• Title/Summary/Keyword: Slit lamp

Search Result 57, Processing Time 0.025 seconds

Ocular manifestations in a patient with de novo Fabry disease

  • Lee, You Hyun;Shim, Kyu Young;Park, Sung Bae;Kim, Yu Cheol
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.2
    • /
    • pp.232-235
    • /
    • 2018
  • Fabry disease (FD) is an X-linked, recessively inherited, rare, progressive, disorder of glycosphingolipid metabolism affecting multiple organs resulting in organ dysfunction. It is rare to find only one FD affected subject with a de novo mutation. Here we report a case of a 41-year-old Asian male diagnosed with de novo FD. Comprehensive ophthalmological evaluation was performed using slit lamp, color fundus photography, optical coherence tomography, fluorescein angiography, and indocyanine green angiography. On slit lamp examination, cornea verticillata and slightly tortuous, and aneurysmal dilatation of inferior bulbar conjunctival vessels were observed. Other imaging modalities showed unremarkable findings. Cornea verticillata and inferior bulbar conjunctival vascular abnormalities may be detected earlier than other ocular abnormalities in de novo FDs like hereditary FDs.

DESIGN AND MANUFACTURING OF THE CASSEGRAIN INTERFACE MODULE OF THE BOAO ECHELLE SPECTROGRAPH

  • KIM KANG-MIN;JANG BE-HO;HAN INWOO;JANG JEONG GYUN;SUNG HYUN CHUL;CHUN MOO-YOUNG;HYUNG SIEK;YOON TAE-SEOG;VOGT STEVEN S.
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.4
    • /
    • pp.221-227
    • /
    • 2002
  • Cassegrain interface module (CIM) of the fiber-fed high resolution echelle spectrograph has been designed and manufactured for the 1.8 m reflector at the Bohynsan Optical Astronomy Observatory. We also constructed a long slit spectrograph attached to this CIM, which would replace the earlier rather inefficient medium dispersion spectrometer. We present detailed description for design and manufacturing concepts of the CIM which consists of a slit assembly, slit monitoring system, calibration lamp system and a long slit spectrograph, in order to provide how the overall system and each part. are constructed. The preliminary performance test carried out so far seems to indicate a successful result.

A Case of Cystinosis (시스틴증(Cystinosis) 1례)

  • Jung, Min Ho;Keun, Seung On;Lee, Soon Ju;Lee, Byung Churl
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.6
    • /
    • pp.615-619
    • /
    • 2003
  • Cystinosis, an autosomal recessively inherited lysosomal storage disease, results from impaired transport of the amino acid cystine out of cellular lysosomes. The consequent accumulation and crystallization of cystine destroys tissues, causing growth retardation, Fanconi syndrome, renal failure, eye problems, and endocrinopathies. The gene for cystinosis, CTNS, was mapped to chromosome 17p13. The diagnosis of cystinosis was made by measuring the leukocyte cystine content. The presence of typical corneal crystals on slit-lamp examination is also diagnostic. Since treatment with cysteamine has proved extremely effective, early diagnosis and treatment are critical aspects. We experienced a typical case of cystinosis in a 12-year-old boy with growth retardation.

Electron Mobility Calculations for the Positive Column of a Fluorescent Lamp (형광램프 양광주 내의 전자이동도 계산)

  • 지철근;장우진;이진우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.2
    • /
    • pp.55-58
    • /
    • 1988
  • Electron mobility which is a basic parameter to represent gas state, is calculated for 38mm 20W fluorescent lamp. 2 Electron Group Model is u&ed for electron distribution function. To prove this result electron mobility in 38mm 20W fluorescent lamp is measured at various wall temperatures. In order to obtain electric field strength of positive column, the sum of anode and cathode fall voltages assumed to be 15(VJ) and dual slit is used to measure positive column length. The measured and calculated result is potted under $10-80^{\circ}C$ wall temperature.

  • PDF

A Study on Prescription of RGP Contact Lens in Korean Optometrist (안경사의 RGP콘택트렌즈 처방 실태조사)

  • Kim, Young-Hoon;Baarg, Saangbai;Kim, Kwang-Bae;Kim, Dae-Hyoun;Lim, Byung-Kwan;Sun, Kyoung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.7-17
    • /
    • 2007
  • There has been an increase in rigid gas permeable contact lens prescription by the optometrists in Korea since 1995. Therefore, the aim of our study was to find out which equipment is needed for adequate RGP contact lens prescription and the level of the clinical knowledge that they have and the level of education for the patient, to seize about the extended lens education programmes for the Korean optometrist. Also, we tried to figure out the problem that they had in the RGP contact lens prescription, to develope the educational programs for students and to improve legal uncertainties, through this research. The result came out with the following through questionnaires of 400 male and female opticians who is in clinical field. The distributions of respondents are 270 male (67.5%), 130 female (32.5%), and 356 optometry major (89%). We found out the optometry-majored people had faster clinical lens prescriptions (p=0.000), 72.5% of opticians prescribe the RGP-Lenses, and 27.5% do not because of laking in experience (P=0.000). They responded that they need slit-lamp, button lamp, fluorescein dry paper, and etc,for prescription or fitting test. In regular-check-up (Follow-up), the result came out very low by 83% of respondents who are not getting it regularly. And 83.5% (334 people) of them wanted to have those Extended Educational Programs and also the Clinical Education Programs.

  • PDF

The Research of Fitting Status of R.G.P Lenses Inspected by Optometrists in In-Cheon and Kyung-Gi Region (인천·경기지역 안경사들을 대상으로 한 R.G.P 렌즈 착용 실태 조사)

  • Kim, In-Suk;Kim, Young-Pil;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.27-33
    • /
    • 2007
  • This research investigated the effects of spherical and aspherical R.G.P lenses which was performed by optometrists in In-Cheon and Kyung-Gi region. This research survey included various questions such as the fitting status, after-care method, preliminary test. Results of the survey revealed that the optometriests sold the asperical and spherical lenses with a ratio of 7:3, respectively, and most of them did not cheked Topography, Fluorescein test by slit lamp biomicroscope, Tear Break up time test, Schirmer test and so on. And, with fitted R.G.P lenses symptoms like light odd-feeling, congestion, eye-stimulus, dimness and dryness were frequently reported. The purposes of this study are to search for the ideal fitting check of R.G.P lens and remind the most important preliminary test for contact lens fitting.

  • PDF

A Case of Phthiriasis Palpebrarum in the Eyelids of a Child (소아 안검에서 관찰된 사면발이증 1례)

  • Lee, Jong Hyuck;Rah, Sang Hoon;Kim, Yoon Hee;Song, Won Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.6
    • /
    • pp.800-803
    • /
    • 2002
  • A two year old male child complained of foreign body sensations bilaterally, and an itching sensation at both upper and lower eyelids for 2 months of duration. He was diagnosed with Phthiriasis palpebrarum after observation of adult louse and nits on slit-lamp examination. The treatment was accomplished by mechanical removal of the lices and nits by forceps and scissors, and then irrigation with 20% fluorescein was done under general anesthesia. Antibiotic eyedrops and ointment were applied to both eyes. The morphologic evaluation was performed with light microscopy and scanning electron microscopy. The follow-up interval was every weeks for one month and no louse or nit was found under slit-lamp examination. So we concluded that the Phthiriasis palpebrarum was eradiated completely. We report a case of Phthriasis palpebrarum had been review of the literatures.

A Case of Cystinosis (시스틴증(cystinosis) 1례)

  • Jung, Min Ho;Keun, Seung On;Lee, Soon Ju;Lee, Byung Churl
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.4 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • Cystinosis, an autosomal recessively inherited lysosomal storage disease, results from impaired transport of the amino acid cystine out of cellular lysosomes. The consequent accumulation and crystallization of cystine destroys tissues, causing growth retardation, Fanconi syndrome, renal failure, eye problems, and endocrinopathies. The gene for cystinosis, CTNS, was mapped to chromosome 17p13. The diagnosis of cystinosis is made by measuring the leukocyte cystine content and the presence of typical corneal crystals on slit-lamp examination is also diagnostic. Since treatment with cysteamine has proved extremely effective, early diagnosis and treatment are critical aspects. We experienced a typical case of cystinosis in a 12-year-old boy with growth retardation.

  • PDF

Two Cases of Corneal Edema Due to Vaporized Amine (기화된 아민에 의한 각막부종 2예)

  • Hwang, Yousook;Cho, Yang Kyung
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1077-1081
    • /
    • 2018
  • Purpose: We report two cases of corneal edema in patients who presented with bilateral blurry vision due to vaporized amines while working in a polyurethane processing plant. Case summary: A 28-year-old male presented with bilateral blurred vision. His work involved solidifying polyurethane liquid and he often found himself exposed to polyurethane heat and gas. Purpose: We report two cases of corneal edema in patients who presented with bilateral blurry vision due to vaporized amines while working in a polyurethane processing plant. Case summary: A 28-year-old male presented with bilateral blurred vision. His work involved solidifying polyurethane liquid and he often found himself exposed to polyurethane heat and gas. On examination, the patient's uncorrected visual acuity (UCVA) was 20/40 (right) and 30/50 (left). A slit lamp examination revealed subepithelial microbullae in both eyes. The central corneal thickness (CCT) was also increased in both eyes, measuring $698{\mu}m$ (right) and $672{\mu}m$ (left). After prescribing 0.5% moxifloxacin and, 1% fluorometholone eye drops for 3 days in both eyes, the UCVA recovered to 20/40 (right) and 20/20 (left). The CCT decreased to $644{\mu}m$ (right) and $651{\mu}m$ (left), and the microbullae improved significantly in the left eye. The second patient was a 34-year-old female who presented with bilateral decreased visual acuity while at work. She worked in a factory that produced car seat filling. Her UCVA was 20/25 (right) and 20/20 (left). The CCT by specular microscopy was $537{\mu}m$ (right) and $541{\mu}m$ (left). On slit lamp examination, both eyes demonstrated bilateral central subepithelial edema. The patient did not attend any follow-up outpatient appointments after the initial presentation. Conclusions: Exposure to vaporized amines such as polyurethane may causereversible corneal toxicityeven without direct contact. Further consideration should be given to ocular safety and protection from amine compounds in the industrial field.On examination, the patient's uncorrected visual acuity (UCVA) was 20/40 (right) and 30/50 (left). A slit lamp examination revealed subepithelial microbullae in both eyes. The central corneal thickness (CCT) was also increased in both eyes, measuring $698{\mu}m$ (right) and $672{\mu}m$ (left). After prescribing 0.5% moxifloxacin and, 1% fluorometholone eye drops for 3 days in both eyes, the UCVA recovered to 20/40 (right) and 20/20 (left). The CCT decreased to $644{\mu}m$ (right) and $651{\mu}m$ (left), and the microbullae improved significantly in the left eye. The second patient was a 34-year-old female who presented with bilateral decreased visual acuity while at work. She worked in a factory that produced car seat filling. Her UCVA was 20/25 (right) and 20/20 (left). The CCT by specular microscopy was $537{\mu}m$ (right) and $541{\mu}m$ (left). On slit lamp examination, both eyes demonstrated bilateral central subepithelial edema. The patient did not attend any follow-up outpatient appointments after the initial presentation. Conclusions: Exposure to vaporized amines such as polyurethane may causereversible corneal toxicityeven without direct contact. Further consideration should be given to ocular safety and protection from amine compounds in the industrial field.

Fabrication of Prototype vuv Spectrometer & Liquid Target System Containing Hydrogen

  • Lee, Yun-Man;Kim, Jae-Hun;Kim, Jin-Gon;An, Byeong-Nam
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.586-586
    • /
    • 2012
  • The vuv spectrometer for ITER main plasma measurement is designed as a five-channel spectral system. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The overall system performance was verified by comparing the measured spectral resolutions with the calculated spectral resolutions. And we also have developed liquid jet target system. This study is about a neutron generator, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the ones operating at high neutron fluxes and maintained relatively thin with no need for water cooling. In this study, liquid target containing hydrogen has been developed and tested.

  • PDF