• 제목/요약/키워드: Small Generator

검색결과 691건 처리시간 0.037초

소형풍력발전 시스템용 축방향 자속형 영구자석 동기발전기의 특성해석과 실험 (Characteristic analysis and experiment of axial flux type permanent magnet synchronous generator for small wind turbine)

  • 유용민;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.704_705
    • /
    • 2009
  • This paper presents a axial flux permanent magnet synchronous generator(AFPMSG), which is suitable for both vertical-axis and horizontal-axis wind turbine generation system. The design and construction features of the AFPMSG are reviewed. The characteristic analysis is performed such as cogging torque and e.m.f waveform, with the aid of a 3D finite element method. The experimental results confirm the characteristic analysis developed.

  • PDF

부하변동에 따른 발전기 특성해석 (Characteristics Analysis of Generator by Load Variation)

  • 김종겸
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.507-510
    • /
    • 2006
  • 본 논문은 신재생에너지의 한 분야로서 청정에너지인 소수력 발전시스템 운영시 수용가 부하의 변동에 따른 발전기의 특성변화를 해석한 것이다. 모의에 사용된 동기발전기-전동기가 부하의 변동에 따라 토크, 속도, 전류 등이 어떤 영향을 받는지 전자계 과도해석 프로그램을 사용하여 나타내었다.

  • PDF

온톨로지 기반 보편적 DTD생성기의 구현 (Implementation of Universal DTD Generator based on Ontology)

  • 공용해;이경수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(3)
    • /
    • pp.71-74
    • /
    • 2002
  • XML is widely used to provide information on the web. Since accessing XML documents depends on their structures, it is difficult to extract necessary information from documents having different structures. We constructed an ontology of a small application domain and implemented an universal DTD generator from the ontology. The universal DTD can be used in extracting necessary information from the various XML document types representing an identical idea.

  • PDF

계통 운전조건에 따른 축 비틀림 전동 미소신호안정도 해석 (Analysis of Small Signal Stability for SSR on Generator Loading Condition)

  • 김동준;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.85-87
    • /
    • 2002
  • The paper describes the formulation of state matrix equations from the linearized multi-machine power system including network dynamics and the application of IEEE First Benchmark Model. The eigenvalues of IEEE First Benchmark Model are investigated not only by changing the compensation of series capacitance at no-load conditions, but also by varying the generator loading at fixed compensation of capacitance. In addition, the pure electrical self-excited mode is also examined by an eigen analysis and time domain simulation.

  • PDF

증기발생기 전열관에서의 응력부식균열 성장해석 (Simulation of Stress Corrosion Crack Growth in Steam Generator Tubes)

  • 신규인;박재학;김흥덕;정한섭
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.57-65
    • /
    • 2000
  • The stress corrosion crack growth is simulated assuming a small axial surface crack inside a S/G tube. Internal pressure and residual stresses are considered as applied forces. Stress intensity factors along crack front, variation of crack shape and crack growth rate are obtained and discussed. It is noted that the aspect ratio of the crack is not depend on the initial crack shape but depend on the residual stress distribution.

  • PDF

135MVA 수력 발전기의 전력 시스템 안정화 장치 적용 효과 분석 (An Analysis of Power System Stability(PSS) Effect with 135MVA Hydro Generator)

  • 옥연호;이은웅;변일환;오석영
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1100-1104
    • /
    • 2009
  • As national power consumption every year increases, the power plant which is in the process of planning tries to establish high-capacity generator. The power system tends to become a large size. With the progress of electronic components, the control systems of the generator have been digitalized and rapid-response control system is possible. However, the minute frequency vibration of grid occurred with the effect of rapid-response control system. To solve these problem, PPS(Power System Stability) has been introduced since 2004, and it has being installed and applied to the thermal and nuclear power plant which are high-capacity, over 800MVA. However the minute frequency vibration is gradually changed to the bigger frequency vibration by fast-action control system, and this regional frequency fluctuation might be diffused wide area. Therefore, it is applied to the hydro generator which is small with fast-action governor system, and it is necessary to control the minute frequency vibration to prevent to diffuse. In this paper, the effect will be proved by establishing PSS on the Hydro-Generator which has both digital excitation and governor system for the first time in Korea.

탄성지지된 엔진, 고정지지된 발전기 및 탄성 커플링으로 구성된 발전기 세트의 엔진 본체 진동 특성에 관한 사례 연구 (A Case Study on the Engine Body Vibration Characteristics of Generator Set consists of Engine-resilient-mounted, Generator-rigid-mounted and Flexible-coupling)

  • 김효정;김상환;이돈출
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.443-446
    • /
    • 2014
  • Recently the demand for natural gas as clean and safe energy due to concerns about global warming and interests in green ship is increasing. The dual fuel(DF) engine, one of environmentally friendly engines, is preferred for general merchant ships and power plants as well as LNG carriers. This is for the reasons of having higher efficiency and lower nitrogen and sulfur oxides emissions by operating on LNG fuel with a small amount of light fuel oil. In this study, the engine body vibration characteristics of 12V50DF in a generator set with engine-resilient-mounted, generator-rigid-mounted and flexible-coupling configuration are investigated through theoretical analysis and comprehensive vibration measurement. This analysis showed the dynamic behavior of engine excitation forces and seismic waves. And the suitable countermeasures for reducing vibration and safe operation are proposed.

  • PDF

Crowbar 장치를 이용한 최초 단시간뇌격전류 발생기술 및 뇌격전류발생기 개발 (Development of Lightning Current Generator and Technology for Generating the First Short Stroke Lightning Current Using a Crowbar Device)

  • 엄주홍;이태형;권기량;조성철
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.93-100
    • /
    • 2011
  • This paper presents a technical study for the first short stroke lightning current generator using a crowbar device. The so-called crowbar-technology is most common to make 10/350[${\mu}s$] impulse currents with high amplitude, and the lightning current generator with crowbar device has an economic advantage than the nominal RLC current generator. But both the operating efficiency and the operating reliability of crowbar spark gap are very important to design the current generator. So, the peaking circuit which consists of small capacitors and a spark gap is applied. And the multi-step coil for controlling the circuit constant at the different test conditions is used. The presented test facility is designed to perform impulse tests with amplitudes up to 50[kA] of 10/350[${\mu}s$].

한국표준형 원전 제어봉구동장치 전원공급계통의 전동발전기 세트 안정성 개선 (Improving Stability of Motor Generator Set of the Power Supply System for CEDM in Korean Standard Nuclear Power Plants)

  • 최일영;김진원
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.49-55
    • /
    • 2016
  • This paper analyzed a root cause of abnormality in the temperature and vibration at generator-side bearing of motor generator set (MG Set), which is a power supply system to control element drive mechanism (CEDM) of nuclear power plants (NPPs), and modified the design of roller-type and sealing method to improve the abnormalities. From the inspection of MG Set and analysis of temperature variation during service, it was found that the abnormal temperature transition was basically associated with original design of generator-side bearing, whose roller was axially restrained by inner race, and that the abnormal vibration level was caused by inserting small chips of cage and V-ring, which were generated due to the abnormal temperature transition at roller bearing. Type of bearing and sealing method were modified based on these analyses. The temperature and vibration level measured at roller bearing showed that the modifications clearly improved the operational stability of MG Set.

The secondary excited induction generator in random wave input system

  • Kim, Moon-Hwan
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.209-214
    • /
    • 2009
  • The employment of the induction generator is preferable in the natural energy utilization by the minimum maintenance and the mechanical robustness, Another merit is also expected when it is connected to the power network system, because constant-voltage and constant frequency (CVCF) power generation is easily realized in spite of the variation of the rotor speed. However the induction generator needs much amount of the reactive power that reduces power factor in the primary side. The improvement of power factor in the primary side requires large VAR compensator, this point is solved, the merit of the induction machine as a main generator will become more established. This paper proposes a novel approach where the secondary is controlled by a PWM inverter not only to get CVCF power but also to improve the primary power factor. Basically the inverter is controlled so that the field current is supplied from the secondary side in this approach. The required capacity of the inverter is small, because only the slip power is controlled in the secondary side. In the experimental system where the sea wave torque simulator is used, the power factor is well improved by the microcomputer controlled PWM inverter.