• 제목/요약/키워드: Skin equivalent

Search Result 139, Processing Time 0.024 seconds

Investigation of Cell Size Effects of Honeycomb Sandwich Composite Square Tubes Under Compressive Loadings (허니콤 샌드위치 복합소재 정사각 튜브의 셀 크기에 따른 압축거동평가)

  • Kim, Jung-Seok;Yoon, Hyuk-Jin;Kwon, Tae-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • The objective of this study is to evaluate effects of honeycomb cell size for compressive behaviors of square sandwich composite tubes with woven fabric carbon/epoxy skin and Al honeycomb core. In order to achieve these goals, four different kinds of tubes were fabricated and compressed to 200mm~250mm under quasi-static load of 10mm/min. The Al honeycombs with cell size of 6.35mm and 9.53mm were used. The relationship of mean compressive load and cell size was evaluated. In addition, the effect of peel strength and equivalent elastic modulus in ribbon direction for the mean compressive load was investigated.

Effects of Foot Reflexo-massage on Physical, Psychological, Physiological Parameters in Patients with Osteoarthritis (발반사마사지가 골관절염 환자의 신체적, 심리적, 생리적 지수에 미치는 영향)

  • Uhm, Dong-choon
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.2
    • /
    • pp.276-287
    • /
    • 2004
  • Purpose: This study was undertaken to investigate the effects of foot reflexo-massage on physical, psychological, and physiological parameters in patients with osteoarthritis of the knee. Method: This study was employed non-equivalent control group pretest-posttest time series experimental design. The subjects of this study were 47 elderly patients with osteoarthritis of the knee from two different nursing homes in Deajeon. The patients were divided into two groups; 26 patients in experimental group, the rest in control group. Each patient in experimental group received the 30-minute foot reflexo-massage, 3 times per week for 4 weeks. The dependent variables of each patient were measured before treatment, after 2 weeks and after 4 weeks during the treatment session. The collected data was analyzed using the Social Package Social Science(version 10.0) software program. Result: There were significant differences in the flexion angle of both knees; the flexion and extension muscle strength of both knees; systolic blood pressure; POMS; plantaris skin temperature and blood velocity of dorsalis pedis artery between the two groups over different the three measurement times. Conclusion: The results suggest that foot reflexo-massage could be an effective intervention to improve physical, psychological and physiological parameters for patients with knee osteoarthritis.

  • PDF

Effects of Qi Hand Reflexology on Autonomic Nervous System Activity and Physical Resistance to Stress in Inpatients (기 손 반사요법이 입원환자의 자율신경계 활성도와 스트레스 저항도에 미치는 영향)

  • Oh, Sei-Young;Park, Ok-Soon;Woo, Myung-Yi
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.4
    • /
    • pp.531-538
    • /
    • 2010
  • Purpose: This study was done to identify the effects of Qi hand reflexology on autonomic nerve activity in patients admitted to hospital. Method: A non-equivalent control group and quasi-experimental research with pre/post test design were used and 59 patients on a medical ward were assigned to either the experimental group (32) or the control group (27). The study variables included vital signs, autonomic nerve activities (ALF (absolute low frequency), AHF (absolute high frequency), nLF (normalized low frequency), nHF (normalized high frequency), SDNN (standard deviation of all normal-normal intervals)) and were evaluated using the QECG-3 system. The experimental group was treated with Qi hand reflexology for 10 minutes per day, for 3days. Results: Skin temperature and systolic blood pressure in the experimental decreased with treatment. ALF, AHF and SDNN for the experimental group increased with regulating proportion (nLF: nHF=6:4) and a significant difference between the groups was observed. Conclusion: The results indicated that application of Qi hand reflexology for patients in the hospital is effective in regulating the autonomic nervous system activation. Implication of finding should be useful for future research.

TA Study on Patient Exposure Dose Used the Phantom for Interventional Procedure (중재적 시술 시 팬텀을 이용한 환자의 피폭선량 분석)

  • Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.71-76
    • /
    • 2011
  • Because interventional procedure operates looking at premier as real time when perate intervention enemy, by patient is revealed during suitableness time in radiation, side effect such as radiation injury of skin is apt to happen. It established by purpose of study that measure exposure dose that patient receives about these problem, and find solution for radiation injury and repletion method. In this study, we used Rando phantom of identical structure with the human body which becomes accomplished with 4 branch ingredient of the attempt and system equivalent material them and absorbed dose were measured by TLD. According to the laboratory, it shows that operations such as TFCA procedure or uterine myoma embolization are more dangerous than TACE procedure. If both operations are inspected during a short time, it is not affected in being bombed. However, it can lead to palliative agenesis or depilate, definitive agenesis only if operations are repeated more than three times. Dose distibution based on experiment, to reduce radiation exposure to patients result from reduction of scatter ray as we control field size of radiation and protection of side organs except for tumor. also we knew that we can protect patients form radiation exposure, if we increas SOD and decrease SID.

  • PDF

Effects of a Finger Guard while Opening the Glass Ampoule by Nursing Students (손가락보호대의 적용이 간호대학생의 유리앰플 개봉 시 찔림사고, 불안 및 사용자만족도에 미치는 효과)

  • Lee, Jung-Ok
    • Journal of Korean Biological Nursing Science
    • /
    • v.21 no.4
    • /
    • pp.318-325
    • /
    • 2019
  • Purpose: The purpose of this study was to identify the effects of a finger guard developed to prevent sharp injuries in nursing students. Methods: This study was an equivalent control group posttest design. Seventy nursing students were randomly allocated to either the experimental group (n= 35) or the control group (n= 35). The finger guard was used whileopening the glass ampoule in the experimental group. The outcome variables such as sharp injuries, anxiety and user satisfaction were measured. Results: Sharp injuries were 0 in the experimental group and 2 in the control group (p= .160). Anxiety in the experimental group was significantly lower than the control group (p< .001). User satisfaction was 4.33 score in the range from 1 to 5, the highest item was the weight (4.63), followed by effectiveness (4.51). Conclusion: Using a protective device while opening the glass ampoule was observed to be effective in reducing anxiety among the nursing students, and exhibited protection of skin.

A Study on the Hooting of Aluminum Sheet by Full-Bridge Resonant Inverter (풀브리지 공진형 인버터를 이용한 알루미늄 박판가열에 관한 연구)

  • Shin, Dae-Chul;Kim, Sung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.56-61
    • /
    • 2005
  • The induction heating is widely used not only in the industrial fields but also in the home appliances. But the conventional induction heating systems have shortcoming that it use only magnetic utensil, in this paper, heating of Aluminum sheet by full-bridge series resonant high-frequency inverter is proposed. Also, the principle of induction heating and operations of full-bridge inverter equivalent circuit are explained. The proposed inverter controls the output voltage using phase-shift irrespective of the switching frequency using phase-shift. As a result the proposed induction heating system by full-bridge resonant inverter shows the possibility that make up for the shortcoming of the conventional existing induction heating systems.

Loss and Efficiency Dependence of a 6.78 MHz, 100 W, 30 cm Distance Wireless Power Transfer System on Cable Types (6.78 MHz, 100 W, 30 cm 거리 무선 전력 전송 시스템의 전선별 손실 및 효율 비교)

  • Lee, Seung-Hwan;Lee, Byung-Song;Jung, Shin-Myung;Park, Chan-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1651-1657
    • /
    • 2015
  • In MHz operating wireless power transfer systems, skin- and proximity-effect losses in the transmitter and the receiver coils dominate the coil-to-coil efficiency of the system. A Litz-wire was regarded as a common solution for minimizing such Ohmic losses in high frequencies. In this paper, equivalent series resistances of 12 different cables including Litz-wire and copper tubing have been calculated and measured for a 6.78 MHz, 100W, 30 cm wireless power transfer system. It has been shown that the copper tubing has lower resistances compared to the Litz-wire in that frequency and a wireless power transfer system with the copper tubing was able to achieve much higher efficiency than a system using the Litz-wire. Calculations of the resistances and efficiencies were accomplished with analytical equations and those calculations were evaluated by experimental results.

Uni-axial behaviour of normal-strength CFDST columns with external steel rings

  • Dong, C.X.;Ho, J.C.M.
    • Steel and Composite Structures
    • /
    • v.13 no.6
    • /
    • pp.587-606
    • /
    • 2012
  • Concrete-filled-steel-tubular (CFST) columns have been well proven to improve effectively the strength, stiffness and ductility of concrete members. However, the central part of concrete in CFST columns is not fully utilised under uni-axial compression, bending and torsion. It has small contribution to both flexural and torsion strength, while it can be replaced effectively by steel with smaller area to give similar load-carrying capacity. Also, the confining pressure in CFST columns builds up slowly because the initial elastic dilation of concrete is small before micro-crackings of concrete are developed. From these observations, it is convinced that the central concrete can be effectively replaced by another hollow steel tube with smaller area to form double-skinned concrete-filled-steel-tubular (CFDST) columns. In this study, a series of uni-axial compression tests were carried out on CFDST and CFST columns with and without external steel rings. From the test results, it was observed that on average that the stiffness and elastic strength of CFDST columns are about 25.8% and 33.4% respectively larger than CFST columns with similar equivalent area. The averaged axial load-carrying capacity of CFDST columns is 7.8% higher than CFST columns. Lastly, a theoretical model that takes into account the confining effects of steel tube and external rings for predicting the uni-axial load-carrying capacity of CFDST columns is developed.

Effects of Auriculotherapy on Sleep Disorders in the Elderly (수면장애 노인에 대한 귀자극요법의 적용효과)

  • Lee, Jae-On;Kwon, Young-Sook
    • Journal of East-West Nursing Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: This study was conducted to investigate the effects of auriculotherapy on sleep disorders in the elderly. Methods: The study was a quasi-experimental design with a non-equivalent control group pre-post post-test. The participants were 43 elderly, members of community senior centers, experimental group were 23 elderly, and control group were 20 elderly. For the experimental group, small seeds (semen vaccaria) were applied to five locations of both auricular skin surfaces: shen men, heart, anterior lobe, occiput, and spleen of posterior surface. The seeds were applied every week, and remained in surfaces for 5 days. The procedure were repeated 4 times. The control group was not treated. The collected data were statistically processed using SPSS 12.0 version and the data was analyzed for descriptive statistics and t-test. Results: The experimental group had a greater improvement in sleep scale score (t=-4.717, p<.001) and sleep satisfaction score (t=-6.095, p<.001) as compared to the control group. Conclusions: Auriculotherapy by small seeds (semen vaccaria) is effective in allaying sleep disorders in the elderly. The results may be useful to community health nurses.

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.