• Title/Summary/Keyword: Slope plate

Search Result 137, Processing Time 0.032 seconds

Thixo-extrusion of Semi Solid 7075 Aluminum Alloys and Mechanical Properties of The Extrudates (반응고 7075 알루미늄 합금의 반용융 압출 및 압출재의 기계적 특성)

  • Choi, Tae-Young;Kim, Dae-Hwan;Kim, Soo-Bae;Shim, Sung-Young;Lim, Su-Gun
    • Journal of Korea Foundry Society
    • /
    • v.34 no.3
    • /
    • pp.87-93
    • /
    • 2014
  • Thixo-extrusion of semi-solid 7075 aluminum alloy and the mechanical properties of its extrudates were investigated. The semisolid alloy was prepared by a cooling slope cast. In other to perform thixo-extrusion, semi-solid 7075 aluminum alloy billets were reheated at the reheating conditions reported in a previous study. The maximum extrusion pressure in thixo-extrusion was 615MPa. This was lower than that of conventional hot extrusion ($P_{max}=940MPa$) at the same extrusion conditions due to the increased fluidity of the alloy billet in the semi-solid state. The values of Rockwell hardness (scale B) at the extrusion direction of the as thixoextruded bar were 48~53HRB and the difference in Rockwell hardness between the transverse direction and the extrusion direction was 5HRB or less. The results show that thxio-extrusion of semi-solid 7075 Al alloy improves the workability and anisotropic with the extrusion direction compared with hot extrusion of the conventional alloy.

A Study on the Small Disturbance Measurement of Liquid Film Thickness by $Moir\acute{e}$ Fringe ($Moir\acute{e}$ Fringe에 의한 액막 두께 미소 변위 측정 연구)

  • Jeon, H.S.;Kim, K.H.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.29-35
    • /
    • 1997
  • Liquid film thickness is measured by $moir\acute{e}$ topography which monitored liquid surface. $Moir\acute{e}$ fringe measurement techniques share the inherent simplicity found in optical interferometric techniques have the advantage of use over a greater range of displacement. $Moir\acute{e}$ fringe are the geometric interference patterns observed when two dense line grating are superposed. Light transmitted through a fixed line grating is deviated by the liquid film surface, producing a distored image of the grating. The $moir\acute{e}$ fringe produced by projection of this optically distored grating onto a second stationary grating permit visualization of the liquid surface and measurement of the liquid film thickness. This study measured the small amplitude of liquid film thickness to the $moir\acute{e}$ fringe pattern produced when spherical metal was dropped glycerin put)1 And the measurement of liquid film thickness flowing down an inclined plate are required to calculate the liquid slope in a position.

  • PDF

Application of Elastomeric Bearing for Railway Bridge (철도교량의 탄성받침 적용방안)

  • Kang, T.W.;Oa, S.W.;Kim, D.S.;Kang, Y.S
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1697-1702
    • /
    • 2010
  • It has been recognized for decades that the spherical bearing which is sliding on curved surface in the intrinsic behavior is optimized for the railway bridge requiring a large slope deflection. However, the spherical bearing is easily corrosived at the PSC girder bridge which is exposed to the outside so the normal function of bridge bearing is not fulfilled fully. It is common that the corrosion is happened at the operating plate of steel bridge bearing and generally it is necessary to replace the bridge bearing after 20~25 years. Accordingly, It costs multi billion dollars for maintenance each year and the necessity of improvement become a issue. Korea Rail Network Authority(KR) suggested to apply the Elastomeric bearing instead of Spherical bearing through the task of construction site of 2006. But the normal Elastomeric bearing is optimized for the Highway bridge so it needs the special consideration to satisfy each design condition required by railway bridge. As the result of examination of Elastomeric bearing at the railway bridge construction site, the stress is decreased by effective dispersion of earthquakes and the maintenance fee is also decreased.

  • PDF

Thixo Extrusion and Reheating Characteristics of Semi Solid A356 Alloy (반응고 A356 합금의 재가열 특성 및 반용융 압출)

  • Kim, Dae-Hwan;Jung, Hyun-Ju;Shim, Sung-Yong;Lim, Su-Gun;Lee, Sang-Yong
    • Journal of Korea Foundry Society
    • /
    • v.34 no.4
    • /
    • pp.123-129
    • /
    • 2014
  • This work presents the results of a thixo-extrusion process applied to aluminum alloy and and reheating characteristics of semi-solid A356 Alloy using have been discussed. The reheating experiment was performed using an electric resistance furnace and multi-stage heating for uniform reheating. The thixo-extrusion was performed at the optimal reheating conditions of the semi-solid A356 alloy, the the extrusion conditions were an extrusion ratio of 33 and ram speed of 6 mm/sec. The results showed that the thixo-extrusion of semi-solid A356 alloy fabricated by the cooling slope reduced the extrusion pressure by 180% in comparison with hot extrusion, and that a sound extrusion could be obtained in spite of the same extrusion ratio and strain rate.

A Study on the Correction of Beam Pattern for the Ultrasonic Attenuation Coefficient Estimation (초음파 감쇠계수 주정에 있어서 빔 형태의 보정에 관한 연구)

  • Kim, Gi-Uk;Choe, Heung-Ho;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 1987
  • In estimating the freguency-dependent attenuation coefficient, we analyzed the range-dependent ultrasonic beam and proposed the method of calculating the experimental equation of beam pattern in order to reduce the error on the influence of beam pattern. These experimental equations are divided into the spectral centroid and the spec ural standard deviation slope according to axial propagation length. These are repnesented by the first-order equation in the near field of the beam and the second- order eqLlatlon In the far field. In order to prove the validity of this method, the attenuation coefficients of the non-corrected ease and the corrected case are compared. Using the reflected signal from acryle plate, the attenuation coefficients were estimated by the spectral shift method ann the spectral difference method. The result shows attenuation coeffi talents after correction are better than attenuation coefficients before correction. And this method can be applied In vivo measurement.

  • PDF

The Effects of on CTA and Q-Angle with the Different Position of the Foot in the Standing Status (기립자세에서 발의 변화가 슬개대퇴골각과 종경골각에 미치는 영향)

  • Bae Sung-Soo;Lee Sang-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.203-225
    • /
    • 2002
  • An excessive Q-angle has been implicated in the development of knee injuries by altering the lower-extremity locomotion kinematics. The purpose of this study was performed to examine the correlation between the Q-angle and the CTA during pronation and supination of the foot in the standing status. The participants of this examination were 60 adult(30 men and 30 women) who had no orthopaedic and neurological impairment, aged between 20 and 40years. The foot tilt(FT1)is made of acrylic plate and the slope of the surface is altered as $0^{\circ}$ pronation$(10^{\circ},\;20^{\circ},\;30^{\circ})$ and supination $(10^{\circ},\;20^{\circ},\;30^{\circ})$. The results were as follows : 1. The result about the Q-angle and the CTA by comparing pronation and supination of the foot There was statistical significance difference in the left /right Q-angle and the left/right CTA with pronation and supination of the foot(P<0.05). 2. The result about correlation in the left /right lower-extremity There were positive correlation between the right Q-angle and the right CTA and negative correlation except the supination$(30^{\circ})$ between the left Q-angle and the left CTA.

  • PDF

Characteristics of Poly(methylphenyl)silane Photoreists (Poly(methylpheny) Silane Photoresist의 특성)

  • Kang, Doo-Whan;Chung, Nak-Jin
    • Applied Chemistry for Engineering
    • /
    • v.1 no.2
    • /
    • pp.161-167
    • /
    • 1990
  • Polymethylphenylsilane(PMPS) was synthesized with methylphenyldichlorosilane using metal sodium. Various sample coated on quartz plate were exposed and the yield of residual film was calculated. To obtain the fine image forming after developing and drying, optical transmittance characterization have to be considered. Exposure is described by three optical parameters X, Y, and Z. There parameters are normally determined from optical transmittance measurements of exposed PMPS films. Z parameter was determined from the initial slope of a transmittance according to exposure time. This set of function parameters provided a complete description of photoresist exposure and development and became the basis for the theoretical process models.

  • PDF

Measurement of Two-Dimensional Skin Friction Distribution Using the Overall Fringe Images (간섭영상을 이용한 이차원 표면전단응력 분포 측정에 관한 연구)

  • Lee Han-Sang;Lee Yeol;Yoon Woong-Sup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.87-94
    • /
    • 2006
  • An experimental research program providing knowledge to measure two-dimensional skin friction variation over a certain region of model surface is presented. In the oil-fringe imaging skin friction(FISF) technique, local slope of a thin oil applied on a test surface is measured from the interference fringe patterns on the oil surface, and its information is then related to the applied shear over the oil by the thin-oil lubrication theory. The FISF technique has been applied for a separation flowfield ahead of a circular cylinder vertically mounted on a flat plate, and it has been found that the FISF skin friction results show good comparison with the other numerical/experimental data obtained for similar conditions. implying an applicability of the technique.

A Linearly Polarized Long-Cavity Yb:YAG Laser with a Variable-Reflectivity Output Coupler (반사도 가변형 출력경을 갖는 긴 공진기형 선편광 Yb:YAG 레이저의 출력 특성 연구)

  • Kim, Hyun Chul;Lim, Han Bum;Kim, Hyun Su
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.38-43
    • /
    • 2015
  • We propose a linearly polarized long-cavity Yb:YAG laser with a variable-reflectivity output coupler and investigate its output characteristics. The variable output coupler consists of a polarized beam splitter and a quarter-wave plate. The linearly polarized laser has a long cavity length of about 3.7 m. The slope efficiency of the proposed laser is 19%, and the beam quality ($M^2$) is about 1.2.

A basic study of steel-joint connection method of composite precast concrete members (합성 PC부재의 Steel-joint Connection Method 개발 기초연구)

  • Kim, Geun-Ho;Lee, Dong-Hoon;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.10-11
    • /
    • 2013
  • Green Frame is a column-beam system formed by composite precast concrete column and beam connected with steel buried in both members. During the installation of Green columns, the columns of Green Frame, covering 3 floors per each piece and beams, the eccentricity can be observed due to the construction error and the weight of beam itself. Such eccentricity may have a little influence on a single frame, yet, it can develop critical issues to the installation of subsequent beams or beams on the upper floors in the context of a building as a whole that has multiple frames. These issues lead to delay in frame installation, decrease of productivity and increase of cost, etc. Therefore, this study presents a steel-joint connection method in order to solve the issues. The steel-joint connection method exists on slope plane and reinforcing plate in steel frame buried in composite PC members. Through this method, the issues can be resolved without requiring additional equipment or manpower.

  • PDF