• Title/Summary/Keyword: Skin reference

Search Result 211, Processing Time 0.025 seconds

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

Facial region Extraction using Skin-color reference map and Motion Information (칼라 참조 맵과 움직임 정보를 이용한 얼굴영역 추출)

  • 이병석;이동규;이두수
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.139-142
    • /
    • 2001
  • This paper presents a highly fast and accurate facial region extraction method by using the skin-color-reference map and motion information. First, we construct the robust skin-color-reference map and eliminate the background in image by this map. Additionally, we use the motion information for accurate and fast detection of facial region in image sequences. Then we further apply region growing in the remaining areas with the aid of proposed criteria. The simulation results show the improvement in execution time and accurate detection.

  • PDF

Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance (기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

Design of myoelectrical sensor for myoelectric hand prosthesis (전동의수용 근전위 센서 설계)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.247-249
    • /
    • 2007
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60㎐ power-line noise, amplifier, and a level circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

  • PDF

Willingness to pay for eco-friendly products: case of cosmetics

  • Joung, Soon Hee;Park, Sun Wook;Ko, Yoon Jin
    • Asia Marketing Journal
    • /
    • v.15 no.4
    • /
    • pp.33-49
    • /
    • 2014
  • Environmental concern has been an important issue for a few decades, and the extent of consumer demand for eco-friendly consumption has been increased. This study seeks to investigate consumers' willingness to pay (WTP) a premium for eco-friendly cosmetics. This study evaluates how much more a consumer is willing to pay for eco-friendly cosmetics and examines significant factors influencing consumers' WTP for eco-friendly cosmetics. Consumers' WTP is measured using four different ecofriendly cosmetics: low-priced skin care cosmetics, low-priced makeup cosmetics, high-priced skin care cosmetics, and high-priced makeup cosmetics. This study uses the contingent valuation method (CVM) to estimate consumer's WTP for eco-friendly cosmetics. Survey questions were designed using both dichotomous choice and payment card method of CVM. Through face to face interviews and on-line surveys, the data were collected from women between 20 and 49 years old residing in Seoul and Kyeonggi area, Korea, in May 2010. A total of 226 questionnaires (132 from interviews and 94 from on-line) were included for the analytical sample in this study. The data were analyzed using descriptive analysis, T-test and Log-Logit analysis. The findings are as follows: First, the WTP measured by dichotomous choice method was estimated using the Log-Logit analysis. The results showed that the estimated WTP for low-priced skin care cosmetics was 19,152 won, which was 27.7% higher than the reference price, 15,000 won. For low-priced makeup cosmetics, the estimated WTP was 18,524 won, and its green premium was 21.0%. The estimated WTP for high-priced skin care cosmetics was 59,128 won, which was 18.3% higher than the reference price, 50,000 won. For high-priced makeup cosmetics was 57,666 won, and its green premium was 15.3%. Second, the WTP measure by payment card method was estimated using descriptive analysis. The results showed that the respondents were willing to pay 17,955 won for low-priced skin care cosmetics, which was 19.7% higher than the reference price, 15,000 won and 17,595 won for low-priced makeup cosmetics, which was 17.3% higher than the reference price. For high-priced skin care cosmetics, the average WTP was 56,950 won which was 13.9% higher than the reference price, 50,000 won. For high-priced makeup cosmetics, the average WTP was 55,650 won, which was 11.3% higher than the reference price. Overall, the WTP was higher in order of low-priced skin care, low-priced makeup, high-priced skin care, and high-priced makeup. It means that consumers decide degree of premium based on the price and the attributes of eco-friendly products. Third, the findings showed that age, monthly income, and having children or not were statistically significant factors that influenced consumers' willingness to pay for eco-friendly cosmetics. Other explanatory variables such as education, marital status, job, purchase experience of eco-friendly products, and environmental concerns did not show any statistical significance. The major contribution of this study is the investigation of the value of green attributes of the products by using CVM. Unlike most previous researches, this research used two methods of CVM, the dichotomous choice and the payment card, so it enhanced the reliability of research. According to this study, consumers showed price sensitivity when they pay green premium. These findings can be used as useful information to establish marketing strategies for green cosmetics.

  • PDF

Implications of using a 50-μm-thick skin target layer in skin dose coefficient calculation for photons, protons, and helium ions

  • Yeom, Yeon Soo;Nguyen, Thang Tat;Choi, Chansoo;Han, Min Cheol;Lee, Hanjin;Han, Haegin;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1495-1504
    • /
    • 2017
  • In a previous study, a set of polygon-mesh (PM)-based skin models including a $50-{\mu}m-thick$ radiosensitive target layer were constructed and used to calculate skin dose coefficients (DCs) for idealized external beams of electrons. The results showed that the calculated skin DCs were significantly different from the International Commission on Radiological Protection (ICRP) Publication 116 skin DCs calculated using voxel-type ICRP reference phantoms that do not include the thin target layer. The difference was as large as 7,700 times for electron energies less than 1 MeV, which raises a significant issue that should be addressed subsequently. In the present study, therefore, as an extension of the initial, previous study, skin DCs for three other particles (photons, protons, and helium ions) were calculated by using the PM-based skin models and the calculated values were compared with the ICRP-116 skin DCs. The analysis of our results showed that for the photon exposures, the calculated values were generally in good agreement with the ICRP-116 values. For the charged particles, by contrast, there was a significant difference between the PM-model-calculated skin DCs and the ICRP-116 values. Specifically, the ICRP-116 skin DCs were smaller than those calculated by the PM models-which is to say that they were under-estimated-by up to ~16 times for both protons and helium ions. These differences in skin dose also significantly affected the calculation of the effective dose (E) values, which is reasonable, considering that the skin dose is the major factor determining effective dose calculation for charged particles. The results of the current study generally show that the ICRP-116 DCs for skin dose and effective dose are not reliable for charged particles.

Studies on Epizootic Skin Diseases of Swine in Korea with Special Reference to Etiology of Parakeratosis (Parakeratosis를 중심으로 한 돈의 유행성피부질병에 관한 연구)

  • Lee Hyun Beom
    • Journal of the korean veterinary medical association
    • /
    • v.16 no.3
    • /
    • pp.129-136
    • /
    • 1980
  • Present experiments were conducted to classify the epizootic skin diseases of swine and determine the etiological agent of swine parakeratosis in Korea. Twnty-three herds of swine with skin disease in Gyongbug prefecture were examined clinicopathologicall

  • PDF

Skin color reappearance for color enhancement in TV (TV의 색 향상을 위한 살색 재현)

  • 이응주;이광춘;하영호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.38-45
    • /
    • 1997
  • Skin color reappearance problem in color processing system is necessary to transform a specific color sand improve color reappearance quality as a reference color. The skin color has been situated as an important memory color not only in our lives but also in color application systems such as TV. Thus, skin color reappearance problem is more important than other color processing problem. In this paper, we propose a skin color reappearance algorithm for color enhancement in TV which use phase detector to detect the skin colors at real-time from 3.58 MHz color burst signal and color signal, comparators to discriminate the types of skin color, and micom to reprodece standard skin colors for races.

  • PDF

Histopathology of dermatitis verrucosa in holstein dairy cattle (홀스타인 젖소의 우상피부염 (dermatitis verrucosa) 의 병리조직)

  • Jean, Young-Hwa;Kim, Jae-Hoon;Jeong, Soon-Wuk;Yoon, Suk-Jung;Choi, Sang-Ho
    • Korean Journal of Veterinary Pathology
    • /
    • v.3 no.1
    • /
    • pp.65-68
    • /
    • 1999
  • Clinically, three holstein dairy cattle showed the inappetence and decrease of milk production with severe lameness and pain. Grossly, strawberry-like proliferation of the skin between the heel bulbs were observed 4${\times}$5${\times}$1.5cm in size. Histopathologically, severe hyperplasia of epidermis, parakeratotic hyperkeratosis and multifocal ulceration of cornified cell layer, acanthosis, spongiosis of prickle cell layer and irregular arrangement of basal cell layer were seen. And focally observed the lesions of necrotic vasculitis, infiltration of inflammatory cells, congestion and hemorrhage. Spirochete bacteria were found in necrotic and outer proliferated epidermal cells by Levaditi's silver stain. Clinical and pathological findings were consistent with dermatitis verrucosa.

  • PDF

Human Dermal Risk Assessment on Chlorpyrifos of Korean Farmers (우리나라 농민의 Chlorpyrifos에 대한 피부 위해성 평가)

  • 정경미;이효민;이은희;이선희;김진화;심영용;홍진태;이용욱
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.3
    • /
    • pp.187-198
    • /
    • 2002
  • Chlorpyrifos is an organophosphate insecticide and one of the most commonly and widely used insecticide. However, a little known about the dermal risk of chlorpyrifos on human being. Therefore, this study was conducted for the dermal risk assessment after exposure to chlorpyrifos in Korean farmers. First, skin irritation by chlorpyrifos (10 mg/$\textrm{cm}^2$, 50 mg/$\textrm{cm}^2$, 100 mg/$\textrm{cm}^2$, 250 mg/$\textrm{cm}^2$ in acetone) was determined in rabbits for 5 days considering the usage of chlorpyrifos short term highly exposure. The index of skin irritation by chlorpyrifos was increased in each dose and length of exposure dependent manners. Next, using benchmark dose (BMD$_{5}$) approach, the dose-response relationship was assessed to calculate the reference dose (RfD). The value of RfD was 2.84 $\mu\textrm{g}$/kg/day from 142.16 $\mu\textrm{g}$/kg/day BMD5 value divided uncertainty factor 50. Finally, we assessed human dermal risk of chlorpyrifos with exposure level and RfD. Skin absorbed levels were assumed with several exposure scenarios encounting the circumstances of exposure that application method, protection equipment and cloth, exposure time and exposure frequency during chlorpyrifos spraying. By the comparison of skin absorbed dose with the reference dose, it was identified that risk values (risk index) to skin chlorpyrifos exposure were 0.958 from the point of above results and it was recommended that the occurrence of hazard effect (skin irritation toxicity) of chlorpyrifos would not be expected. Risk index was smaller than 1 in the case of spraying vehicle mounted application, 1hour exposure time and wearing protective cloth exposure. Whereas, risk index was above 1 in the case of hand-held application, 2hour exposure time and wearing common cloth. Comparing two kinds of application method, total risk index of the hand held application (1.67) was higher than vehicle mounted (0.27). Therefore, chlorpyrifos skin exposure was mainly affected by application equipment and applied form. The results of risk assessment on the human dermal toxicity of chlorpyrifos should be required to control in keeping safety rules, skin surface area available for contact, spraying time ,and spraying frequency.y.

  • PDF