• Title/Summary/Keyword: Skin reference

Search Result 212, Processing Time 0.027 seconds

A Bundled Educational Solution to Reduce Incorrect Plaster Splints Applied on Patients Discharged from Emergency Department

  • Chia Wei Jennifer Ting;Shu Fang Ho;Fatimah Lateef
    • Quality Improvement in Health Care
    • /
    • v.29 no.2
    • /
    • pp.64-84
    • /
    • 2023
  • Purpose:Plaster splints are routinely performed in the Emergency Department (ED) and avoidable complications such as skin ulcerations and fracture instability arise mainly due to improper techniques. Despite its frequent use, there is often no formal training on the fundamental principles of plaster splint application for a medical officer rotating through ED. We aim to use Quality Improvement (QI) methodology to reduce number of incorrect plaster splint application to improve overall patient care via a bundled educational solution. Methods: We initiated a QI program implementing concepts derived from the Institute for Healthcare Improvement models, including Plan-Do-Study-Act (PDSA) cycles, to decrease the rate of incorrect plaster splint application. A bundled education solution consisting of three sequential interventions (practical teaching session, online video lecture and quick reference cards) were formulated to specifically target critical factors that had been identified as the cause of incorrect plaster splints in ED. Results: With the QI intervention, our overall rate of incorrect plaster splints was reduced from 84.1% to 68.6% over a 6-month period. Conclusion: Following the QI project implementation of the bundled educational solution, there has been a sustained reduction in incorrect plaster splints application. The continuation of the training program also ensures the sustainability of our efforts in ED.

Evaluations of a Commercial CLEANBOLUS-WHITE for Clinical Application

  • Geum Bong Yu;Jung-in Kim;Jaeman Son
    • Progress in Medical Physics
    • /
    • v.35 no.1
    • /
    • pp.10-15
    • /
    • 2024
  • Purpose: This study aimed to comprehensively investigate the diverse characteristics of a novel commercial bolus, CLEANBOLUS-WHITE (CBW), to ascertain its suitability for clinical application. Methods: The evaluation of CBW encompassed both physical and biological assessments. Physical parameters such as mass density and shore hardness were measured alongside analyses of element composition. Biological evaluations included assessments for skin irritation and cytotoxicity. Dosimetric properties were examined by calculating surface dose and beam quality using a treatment planning system (TPS). Additionally, doses were measured at maximum and reference depths, and the results were compared with those obtained using a solid water phantom. The effect of air gap on dose measurement was also investigated by comparing measured doses on the RANDO phantom, under the bolus, with doses calculated from the TPS. Results: Biological evaluation confirmed that CBW is non-cytotoxic, nonirritant, and non-sensitizing. The bolus exhibited a mass density of 1.02 g/cm3 and 14 shore 00. Dosimetric evaluations revealed that using the 0.5 cm CBW resulted in less than a 1% difference compared to using the solid water phantom. Furthermore, beam quality calculations in the TPS indicated increased surface dose with the bolus. The air gap effect on dose measurement was deemed negligible, with a difference of approximately 1% between calculated and measured doses, aligning with measurement uncertainty. Conclusions: CBW demonstrates outstanding properties for clinical utilization. The dosimetric evaluation underscores a strong agreement between calculated and measured doses, validating its reliability in both planning and clinical settings.

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.

Comparison between the method of the measurement 25 Vitamin D3 (25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰)

  • Kim, dae-won;Lee, jung-hee;Jung, an-na;Seo, so-yoen
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.112-114
    • /
    • 2015
  • Purpose Vitamin D to Anti- Rickets both steroid compounds showing activity, By acting on bone tissue secretary and the key to maintain serum Ca homeostasis. The blood level of vitamin D is the largest in D3 that the concentration of the metabolite is reflected in the holding state of vitamin D in vivo. Sunlight to change the 7-dehydrocholesterol in the skin and through the skin to D3, In the liver in combination with the D2 and D3 D4 changes. The Radioimmunoassay(RIA) method is measuring the D 3, the sensitivity can be measured also difficult trace substance to measure the normal test because it is very sensitive, but recently, a check is possible, for the Total D3 in Chemimicroparticle immunoassay(CMIA) or Chemiluminescent immunoassay(CLIA) measuring using microparticle RIA and CMIA(Architect i2000SR) / use the CLIA(DXI-800) method to compare and evaluate the correlation between the tests in the same test items. Materials and Methods Commissioned from January 2014 to March 2015 patients were enrolled in a total of 273 people. 29 out of 273 people conducted by RIA were compared with CMIA, 244 patients were compared with CLIA. Using reagents and equipment were used RIA(Diasource), CMIA(Architect i2000SR, Abbott Diagnostics) / CLIA( Unicel DXi-800, Beckman coulter). Results Correlation of the RIA and CLIA was a R2 = 0.1844 (y = 0.7303x + 3.9005), and the correlation of RIA CMIA is R2 = 0.2762 (y = 0.8862x + 4.56) respectively. (According to statistics, during the same period RIA is Deficiency 4.31%, Insufficiency 90.53%, Sufficiency 5.16%, was Excess 0%, CLIA / CMIA is Deficiency 17.02%, Insufficiency 75.91%, Sufficiency 7.03%, indicating the distribution of 0.03 % Excess) Conclusion Serum vitamin D and parathyroid hormone that show an inverse relationship, the level above which are not parathyroid hormone and vitamin D reduced the increase. The density is different for each study, at most 20 is reported to be the maximum between 30 ng / ml. In Korea it requires a proposed standard of vitamin D deficiency, reference to the WHO lack the case more than 10ng/ml, 20ng/ml and defined by the lack of, if not more than, the IOM, but looking at 12ng/ml or less to the normal to lack, at least 20ng/ml, the reference do not match the deficit under 20ng/ml, 21-29ng/ml relative lack between, was also defined as a sufficient condition for more than 30ng/ml. Although not statistically is between RIA and CLIA two ways to vitamin D levels change according to season match, when seasonally seen in summer as commonly known (April to September), winter (October to March) relative to the increase measured than it was found. Finally, the study on the correlation between the two methods have been expected to result in a consistent and apply the same view high reference value on the graph is difficult. However, there may be differences between the test equipment and methods, and could be especially the case of RIA method using an organic solvent is difficult to compare different methods and correlated view similar trend in vitamin D deficiency and quarterly aspect ratio.

  • PDF

Complications and Carcinogenic Effects of Mustard Gas - a Systematic Review and Meta-Analysis in Iran

  • Panahi, Yunes;Gholami, Nasrin;Ghojazadeh, Morteza;Moslemi, Farnaz;Naghavi-Behzad, Mohammad;Azami-Aghdash, Saber;Ghaffari, Alireza;Piri, Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7567-7573
    • /
    • 2015
  • Background: Catastrophic effects of mustard gas as a chemical warfare agent have always been a major problem for those exposed to this agent. In this meta-analysis it was tried to evaluate carcinogenesis, ocular, cutaneous and respiratory complications of mustard gas exposure among Iranians who had been exposed to this agent during the Iran-Iraq war. Materials and Methods: In this meta-analysis, the required data were collected using keywords "mustard gas", "sulfur mustard", "cancer", "neoplasm", "respiratory complications", "ocular complications", "lung disease", "chronic complication", "eye", "skin", "cutaneous complication", "carcinogenesis" and their combination with keywords "Iran", "Iranian", "prevalence", "mortality" and their Farsi equivalent terms from the databases of SID, Iranmedex, Magiran, Pubmed, Science Direct, Google Search engine, Gray Literature and Reference of References. To determine the prevalence of each complication and perform meta-analysis, CMA: 2 (Comprehensive Meta-Analysis) software with a randomized model was used. Results: Of the 542 articles found, 7 national articles, consistent with the aims of this study were selected. Meta-analysis of seven papers revealed that cancer risk, especially cancer of the respiratory system was elevated, so that the relative risk (RR) of cancer role of mustard gas was inconsistent from 2/1 to 4 in this survey. Also prevalence of delayed skin disorders due to sulfur mustard was 94.6%, pulmonary complications 94.5% and ocular complications 89.9%. The incidence of various cancers in victims exposed to mustard gas was 1.7% worldwide where the rate was 2.2% in Iranian victims of the Iraq-Iran war. Conclusions: Based on present study the prevalence of delayed mustard gas related cutaneous, pulmonary and ocular complications is above 90% and risk of carcinogenesis is higher in comparison to worldwide statistics. This may suggest need for long-term and persistent follow-up and rehabilitation procedures for populations exposed to this agent.

Display of Irradiation Location of Ultrasonic Beauty Device Using AR Scheme (증강현실 기법을 이용한 초음파 미용기의 조사 위치 표시)

  • Kang, Moon-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.25-31
    • /
    • 2020
  • In this study, for the safe use of a portable ultrasonic skin-beauty device, an android app was developed to show the irradiation locations of focused ultrasound to a user through augmented reality (AR) and enable stable self-surgery. The utility of the app was assessed through testing. While the user is making a facial treatment with the beauty device, the user's face and the ultrasonic irradiation location on the face are detected in real-time with a smart-phone camera. The irradiation location is then indicated on the face image and shown to the user so that excessive ultrasound is not irradiated to the same area during treatment. To this end, ML-Kit is used to detect the user's face landmarks in real-time, and they are compared with a reference face model to estimate the pose of the face, such as rotation and movement. After mounting a LED on the ultrasonic irradiation part of the device and operating the LED during irradiation, the LED light was searched to find the position of the ultrasonic irradiation on the smart-phone screen, and the irradiation position was registered and displayed on the face image based on the estimated face pose. Each task performed in the app was implemented through the thread and the timer, and all tasks were executed within 75 ms. The test results showed that the time taken to register and display 120 ultrasound irradiation positions was less than 25ms, and the display accuracy was within 20mm when the face did not rotate significantly.

A Case Report for a Korean Patient with Mucopolysaccharidosis IIIA Confirmed by Biochemical and Molecular Genetic Investigation (생화학적 검사 및 분자유전학적 검사에 의해 뮤코다당증 제3A형으로 진단된 한국인 환자의 증례 보고)

  • Kim, Borahm;Cho, Sung Yoon;Sohn, Young Bae;Park, Hyung-Doo;Lee, Soo-Youn;Song, Junghan;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.1
    • /
    • pp.44-48
    • /
    • 2015
  • Mucopolysaccharidosis (MPS) IIIA is a lysosomal storage disorder caused by abnormalities of the enzyme Heparan N-sulfatase that is required for degradation of heparan sulfate. The patient in this study was a 5 year-old boy who presented with macrocephaly and developmental delay. Urinary excretion of glycosaminoglycan was increased (26 g/moL creatinine, reference range: <7 g/moL creatinine) and a distinct band of heparan sulfate was shown in electrophoresis. Heparan N-sulfatase activity was significantly decreased in skin fibroblasts (0.2 pmoL/min/mg protein, reference range: 9-64 pmoL/min/mg protein). PCR and direct sequencing analysis of the SGSH gene showed compound heterozygous mutations: c.1040C>T (p.S347F) and c.703G>A (p.D235N). This is the first report for a Korean patient with MPS IIIA who was confirmed by biochemical investigation and molecular genetic analyses.

Characteristic Evaluation of Exposed Dose with NORM added Consumer Product based on ICRP Reference Phantom (ICRP 기준팬텀 기반의 천연방사성핵종이 포함된 가공제품 사용으로 인한 피폭선량 특성 평가)

  • Yoo, Do Hyeon;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.159-167
    • /
    • 2014
  • In Korea, July 2012, the law as called 'Act on Safety Control of Radioactive Rays Around Living Environment' was implemented to control the consumer product containing Naturally Occurring Radioactive Material (NORM), but, there are no appropriate database and effective dose calculation system. The aim of this study was to develop evaluation technique of the exposure dose with the use of the consumer products containing NORM and to understand the characteristics of the exposed dose according to the radiation type and energy. For the evaluate of exposure dose, the ICRP reference phantom was simulated by the MCNPX code based on Monte Carlo method, and the minimum, medium, maximum energy of alphas, betas, gammas from the representative NORM of Uranium decay series were used as the source term in the simulation. The annual effective doses were calculated by the exposure scenario of the consumer product usage time and position. Short range of the alpha and beta rays are mostly delivered the dose to the skin. On the other hand, the gamma rays mostly delivered the similar dose to all of the organs. The results of the annual effective dose with $1Bq{\cdot}g^{-1}$ radioactive stone-bed and 10% radioactive concentration were employed with the usage time of 7 hours 50 minute per day, the maximum annual effective dose of alphas, betas, gammas were calculated 0.0222, 0.0836, $0.0101mSv{\cdot}y^{-1}$, respectively.

The Study on Curriculum of the Departments Related to Make-up in Korean Colleges

  • Kim, Eun-Sil
    • Journal of Fashion Business
    • /
    • v.15 no.6
    • /
    • pp.113-133
    • /
    • 2011
  • The purpose of this study is to establish academic identity as well as produce human resources that industries need by grasping curriculum of the departments related beauty focusing on Korean colleges (junior colleges and four year course colleges), analyzing examples of advanced countries and suggesting their developmental direction. For the research method, the reference period of curriculum in Korean colleges was from Jul. 05th, 2011 to Aug. 05th, 2011. the investigation method is as follow: first, the curriculum of the departments related to beauty which were registered in the web sites were investigated. Second, the documents were received by fax and Email from each department after calling it. Third, questions and answers were done in reference to majors on the phones. these methods are intended for 65 junior colleges and 16 four year course colleges (total 81 ones). It clarified that lifelong education centers and the graduate courses were ruled out. the statistical analysis about data which were investigated like this were done by the frequency analysis. The results which examined the major subjects of Make-up focusing on Korea and foreign countries are as follow: First, the result which examined the major and theory subjects of Make-up has found that there are the human body theory, the equipment theory, the marketing theory are the management theory in Korean junior colleges and physiology/chemical, management, marketing and equipment product were treated in four year course colleges of Korea. As for foreign colleges, the subjects related to history and culture are mainly treated as the theory courses and their purpose is to cultivate basic knowledge of the fields which are mainly connected to Make-up including plays, movies, TV and studios. Second, the result which examined practice subjects of Make-up major has found that practice subjects of the total ones are of great importance in junior colleges. And it could be found that the Make-up field is of little importance as it is not independent and exists with the hair and skin fields in one department in the four year course colleges. Especially, in the foreign countries, the more detailed and professional subjects including classes which treat digital media, studio technologies, production, wigs and the special effects were treated by the field class system and these characteristics implies that Korean curriculum should be changed in the future. Based on this analytical results of investigation, this researcher tried to propose the developmental direction of Korean curriculum in the future.

Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea (심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가)

  • Kim, Jung-Su;Lee, Joun-Hyuk;Jung, Hae-Kyoung;Kim, Jung-Min;Cho, Byung Ryul
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • The use of cardiac angiography (CA) and the interventional procedures is rapidly increasing due to the increase in modern adult diseases. Cardiovascular intervention (CI) is an examination method where radiation is applied to the same area for a long period, and thus may cause skin injury. In this study, we investigate the diagnostic reference level (DRL) of the cardiovascular intervention (CI) carried out by medical institutions and use it as a tool to reduce patient exposure dose. In this study, the DRL was set by acquiring information about the cumulative fluoroscopy time, cumulative fluoroscopy dose-area product (DAP), radiography DAP, cumulative DAP, air kerma, number of video clips, and the total number of images from the cardiac angiography and interventional procedures performed on 147 patients. The DAPs corresponding to the DRL of cardiac angiography(CA) and that of the interventional procedures were shown to be $44.4Gy{\cdot}cm2$ and $298.6Gy{\cdot}cm2$, respectively; the corresponding DRLs of fluoroscopy time were shown to be 191.5s and 1935.3s, respectively. A DRL is not a strict upper bound for radiation exposure. However, the process of setting, enacting, and reviewing the DRLs for the dose by medical institutions will contribute to a reduction in the unnecessary exposure dose of patients.