• 제목/요약/키워드: Slab Strength

검색결과 672건 처리시간 0.026초

활절점으로 연결된 철근콘크리트 슬래브 내력에 기존 슬래브 철근이 미치는 영향 (Effection of The Existing Reinforcement on The Strength of Reinforced Concrete Slabs Connected by Hinged Jointeds)

  • 심규관;김상식;최광호;임주혁;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.271-274
    • /
    • 2005
  • In this research, 13 RC slabs connected by hinged joints were tested. the new slab was connected to the existing slab by hinge joint injecting dowel bars between two slabs. Main parameters of the slabs were the spacing of the dowel bars (150mm, 300mm, and 450mm) and the locations of the longitudinal reinforcement of the old slab. The test results indicated that the joint strength of the RC test slabs having various types of dowel bars was about twice that calculated by the ACI 318-02 code. The locations of the longitudinal reinforcement of the old slab slightly increased the strength of the slabs connected by hinged joints.

  • PDF

Punching performance of RC slab-column connections with inner steel truss

  • Shi, Qingxuan;Ma, Ge;Guo, Jiangran;Ma, Chenchen
    • Advances in concrete construction
    • /
    • 제14권3호
    • /
    • pp.195-204
    • /
    • 2022
  • As a brittle failure mode, punching-shear failure can be widely found in traditional RC slab-column connections, which may lead to the entire collapse of a flat plate structure. In this paper, a novel RC slab-column connection with inner steel truss was proposed to enhance the punching strength. In the proposed connection, steel trusses, each of which was composed of four steel angles and a series of steel strips, were pre-assembled at the periphery of the column capital and behaved as transverse reinforcements. With the aim of exploring the punching behavior of this novel RC slab-column connection, a static punching test was conducted on two full-scaled RC slab specimens, and the crack patterns, failure modes, load-deflection and load-strain responses were thoroughly analyzed to explore the contribution of the applied inner steel trusses to the overall punching behavior. The test results indicated that all the test specimens suffered the typical punching-shear failure, and the higher punching strength and initial stiffness could be found in the specimen with inner steel trusses. The numerical models of tested specimens were analyzed in ABAQUS. These models were verified by comparing the results of the tests with the results of the analyzes, and subsequently the sensitivity of the punching capacity to different parameters was studied. Based on the test results, a modified critical shear crack theory, which could take the contribution of the steel trusses into account, was put forward to predict the punching strength of this novel RC slab-column connection, and the calculated results agreed well with the test results.

슬래브-기둥 접합부에 대한 전단강도모델 (Shear Strength Model for Slab-Column Connections)

  • 최경규;박홍근;김혜민
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.585-593
    • /
    • 2010
  • 선행연구에서 제안된 변형률기반 전단강도모델에 근거하여, 슬래브-기둥 내부 및 외부접합부의 직접뚫림전단강도와 불균형휨모멘트강도를 정확하게 평가할 수 있는 강도모델을 개발하였다. 슬래브-기둥 접합부는 뚫림전단파괴에 앞서서 휨균열에 의해서 손상을 받으므로, 이 연구에서는 위험단면의 압축대에서 대부분의 전단저항이 발휘된다고 가정하였다. 슬래브 휨모멘트에 의해서 유발되는 압축수직응력이 콘크리트 압축대의 전단강도에 미치는 영향을 고려하기 위하여, 다축응력 상태에 대한 콘크리트 재료파괴기준을 이용하였다. 그 결과 위험단면의 전단성능이 휨손상의 정도에 따라서 정의되었다. 외부접합부는 비대칭적인 위험단면을 가지고 있으므로 하중재하방향을 고려하여 휨모멘트강도를 정의하였다. 실험 결과와 비교 결과, 제안된 강도모델은 현행 설계기준 보다 실험체의 강도를 더 정확하게 추정하는 것으로 밝혀졌다.

구조해석에 의한 파이프서포트의 내력비교에 관한 연구 (A Study on the Strength Comparison of Steel Pipe Support using the Structural Analysis Program)

  • 백신원;박종근
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.67-71
    • /
    • 2008
  • Formwork is a temporary structure that supports its weight and that of fresh concrete as well as construction live loads. Slab formwork consists of sheathing, stringer, hanger and shore. In construction site, pipe supports are usually used as shores which are consisted of the slab formwork. In this study, compressive strength of 80 pipe supports was measured by knife edge test and plate test. Buckling load of pipe supports was analyzed by structural analysis program(MlDAS). Theoretical buckling load with/without initial deformation was got by theoretical analysis. According to these results, buckling load which was analyzed by structural analysis program(MlDAS) was larger than compressive strength of knife edge test and plate test. Theoretical buckling load without initial deformation was larger than compressive strength of knife edge test and plate test. But Theoretical buckling load with initial deformation was lower than compressive strength of knife edge test and plate test. Initial deformation equation for test method according to the pipe support length was suggested. Therefore, the present study results will be used to design the slab formwork safely.

조강형 결합재를 사용한 콘크리트의 양생온도에 따른 경화특성 실험적 평가 (An experimental evaluation of hardened property of concrete using early-strength-binder with curing temperature)

  • 김광기;김영선;이주호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.88-89
    • /
    • 2015
  • In cold weather, the speed of concrete strength development is slow. As a result, construction speed becomes slow and it is problem for all construction site to solve this. So in this study, to shorten removing frame time after placing concrete, mix proportion using early-strength-binder(ESB) and curing method such as using heat line in concrete was considered. At first, concrete mix proportion was examined at -5℃ temperature between ordinary portland cement(OPC) and ESB. And second step, concrete, using mix proportion with OPC, was examined according to curing method(: 1) heat line used and 2) no heat line) and kinds of form (: 1) Deck slab, 2) Half PC slab and 3) SOG slab). All cases are same condition: slab thickness is 1,500mm, double-bubble sheet is used as a curing sheet after placing concrete. After the test, OPC is enough to get strength compared to ESB in special condition and 48~60 hours is needed according to form condition.

  • PDF

콘크리트 강도에 따른 바닥판 수직진동에 대한 적정 두께 제안 (The Adequate Slab Thickness Satisfied with the Vertical Floor Vibration Criteria for Several Concrete Compressive Strength)

  • 남상욱;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.659-662
    • /
    • 2003
  • Recently, the floor thickness in residence may not be satisfied with the floor vibration criteria although the thickness is evaluated by the serviceability requirements in current design provisions. Thus it is necessary to develop the procedure to determine slab thickness satisfied with the floor vibration criteria. In this study, We proposed the methods to determine the slab thickness satisfied with the vertical floor vibration criteria for several concrete compressive strength of flat plate floor systems. For this purpose Monte Carlo simulation procedure was adopted and both randomness inherent in young modulus of concrete and heel drop intensity were accounted.

  • PDF

Kaiser Truss를 사용한 일방향 슬래브의 휨 거동에 관한 연구 (An Experimental Study on the Flexural Behavior of Slabs Using Kaiser Truss)

  • 김형근;곽노현;류승곤;이희발;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.30-35
    • /
    • 1994
  • In order to investigate on the behavior of one-way slab with Kaiser. Truss, such as flexural strength, failure mode, and ductile capacity, a total of twenty specimens have been tested and compared with the R.C slab without Kaiser Truss. The major variables are Kaiser Truss intervals(30, 40, 60cm), half slab thickness. Test results showed that support interval of half pc slab can be determined by the flexural strength which causes the concrete crack and there are horizontal cracks between upper concrete and half slab in the connection of the specimen with kaiser truss interval 60cm.

  • PDF

Nonlinear modeling of flat-plate structures using grid beam elements

  • Tian, Ying;Chen, Jianwei;Said, Aly;Zhao, Jian
    • Computers and Concrete
    • /
    • 제10권5호
    • /
    • pp.489-505
    • /
    • 2012
  • This paper presents a simplified grid beam model for simulating the nonlinear response of reinforced concrete flat-plate structures. The beam elements are defined with nonlinear behavior for bending moment and torsion. The flexural stiffness and torsional strength of the beam elements are defined based on experimental data to implicitly account for slab two-way bending effects. A failure criterion that considers the interaction between the punching strength and slab flexural behavior is incorporated in the model. The effects of bond-slip of slab reinforcement on connection stiffness are examined. The proposed grid beam model is validated by simulating large-scale tests of slab-column connections subjected to concentric gravity loading and unbalanced moment. This study also determines the critical parameters for a hysteretic model used to simulate flat-plates subjected to cyclic lateral loading.

리브 보강된 SC구조 벽-바닥 접합부의 거동 및 내력 평가 (Behavior and Strength of Rib Stiffened SC Wall-slab Connection)

  • 박정학
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.349-359
    • /
    • 2014
  • 강판콘크리트(SC)구조 벽-바닥접합부는 표면 강판에 의해 콘크리트가 나뉘게 되며 이 때문에 바닥 단부의 응력 전달기구가 RC구조의 것과 다를 것으로 예상된다. 따라서 본 연구에서는 리브가 부착된 SC구조 벽-바닥 실험체의 거동 및 내력평가를 수행하였다. 리브가 부착된 SC벽바닥 접합부의 접합성능을 확인하기위하여 7가지의 접합부 모형을 제작하고 단조 가력실험을 수행하여 구조내력 및 거동특성을 실험결과분석을 통해 고찰하였다. 제안식의 신뢰성을 확보하기위해 유한요소 해석을 수행하였다. 실험체 변수로는 가력지점, 마찰계수이며 이들의 영향에 대해 검토되었다. 실험체 파괴모드 분석을 통해 접합부 내력을 확인하였다. 제안식은 대부분 보수적인 값으로 확인되었다.

재사용 파이프서포트의 내력변화 연구 (1) (A Study on the Strength Change of Used Pipe Support (1))

  • 백신원;노민래
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.93-97
    • /
    • 2004
  • Slab formwork consists of sheathing, stringer, hanger and shore. There are several types of adjustable individual shores. In constructions site, pipe supports are usually used as shores. The strength of a pipe support is decreasing as it is frequently being used at the construction site. In this study, 2857 pipe supports were bought to fine out the strength change of used pipe support and unused pipe supports according to aging. Among these pipe supports, 2337 pipe supports were lent to the construction companies free of charge. Compressive strength was measured by knife edge test and plate test at each 3 month. Test results show that the strength of unused pipe supports almost equaled to the strength of new pipe supports until 191 days, but the strength of used pipe supports at 191 days was lower than the strength of new pipe supports. So, the strength of used pipe supports at 191 days was not satisfied the specification of KS F 8001. According to these results, it shows that attention has to be paid to formwork design using used pipe supports. Therefore, the paresent study results will be able to provide a firm base to design slab formwork and test the performance of used temporary structure and prevent formwork collapses.