• 제목/요약/키워드: Sludge Management

검색결과 160건 처리시간 0.03초

Waste treatment with the pilot scale ATAD and EGSB pig slurry management system followed by sequencing batch treatment

  • Lee, Young-Shin;Han, Gee-Bong
    • Environmental Engineering Research
    • /
    • 제20권3호
    • /
    • pp.277-284
    • /
    • 2015
  • Experiments for highly concentrated contaminants in pig waste slurry were carried out for the feasibility test of a pilot-scale innovative process scheme of engaging autothermal thermophilic aerobic digestion (ATAD) and expended granular sludge bed (EGSB) followed by sequencing batch reactor (SBR) system. Contaminants in pig waste slurry such as organic substance, total nitrogen (TN), ammonia nitrogen and total phosphorus (TP) contents were successfully reduced in the system. Total volatile solids (TVS) and chemical oxygen demands (COD) for organic matter in the feed were 32.92 g/L and 42.55 g/L respectively, and they were reduced by about 98.7% and 99.2%, respectively in the system. The overall removal efficiencies for TN and ammonium nitrogen were found to be 98.1 and 98.5%, respectively. The overall removal efficiency for total phosphorus was also found to be 92.5%. Faecal coliform density was reduced to <$1.2{\times}10^4CFU/g$ total solids. Biogas and $CH_4$ were produced in the range of 0.39-0.85 and $0.25-0.62m^3/kg$ [VS removed], respectively. The biogas produced in the system comprised of $295{\pm}26ppm$ (v/v) [$H_2S$].

Treatment of cutting-oily wastewater by electrocoagulation-flotation (ECF) process: Modeling approach

  • Chawaloesphosiya, Nattawin;Mongkolnauwarat, Jittrapa;Prommajun, Chayanin;Wongwailikhit, Kritchart;Painmanakul, Pisut
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.392-396
    • /
    • 2015
  • This work aims to investigate the oily wastewater treatment by the electrocoagulation-flotation (ECF) and propose a mathematical model for the efficiency prediction. Cutting oil was used to prepare the synthetic oily wastewater with submicron droplet sizes. The chemical coagulation by aluminium sulfate was firstly tested following by the electrocoagulation-flotation with aluminium electrodes. Both processes gave the effective treatment performance with the efficiencies higher than 90%. However, the ECF consumed less aluminium dosage as well as produced less sludge, which were its advantage on the chemical coagulation. The performance of the ECF was found to be affected by the current density, oil concentration, and reaction time according to the analysis by the design of experiment (DOE). Finally, the prediction model was proposed by two approaches, including linear and logarithm function. The latter model gave more accuracy prediction results in terms of treatment efficiency and duration in the lag and stable stages.

생물학적 영양소 제거공정의 적정 설계 및 운전인자 도출을 위한 간단한 수학적 접근법 (Simplified Mathematical Approach for Optimum Design and Operation Parameters of the Full-Scale BNR Processes)

  • 김태훈;하준수;박재홍;김성원;최의소
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.448-457
    • /
    • 2005
  • The conventional activated sludge processes were operated as a combined organic substrate removal and nitrification. So, it was necessary to provide with oxygen for both carbon and ammonia removal. But, in the BNR processes, nitrification is separated from carbon removal that causes fast ammonia oxidation and reduced oxygen demands. And most of the substrate is utilized by denitrification organisms and phosphorus accumulating organisms. with these appearances, mathematical model for BNR processes different from IWA ASM can be simplified and applied. In this study, it was performed that the existing equations as McKinney model, nitrification model published by U.S. EPA and oxygen demands from stoichiometry and the relationship between NUR and OUR were applied to full-scale BNR processes and the results were compared with the measured. and it is possible to make out the optimum design parameter from those equations.

기존 하수처리장 성능개선을 위한 NPR공정의 적용 (An Application of the NPR Process for the Treatability Improvement of an Existing Sewage Treatment Plant)

  • 문태훈;고광백;송의열
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.756-760
    • /
    • 2007
  • Most of the sewage treatment plants in Korea are being operated by using the conventional activated sludge process. Recently, as the water criteria have been strict with regard to such main culprits of eutrophication, the existing sewage treatment plants are obliged to upgrade their treatment technology to meet the criteria. Under such circumstances, this study was aimed at analyzing the conditions of an existing sewage treatment plants in Korea, and thereupon, test its treatment performance for the actual sewage water by operating a pilot plant. When the pilot plant was operated with the NPR process at the capacity of $30m^3/day$, the average contents of BOD, $COD_{Mn}$, SS, T-N and T-P in the effluents were 7.0 mg/L, 9.7 mg/L, 5.1 mg/L, 8.0 mg/L and 0.23 mg/L, respectively, which were very stable in general. Accordingly, if the NPR process used for this pilot plant to upgrade the treatment technology for the sewage treatment plat could be adopted, the effluent water quality criteria effective beginning from 2008 would be met.

대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책 (The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas)

  • 이장훈;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

인산염 마그네시아 시멘트에 의한 중금속 이온 고정화 (Solidification of Heavy Metal Ions Using Magnesia-phosphate Cement)

  • 최훈;강현주;송명신;정의담;김주성
    • 한국세라믹학회지
    • /
    • 제48권1호
    • /
    • pp.20-25
    • /
    • 2011
  • Since 1980's, many mines have been closed and abandoned due to the exhaustion of deposits and declining prices of international mineral resources. Because of the lack of post management for these abandoned mines, Farm land and rivers were contaminated with heavy metal ions and sludge. We studied on the solidification/stabilization of heavy metal ions, chromium ions and lead ions, using magnesia-phosphate cement. Magnesia binders were used calcined-magnesia and dead-burned magnesia. Test specimens were prepared by mixing magnesia binder with chromium ions and lead ions and activators. We analyzed the hydrates by reaction between magnesiaphosphate cement and each heavy metal ions by XRD and SEM-EDAX, and analyzed the content of heavy metal ions in the eruption water from the specimens for the solidification and stabilization of heavy metal ions by ICP. The results was shown that calcined magnesia binder is effective in stabilization for chromium ions and dead-burned magnesia binder is effective in stabilization for lead ions.

Combustion Generated Fine Particles, Trace Metal Speciation, and Health Effects

  • Linak, William P.
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.195-195
    • /
    • 2003
  • Combustion generated fine particles, defined as those with aerodynamic diameters less than 2.5 m, have come under increased regulatory scrutiny because of suspected links to adverse human health effects. Transition metals are of particular interest due to the results of a number of studies that have shown cardiopulmonary damage associated with exposure to these elements and their presence in coal, residual fuel oils, sewage sludge, and other combusted fuels and wastes. This lecture will review results from multi-di sciplinary studies being conducted at EPA and elsewhere examining the physical, chemical, and toxicological characteristics of combustion generated particles. The research describes how collaborative work between combustion engineers and health scientists can provide insight on how combustion processes affect particle properties and subsequent health effects as measured by a combination of in-vitro and in-vivo studies using a variety of animal models. The focus of this lecture is on the interdisciplinary approach required to address the problem. Difficulties are discussed. Engineering aspects involved in this approach are described in detail. Physical and chemical characterizations are performed using a variety of analytical approaches including new techniques of x-ray absorption fine structure (XAFS) spectroscopy and x-ray absorption near-edge structure (XANES) deconvolution of these spectra to gather metal speciation information.

  • PDF

음식물류 폐기물의 사료화 및 퇴비화 등 자원화 지원정책에 관한 연구 (Study on the Support Policy for Recycling Food Wastes into Feed & Compost)

  • 안상선
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제10권3호
    • /
    • pp.52-63
    • /
    • 2005
  • 근래 우리나라에는 음식물류 폐기물 등 유기성 폐기물과 관련하여 두 가지 주요한 정책이 추진되었다 하나는 1995 년에 전면 시행된 폐기물 종량제이고 또 하나는 폐기물관리법에 의한 유기성폐기물의 매립금지 조치이다. 이 두 정책의 시행으로 유기성폐기물의 발생원 감량과 퇴비화 및 사료화 등 재활용 기술의 발전이라는 긍정적인 효과를 거 두고 있으나 다른 한편으로는 법률적, 재활용의 하부구조, 기술적 측면에서 음식물류 폐기물 정책을 추진하는데 걸림돌로 작용하는 잠재된 문제점도 공존하고 있다. 본 연구에서는 음식물류 폐기물 자원화 정책의 문제점을 살펴보고 이에 대한 개선방안을 제시하고자 한다.

Studies on Environmental Impact of Pulp and Addtives in Liner Papermaking

  • Seo, Jin-Ho;Kim, Hyoung-Jin
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.441-444
    • /
    • 2006
  • A lot of water is using in the paper mill for dilution, washing, sealing, and other process operation. As the regulation of water environment has been more tightened than ever before, water management in the paper mill becomes the most important task. Topics on reducing fresh water and increasing recycling water have been studied. Further, an interest in zero-effluent system has been increased. The pH of waste water in paper mill is usually weak acidic or neutral. The waste water in the paper mill includes water insoluble organic materials that are not easy to be dissolved in the water, inorganic materials that never react with water and chemical additives that are used to recycled fiber. This study investigated on the effect of various materials used in paper mill on COD. This data could be used to control the environmental load in paper mill. COD caused by raw materials and NBDCOD (Non Bio Degradable COD) after the activated sludge process are investigated in this study. Results obtained in this study can be used in a simulation program designed to control environmental load in the paper mill.

  • PDF

혐기성 막 생물반응조를 이용한 하수처리의 최근 동향 (Recent trends in anaerobic membrane bioreactor treatment of domestic wastewater)

  • 신중헌;배재호;김정환
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.529-545
    • /
    • 2013
  • With the increasing concern on climate changes and energy shortage, anaerobic membrane bioreactors (AnMBR) become a promising alternative to aerobic processes for domestic wastewater treatment. Two major advantages of AnMBRs are energy production and sludge reduction. Recently, several different configurations of AnMBRs have been proved to produce high quality effluent at reasonable hydraulic retention time and ambient temperature. One of the major problems of the AnMBR is membrane fouling control, and some solutions are already suggested. Other problems to be solved before the full application of the AnMBR are recovery of dissolved methane, management of residual nutrients and sulfide. Considering the potential advantages and future technology development, AnMBR will become major domestic wastewater treatment process in near future.