• Title/Summary/Keyword: Slope Difference

Search Result 739, Processing Time 0.028 seconds

[Retracted]Analysis of Slope Safety by Tension Wire Data ([논문철회]지표변위계를 활용한 비탈면 안정성 예측)

  • Lee, Seokyoung;Jang, Seoyong;Kim, Taesoo;Han, Heuisoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.4
    • /
    • pp.5-12
    • /
    • 2015
  • Civil engineers have taken the numerous slope monitoring data for an engineering project subjected to hazard potential of slide. However, the topics on how to deal with and draw out proper information from the data related to the slope behavior have not been widely discussed. Recently, several researchers had installed the real-time monitoring system to cope with slope failure; however they are mainly focused on the hardware system installation. Therefore, this study tries to show how the measured data could be grouped and connected each other. The basic idea of analyzing method studied in this paper came from the clustering, which is the part of data mining analysis. Therefore, at the base of classification of time series data, the authors suggest three mathematical data analyzing methods; Average Index of different displacement ($AD_{i,j}$), Difference of average relative displacement ($\overline{RD}_{i,j}$) and Coordinate system of average and relative displacement ($\overline{RD}$, AD). These analyzing methods are based on the statistical method and failure mechanism of slope. Therefore they showed clustering relationships of the similar parts of the slope which makes the same sliding mechanism.

A Fast Locking Phase-Locked Loop using a New Dual-Slope Phase Frequency Detector and Charge Pump Architecture (위상고정 시간이 빠른 새로운 듀얼 슬로프 위상고정루프)

  • Park, Jong-Ha;Kim, Hoon;Kim, Hee-Jun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.82-87
    • /
    • 2008
  • This paper presents a new fast locking dual-slope phase-locked loop. The conventional dual-slope phase-locked loop consists of two charge pumps and two phase-frequency detectors. In this paper, the dual-slope phase-locked loop was achieved with a charge pump and a phase-frequency detector as adjusting a current of the charge pump according to the phase difference. The proposed circuit was verified by HSPICE simulation with a $0.35{\mu}m$ CMOS standard process parameter. The phase locking time of the proposed dual-slope phase-locked loop was $2.2{\mu}s$ and that of the single-slope phase-locke loop was $7{\mu}s$.

Comparison Study on Thermal Environment Characteristics in Each Region and the Seasons of Summer and Winter Through Air Temperature Analysis in Urban Areas (도시의 기온 분석을 통한 지역별 열 환경 특성 해석과 동·하절기 계절 간 비교연구)

  • Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.83-93
    • /
    • 2012
  • This study is to perform the effect of urbanization in urban and suburban districts, and to identify regional characters of climate according to the analysis of slope at rise, and descent of temperature and globe temperature, correlation between seasonal temperature analysis, and calculation of degree hour. According to this study, the result is summarized as follows. (1) The average temperature, rated from high to low, consists of residential area, Daegu weather station, intracity, green belt, water-front green belt, and suburban. (2) At the rise and descent of temperature, the result of the slope change of in each point may be one of the useful indexes to be able to perform the regional unique thermal characteristic, including the seasonal urbanization. (3) Although there is a difference between the surface of the earth and ambient environment. The result of the correlation of temperature between summer and winter is that temperature slope in urban districts was higher than in suburban districts, and the difference of slope was unvaried among the four observations in the same city region. (4) To show objectively, regional thermal characteristics in urban and suburban districts, the exponentiation of winter degree hour and summer degree hours were checked. The result of the exponentiation is that the more artificial a region, the lower index.

A Study of Characteristics on Weathering for Decomposed Granite Soils in Cutting Slope (화강토 지반 절취사면의 풍화특성에 관한 연구)

  • Lee, Song;Kim, Ju-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.451-458
    • /
    • 2001
  • The purpose of this study was to evaluate shear parameters on cutting slope of weathered granite soils by using small dynamic cone penetration test on the very moment of its cutting. The results were : On the relations among N$\_$c/, Li, and CEC, the condition of Li>6%, CEC>14(meq/100g) corresponds to that of N$\_$c/ values of 2∼30, and 3<CEC<14(meq/100g) to N$\_$c/=30∼50. Comparing the smallest penetration depth from two small dynamic cone penetration tests done at 5m below from the top of the slope on April 15th, October 31t. there was a l0cm difference. So we could find out the degree of weathering on the slope. And dividing the difference by 190 days (the whole testing time), we could know it's being weathered 0.052mm each day. The more N. value increases, the more shear parameters(internal friction angle ; $\phi$, cohesion : c) increase at a standard pressure($\sigma$>32㎪). So the condition of N$\_$c/=2∼50 corresponds to that of $\phi$=27∼50, c=12∼49㎪. From the above testing results, the N$\_$c/ values more correspond to $\phi$ values than c values. In conclusion, this study suggests that on small dynamic cone penetration test a penetration boundary line of 5 centimeters is decided at around Li=4%, CEC=3(meq/100g) which is classified as a strong weathering soil. It also shows that as Li increases CEC increases as well, while N$\_$c/ decreases.

  • PDF

Study on the Stability Analysis and Supporting Methods for the Spillway Slopes in Boryeong Dam (보령댐 여수로 사면의 안정성 분석 및 유지방안 연구)

  • 정소걸;한공창;최성웅;박연준
    • Tunnel and Underground Space
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1998
  • In this study, two dimensional and three dimensional numerical analysis were performed with a finite difference code for the safe maintenance of the spillway slope of the Boryeong dam. Results of the geological survey and the stereographic projection analysis on the discontinuities were used as input data for the numerical analysis. As a result, several suggestions were given such as the reinforcement of the local tension zone, the decrease in the angle of the slope, the drawdown of the pore pressure in the slope and the removal of the upper benches. A systematic and long-term monitoring system was also suggested.

  • PDF

A CONFUTER ANALYSIS ON THE ARTICULAR EMINENCE AND THE CONDYLAR PATH OF THE EDENTULUS PATIENT IN MANDIBULAR PROTRUSIVE MOVEMENT (무치악자의 하악전방운동시 관절융기와 과두운동로에 관한 컴퓨터 분석)

  • Lee Yeoun-Soo;Park Nam-Soo;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.321-337
    • /
    • 1992
  • The objective of this study was to compare the condylar path and the anterior angle of articular fossa and to analyze the pattern of condylar path in edentulus patients. Nineteen male and female edentulous patients with normal masticatory system ranging in age 42 to 78, without present symptoms and any history of TMJ disturbance were selected for this study. On the computer analysis on the transcranial radiographs of the TMJ, the angle of slope of articular eminance and condylar path to the Frankfort Horizontal Plane and the height of glenoid fossa was measured respectively, and stuied their interrelationship comparatively. Obtained results were asfollows. 1. The angle of the slope of articular eminence averaged 37.28 degree. and there was no significant difference between the right and left side. 2. The condylar path angle averaged 29.05 degree and there was no significant difference between the right and left side. 3. The height of the glenoid fossa averaged 8.11 mm and there was no significant difference between the right and left side. 4. The sequence of the frequence of condylar movement patterns were concavex curve(39.5% ), 'S' shape curve(34.2%), reverse 'S' shape(15.8%) and convex curve(10.5%). 5. The horizontal distance of the point of the changed curve of the condylar path averaged 2.91 mm. 6. The height of glenoid fossa was highly correlated to the slope of articular eminence and relatively highly correlated to tile condylar path and the condylar path was closely correlated to the slop of articular eminence.

  • PDF

Analysis of Rock Slope Stability Based on Fuzzy Approximate Reasoning (퍼지근사추론법에 의한 암반사면의 안정해석)

  • 기완서;김삼석;주승완
    • The Journal of Engineering Geology
    • /
    • v.11 no.2
    • /
    • pp.153-161
    • /
    • 2001
  • The quantitative evaluation of the stereo graphic projection, the limit equilibrium analysis, the finite difference analysis, the distinct element methocI is a analytical evaluation using many variables. Through the reliability analysis by the point estimation technique, uncertainty of other variables that have an effect on the stability of the rock slo~ was considered. The organized evaluation method of the approximate reasoning concept and using a fuzzy language was developed to confer and analysis the failure factors in planning and constructing the rock slope. Considering the result of the an- alysis, it was demonstrated that stability of entire sections can be evaluated through reliability analysis of point estimation technique. The results of stability evaluation by Fuzzy Approximate Reasoning is generally identical with the results of other existirw; analyses. As mentioned above, general and organized evaluation of special qualities of rock slope is possible using RMR Classification, Stereo Graphic Projection, Limit Equilibriwn Analysis, Finite Difference Analysis, Distinct Element Method, Point Estimation Technique, and Fuzzy Approximate Reasoning.

  • PDF

The 90° hybrid Coupler having the same output power slope at two output ports (두 개의 출력단자에 동일한 출력 전력 기울기를 갖는 90° hybrid Coupler)

  • Park, Ung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.85-88
    • /
    • 2016
  • Two output ports of $90^{\circ}$ hybrid-coupler are generally the same output power with $90^{\circ}$ phase difference. But, Two output ports of $90^{\circ}$ hybrid-coupler must be the different output slope characteristic about frequency because of the different electrical length. In $90^{\circ}$ hybrid-coupler being the same power distribution, 3-dB power distribution at two output ports only exists near the center frequency. And, the output power difference between two output ports increases in accordance with the further away from the center frequency. This paper proposes $90^{\circ}$ hybrid-coupler being the similar output slope characteristic of two output ports in wideband to modify the ${\lambda}/4$ transmission line of $35-{\Omega}$ characteristic impedance between input port and output port near input port. The power difference between two output ports of the proposed circuit is below 0.2dB over 20% bandwidth of the center frequency in ADS(advanced Design System).

  • PDF

Gender Comparison of Ratings of Perceived Exertion (RPE) as a Predictor of Exercise Intensity in College Students (RPE에 의한 운동강도 예측인자의 남녀 대학생 비교)

  • Kim, Do-Yeon;Lee, Jeong-Ah
    • Journal of Life Science
    • /
    • v.21 no.1
    • /
    • pp.9-14
    • /
    • 2011
  • Perceived exertion involves detection and interpretation of sensations arising from the body during physical exercise. Physiological variables such as heart rate and oxygen consumption positively correlate with ratings of perceived exertion (RPE). It is unknown whether the accuracy of predicting exercise intensity from RPE differs between men and women. Therefore, it was examined whether men or women could predict relative exercise intensity, determined by oxygen consumption, more accurately from RPE. Ten male and ten female young adult subjects aged 25.1${\pm}$3.52 yr volunteered to participate. RPE were determined by the Borg 15-category scale, and a standard Bruce treadmill protocol was used to perform graded exercise testing. There was no significant difference in slope means between males and females (p=0.501). No significant difference was observed when plotting rates of perceived exertion (RPE) vs. percentage of $VO_2$ max. The relative maximal oxygen consumptions ($VO_{2max,\;}_{rel}$) were 52.36${\pm}$7.35 ml/kg/min for males and 41.44${\pm}$6.71 ml/kg/min for females, respectively and there was a significantly high difference between the two groups in the relative $VO_{2max}$, as well as figures of 4.05${\pm}$0.36 l/min for males and 2.53${\pm}$0.39 l/min for females in the absolute $VO_{2max}$ in this study. There were no significant differences in slope, y-intercept, and standard error of estimate (SEE) between males and females. No significant difference with RPE according to exercise intensity was found between males and females. However, RPE was a useful predictor of exercise intensity in independent genders.

N100 Amplitude Slopes in Major Depressive Disorder, Bipolar Disorder, Schizophrenia and Normal Controls (주요 우울 장애, 정신분열병, 양극성 장애 및 정상 대조군에서의 N100 진폭경사)

  • Yang, Eunkyoung;Lee, Seung-Hwan;Oh, Sunghee;Kim, Sangrae
    • Korean Journal of Biological Psychiatry
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 2009
  • Objectives : N100 amplitude slope(the intensity dependence of the cortical auditory evoked potentials) is widely considered as an indirect indicator of central serotonergic neurotransmission. However, there are only a few studies about N100 amplitude slopes of major psychiatric disorders. In this study, we examined N100 amplitude slope differences among major depressive disorder(MDD), bipolar disorder(BD), schizophrenia (SCZ) and normal controls(NC). Methods : We measured the N100 amplitude slopes of 35 patients with MDD, 33 patients with BD, 27 patients with SCZ and 35 NC subjects. Amplitude differences from N1 to P2 at the five different sound intensities(55, 65, 75, 85 and 95dB) were examined at Cz electrode. The N100 amplitude slope was calculated as the linear regression of five N1/P2 peak-to-peak amplitudes across stimulus intensities. Results : BD patients showed significantly reduced N100 amplitude slope compared with NC(0.54${\pm}$0.70 vs. 0.96${\pm}$0.72, p=0.035). N100 amplitude slope of SCZ patients was significantly reduced compared with NC(0.50${\pm}$0.47 vs. 0.96${\pm}$0.72, p=0.027). N100 amplitude slope of BD patients was significantly lower than that of MDD patients(0.54${\pm}$0.70 vs. 0.94${\pm}$0.60, p=0.046). SCZ patients also showed significant reduction of N100 amplitude slope compared with MDD patients(0.50${\pm}$0.47 vs. 0.94${\pm}$0.60, p=0.036). There was no significant difference of N100 amplitude slope between MDD patients and NC(0.94${\pm}$0.60 vs. 0.96${\pm}$0.72, p=1.000). Conclusion : Interestingly, the N100 amplitude slopes of BD and SCZ were reduced compared to NC and MDD patients. Our results suggest the predictive use of N100 amplitude slope in making differential diagnoses of major psychiatric disorders. Clinical implications of N100 amplitude slope in major psychiatric disorders were discussed.

  • PDF