including slot opening, teeth width and yoke thickness is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot considering winding packing factor. Finally, finite element (FE) method is employed in analyzing the details of the designed PMG and, test results such as back-emf measurements are given to confirm the design.

SRD를 이용한 UWB 기술용 단일/멀티밴드 Impulse Generator의 설계 (Design of Single/Multiband Impulse Generator Using SRD for UWB(Ultra Wideband) Technique)

  • 김기남;김인석
    • 한국항행학회논문지
    • /
    • 제9권1호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 논문에서는 차세대 근거리 실내 무선 환경 기술로 채택 가능성이 높은 UWB(Ultra Wideband)기술용 Impulse Generator를 SRD(Step Recovery Diode)를 이용하여 설계하였다. 설계 목표는 단순한 설계 구조와 함께 저가, 소형, 고성능의 Impulse Generator 개발에 있다. 미국의 FCC(Federal Communications Commission)의 기준인 주파수 범위 3.1~10.6 GHz, 출력 제한 레벨 -41.25 dBm을 만족하는 Impulse Generator를 회로 시뮬레이터인 Agilent Technologies사의 ADS를 이용하여 설계, 제작, 측정하였다. 설계된 회로의 출력 신호는 단일밴드용과 멀티밴드용으로 구분하였다.

  • PDF

직류자여자분권발전기의 최적선형전압조정기에 관한 연구 (On the Optimum Linear Voltage Regulator of a Self-excited DC Shunt Generator)

  • 원종수
    • 전기의세계
    • /
    • 제22권4호
    • /
    • pp.11-16
    • /
    • 1973
  • This paper presents an optimum control of the field resistance for the self-excited DC shunt generator to keep a constant terminal voltage in case of the load change or the torque variation in the system. The non-linearity of the system is linearized by applying the small signal technique and the linearized equation is solved by the maximum principle with the digital computer. The optimal control value of the field resistance for the step error of the generator output voltage is obtained and the transient voltage characteristics in the system are investigated.

  • PDF

Permanent Magnet Excited Generator For Gearless Wind Generation Plant

  • Curiac, Paul;Kang, D.H.;Park, D.Y.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.455-458
    • /
    • 2001
  • This paper presents an axial flux permanent magnet synchronous generator with a high power-to-weight ratio, dedicated for small-scale gearless wind power generation plants. For this purpose, a specific design is necessary to meet the imposed requirements. In this paper the design technique for the specifications is presented. The aim of the paper is also to discuss some of the first obtained test results and the involved demagnetizing problem (i.e. short-circuit).

  • PDF

풍력용 동기발전기의 전기자 반작용을 이용한 전기 제동방식에 관한 연구 (A study on electronic braking system using wind power synchronous generator's armature reaction)

  • 박귀열;문채주;정의헌;장영학;김의선
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.1-8
    • /
    • 2010
  • The mechanical parts of small windp ower generator less than 10kW are manufactured in the form of removing most of the accelerators. The braking system to protect blade from damages caused by high wind speed is manufactured in a manner having apparatus system(furling), manual brake or no brake. This study is on braking system in small size wind power generator, and carried out survey as following steps by applying electric braking system which uses armature reaction. We explained the principle of electric braking system and the principle of existing braking system. Also, this paper interpreted short circuit current through open circuit and short circuit, as well as checking brake system's action using armature reaction with real construction of control device.

소형 독립형 풍력발전기의 진동 모니터링 및 출력 성능 평가 (Vibration Monitoring and Power Performance Evaluation of a Small Stand-alone Wind Turbine Generator)

  • 유능수;김윤호;김석현
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.114-120
    • /
    • 2007
  • Vibration performance of a 6 kW stand-alone wind turbine(W/T) generator is investigated under the wind environment of Daegwanryung mountain area. In the W/T, wind condition, power performance and structural stability are correlated each other An integrated monitoring system which consists of accelerometers, anemometers, power meters and auxiliary sensors for atmospheric data are constructed to measure the required data simultaneously. Based upon the data acquired over a long period of time, vibration performance of the W/T structure is estimated with annual wind data and generating power performance. Within the operating speed range, possibility of severe nitration is diagnosed. Vibration sources are identified and countermeasures are proposed. The goal of the study is to offer the basic information on W/T vibration performance at the design stage of a small stand alone W/T structure.

Steam generator performance improvements for integral small modular reactors

  • Ilyas, Muhammad;Aydogan, Fatih
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1669-1679
    • /
    • 2017
  • Background: Steam generator (SG) is one of the significant components in the nuclear steam supply system. A variety of SGs have been designed and used in nuclear reactor systems. Every SG has advantages and disadvantages. A brief account of some of the existing SG designs is presented in this study. A high surface to volume ratio of a SG is required in small modular reactors to occupy the least space. In this paper, performance improvement for SGs of integral small modular reactor is proposed. Aims/Methods: For this purpose, cross-grooved microfins have been incorporated on the inner surface of the helical tube to enhance heat transfer. The primary objective of this work is to investigate thermal-hydraulic behavior of the proposed improvements through modeling in RELAP5-3D. Results and Conclusions: The results are compared with helical-coiled SGs being used in IRIS (International Reactor Innovative and Secure). The results show that the tube length reduces up to 11.56% keeping thermal and hydraulic conditions fixed. In the case of fixed size, the steam outlet temperature increases from 590.1 K to 597.0 K and the capability of power transfer from primary to secondary also increases. However, these advantages are associated with some extra pressure drop, which has to be compensated.

소형 밀리미터파 추적 레이다용 모의신호 발생장치 개발 (Development of Simulated signal generator for Small Millimeter-wave Tracking Radar)

  • 김홍락;박승욱;우선걸;김윤진
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.157-163
    • /
    • 2019
  • 대함용 소형 밀리미터파 추적 레이다는 저속으로 기동 중인 큰 RCS를 갖는 바다위의 함정 표적에 대하여 TWS(Track While Scan) 방식을 통하여 실시간으로 표적을 탐색, 탐지 하여 추적하는 펄스 방식의 레이더이다. 본 논문에서는 소형 밀리미터파 추적 레이다의 성능을 실험실 무반향 챔버 환경에서 확인하기 위한 모의신호 발생장치 개발에 대하여 서술한다. 추적 레이다용 모의신호를 생성하기 위한 요구사항과 요구사항을 충족하기 위한 모의신호 발생장치의 하드웨어 구성과 추적 레이다와 연동하여 시험을 하고 성능을 분석하기 위한 GUI 프로그램을 기술하고 성능시험을 통해 구현한 모의신호 발생장치를 검증하였다.

복합발전 풍력-디젤 하이브리드 시스템 설치 지역의 전력품질 분석 (Power Quality Analysis of Wind-Diesel Hybrid Generation System Installation Area)

  • 안해준;김현구;김석우;고석환;장길수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.539-541
    • /
    • 2009
  • A severely cold weather condition of King Sejong Station, Antarctica becomes a very severe condition for an installation/operation of wind generation system. When the existing wind generation system works, it may cause a damage and destruction of wind generation system and can bring about big problems in terms of the power quality. Accordingly, it is essential to obtain technologies for the installation and operation of small wind generation system for the polar region's wind generation, and to assess and demonstrate the performance in the severely-cold environment and the polar wind generation system's development, supplementation, alteration. Also, as the available power of King Sejong Station, Antarctica, the diesel generator has been mainly used, and the wind generator has been used in the hybrid form. Wind generation and diesel generation has the different load following control each other. In the wind generation, the generated power very rapidly changes according to the change of the velocity of the wind. On the other hand, the diesel generation shows very gentle change in the velocity of output. Therefore, the study is intended to analyze the 10kw small wind generator-diesel generator's power quality of King Sejong Station, Antarctica, which is the hybrid system installation area.

  • PDF