• Title/Summary/Keyword: Slave module

Search Result 61, Processing Time 0.033 seconds

Digital Load Sharing Method for Converter parallel Operation (컨버터 병렬운전을 위한 디지털 부하분담 기법)

  • Yoo, Kwang-Min;Kim, Won-Yong;Park, Seung-Hee;Lee, Dong-Hoo;Kim, Yun-Sung;Jeong, Yu-Seok;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.150-157
    • /
    • 2012
  • This paper presents CAN-based parallel-operation and load-sharing techniques for the communication server power supply. With the load information obtained through CAN communication, each modules performs its current control independently and the power unbalance caused by impedance differences of converter modules can be reduced. In conventional method, slave modules are controlled by master module. On the other hand, the proposed load share algorithm uses the Multi-Master method. Therefore, accurate load sharing can be accomplished by the reference structure of each module's average current. Each converter has two stages and it is separated into PFC, which is responsible for harmonic regulation, and LLC resonant converter, which controls output voltage. To verified the performance of the proposed method, two 2KW prototypes has been implemented and experimented.

Implementation and Experimental Evaluation of Bandwidth Allocation Scheme on MS/TP Protocol (MS/TP 프로토콜에서 대역폭할당기법 구현 및 실험적 평가)

  • Kwon, Young-Chan;Hong, Seung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.11
    • /
    • pp.1144-1155
    • /
    • 2006
  • Digital communication networks have become a core technology in advanced building automation systems. BACnet(Building Automation and Control networks) is a standard data communication protocol designed specifically for building automation and control systems. BACnet adopts Master-Slave/Token-Passing(MS/TP) protocol as one of its field level networks. In this study, we introduce a method of implementing a bandwidth allocation scheme in the MS/TP protocol. The bandwidth allocation scheme improves the capability of real-time communication of the original MS/TP protocol. The bandwidth allocation scheme introduced in this paper can be easily implemented in the existing MS/TP protocol with a slight modification. In this study, we actually developed the hardware and firmware of the modified MS/TP communication module in which the bandwidth allocation scheme is implemented. Using the modified MS/TP communication module, we developed an experimental model in order to examine the validity of the bandwidth allocation scheme in the MS/TP protocol. Experimental results show that the modified MS/TP protocol satisfies the requirements of real time communication for periodic and urgent messages of BACnet communication services.

Load-Sharing Algorithm using Digital Parallel Communication (디지털 병렬 통신을 이용한 부하분담 알고리즘)

  • Park, Seong-Mi;Kim, Chun-Sung;Lee, Sang-Hyeok;Lee, Sang-Hun;Park, Sung-Jun;Lee, Bae-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.50-57
    • /
    • 2011
  • In this paper, we proposes a new load-sharing algorithm with a ATmega2560 based digital communication. Proposed algorithm is different from conventional analog method. The high speed communication digital control is performed. To apply the digital communication and real-time control for time-sharing token bus method, we implemented high efficient load-sharing and redundancy. Also this system make down the price by auto ID algorithm and system response is improved by controller's voltage and current integral value sharing. In parallel system prototype, each module have controller and performed load-sharing according to master module integral value. In this paper, we verify the validity of proposed algorithm using PSIM program and prototype.

Design and Control of Wire-driven Flexible Robot Following Human Arm Gestures (팔 동작 움직임을 모사하는 와이어 구동 유연 로봇의 설계 및 제어)

  • Kim, Sanghyun;Kim, Minhyo;Kang, Junki;Son, SeungJe;Kim, Dong Hwan
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.1
    • /
    • pp.50-57
    • /
    • 2019
  • This work presents a design and control method for a flexible robot arm operated by a wire drive that follows human gestures. When moving the robot arm to a desired position, the necessary wire moving length is calculated and the motors are rotated accordingly to the length. A robotic arm is composed of a total of two module-formed mechanism similar to real human motion. Two wires are used as a closed loop in one module, and universal joints are attached to each disk to create up, down, left, and right movements. In order to control the motor, the anti-windup PID was applied to limit the sudden change usually caused by accumulated error in the integral control term. In addition, master/slave communication protocol and operation program for linking 6 motors to MYO sensor and IMU sensor output were developed at the same time. This makes it possible to receive the image information of the camera attached to the robot arm and simultaneously send the control command to the robot at high speed.

Circulating Current Reduction Method Using High Frequency Voltage Compensation in Asynchronous Carriers for Modular Scalable Inverter System (Modular Scalable Inverter System에서 캐리어 비동기시 고주파 전압 보상을 이용한 순환전류 저감 기법)

  • Choi, Seung-Yeon;Kang, Shin-Won;Im, Jun-Hyuk;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.71-77
    • /
    • 2019
  • This study proposes a circulating current reduction method that uses high-frequency voltage compensation when carrier phase difference occurs between two inverters in MSIS. In MSIS, inverters are configured in parallel to increase power capacity and to increase efficiency by using inverters only as needed. However, in the parallel inverter structure, circulating current is inevitably generated. Circulating current increases the stress on the switch, adversely affects the current control performance, and renders load sharing difficult. The proposed method compensates for the output voltage reference of the slave module by using the high-frequency voltage so that the switching pattern of each module is matched even in asynchronous carriers. The validity of the proposed method is verified by simulations and experiments with 600 W IPMSM.

Implementation of Bandwidth Allocation Scheme in the MS/TP Protocol (MS/TP 프로토콜에서 대역폭할당기법구현 및 실험적 검증)

  • Hong, Seung-Ho;Song, Won-Seok;Kwon, Young-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.52-55
    • /
    • 2004
  • Digital communication networks have become a core technology in advanced building automation systems. BACnet(${\underline{B}}uilding$ ${\underline{A}}utomation$ and ${\underline{C}}ontrol$ ${\underline{net}}works$) is a standard data communication protocol designed specifically for building automation and control systems. BACnet adopts Master-Slave/Token-Passing (MS/TP) protocol as one of its field level networks. In this study, we introduce a method of implementing bandwidth allocation scheme in the MS/TP protocol. The bandwidth allocation scheme improves the capability of real-time communication of the original MS/TP protocol. The bandwidth allocation scheme introduced in this paper can be easily implemented in the existing MS/TP protocol with a slight modification. In this study, we actually developed the hardware and firmware of MS/TP module in which bandwidth allocation scheme is implemented.

  • PDF

Application Technology and Development of CAN Fieldbus Modules for Building Automation System (빌딩시스템용 CAN 필드버스 모듈개발 및 적용에 관한 연구)

  • Lee, Hoon-Jae;Yoon, Chung-Sup;Hong, Won-Pyo;Lee, Jung-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.397-403
    • /
    • 2004
  • The controller area network(CAN) was originally developed to support cheap and rather simple automative applications, However, because of the its performance and low cost, it is also being considered in automated manufacturing and process control environments to interconnect intelligent devices, such as modem sensors and actuators. This paper presents a new application technology of the developed CAN control modules for the automated doors in building automation system. Key pad and RF methods are used to open and close the automated door by the slave CAN module with CAN protocol. BAS application technology of CAN field bus modules is also presented firstly in our nation.

  • PDF

Development of optical dual-sensors for submersion monitoring using zigbee-based wireless sensor networks (지그비 기반 센서 네트워크를 이용한 침수감지용 광 이중센서 개발)

  • Key, Kwang-Hyun;Kim, Hyung-Pyo;Sohn, Kyung-Rak
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.184-190
    • /
    • 2010
  • In this paper, a remote submersion warning system based on multi-mode optical fiber(MMF) sensors and a wireless sensor network(WSN) are proposed. To improve the reliability and stability of the sensors, the dual optical fiber sensors combined to the optical coupler are demonstrated. A slave zigbee as a wireless sensor module was used as a platform to monitor and record the signal from the MMF sensors and then transmits these information to a master zigbee wirelessly. The monitoring system running the $LabVIEW^{(R)}$ software was connected to the internet to support the short message service(SMS) through extensible markup language(XML) web service. No matter where the managers are, they can always receive the real-time remote-monitoring data for safety check.

Control Algorithm of Phase Synchronization in Single-Phase Serial UPS Module (단상 직렬 UPS 모듈의 위상동기화 제어 알고리즘)

  • Baek, Seung-Ho;Lee, Soon-Ryung;Lee, Taek-Ki;Won, Chung-yuen
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.61-62
    • /
    • 2015
  • 본 논문에서는 단상 UPS 모듈을 직렬로 연결 시 모듈간의 위상을 동기화하는 제어 알고리즘을 제안한다. 단상 직렬 모듈 UPS 시스템을 구성할 때, 각 모듈의 위상이 동기화 되어 있지 않는다면 직렬 연결된 출력단을 통해 부하에 불안정한 전력을 공급하게 된다. 따라서 직렬 구성으로 각 모듈의 출력전압 위상을 동기화하여 안정적인 출력전압 제어가 필요하다. 기존에는 CAN통신을 이용했지만 본 논문에서는, Master, Slave 모듈의 PLL 기법을 이용한 순차적인 제어를 통해 위상을 동기화시킬 수 있는 제어 알고리즘을 제안한다. 제안하는 제어 알고리즘은 시뮬레이션을 통해 타당성을 검증하였다.

  • PDF

Implementation and simulation a slave module based on MVB of the TCN(IEC 61375-1) (TCN(IEC-61375-1)의 MVB 기반 슬레이브 컨트롤러 구현 및 시뮬레이션)

  • Sul, Jaeyoon;Kim, Seok-Heon;Park, Jaehyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.573-574
    • /
    • 2009
  • 열차 통신의 목적은 분산 제어 시스템에서 빠르고 정확한 데이터 교환에 있다. 이를 위하여 개발되고 1999년 IEC와 IEEE에 의해 국제 규격으로 승인된 TCN(Train Communication Network)은 차량간 통신 버스인 WTB(Wired Train Bus)와 차량내 통신 버스인 MVB(Multifunction Vehicle Bus)의 이중 계층 구조로 구성되며 TCN의 데이터 서비스는 프로세스 데이터, 메시지 데이터, 관리용 데이터의 세가지 데이터 서비스로 구분된다. MVB는 전송 가능한 데이터 서비스에 따라 디바이스의 클래스가 나눠지게 된다. 본 논문에서는 MVB에서 버스 마스터의 프레임에 따라 데이터를 보낼 수 있는 슬레이브 컨트롤러의 구성과 시뮬레이션을 통해 구현된 장치의 기능이 국제 표준의 제안사항들을 따르고 있는 지 증명한다.