• Title/Summary/Keyword: SizeKorea

Search Result 26,154, Processing Time 0.043 seconds

Size Effect on Axial Compressive Strength of Notched Concrete Specimens (노치가 있는 콘크리트 실험체의 축압축 강도에 대한 크기효과)

  • 이성태;김봉준;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.99-108
    • /
    • 2000
  • The size effect on axial compressive strength in notched concrete specimens was experimentally investigated. Based on the concept of the fracture mechanics and size effect law, theoretical studies for axial compressive failure of concrete were reviewed, and two failure modes of concrete specimens under compression were discussed. In this study, experiments of axial compressive failure, which is one of the two failure modes, was carried out by using cylindrical specimens. Adequate notch length was taken from the experimental result of strength variation based on the notch length. And, by taking various sizes of specimens the size effect on axial compressive strength of concrete was investigated. Also, model equations were suggested by modified size effect law (MSEL). The test results show that size effect appears conspicuously for all series of specimens. Additionally, the effect of initial notch length on axial compressive strength was also apparent.

The Picking Lead Time for the Picking Batch Size in a Warehouse System (창고시스템에서 인출 배치크기에 대해 인출소요시간)

  • Chang, Suk Hwa
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.2
    • /
    • pp.17-24
    • /
    • 2013
  • This paper is to analyze the picking lead time for picking batch size in a warehouse system and to get minimum picking batch size that is the warehouse system feasible. The warehouse system consists of aisles and racks, which two racks face each other through aisle. The products are picked from the storage locations by batch size. The probability that items are picked in the each row of the rack in the aisle for order picking activity is derived. The picking lead time for picking batch size is the time passed from the first picking location to arrival at starting location in aisle picking all items included in a batch size. The picking lead time for picking batch size in an aisle is analyzed. The picking lead time for picking batch size in the whole warehouse system is obtained. The warehouse system is feasible if all items that customers order are picked from the storage locations for same period. The picking batch size that is the warehouse system feasible is obtained. The problem is analyzed, a solution procedure is developed, and a numerical example is shown to explain the problem.

A Standard Size System of Combat Boots (전투화 표준규격 시스템에 관한 연구)

  • Yun Deok-Gyun;Gang Hyeon-Sun
    • Journal of the military operations research society of Korea
    • /
    • v.12 no.2
    • /
    • pp.56-67
    • /
    • 1986
  • This paper is concerned with a standard size system and production proportion of combat boots. For the standard size system foot sizes of 327 soldiers were mesured by Martin type anthropometric equipment. 24 foot measurements were obtained on all individuals. The standard size system of which key measurements are foot length and joint girth are proposed on the basis of the statistically treated measurement data. The production (or purchasing) proportion of the proposed size system of combat boots are also proposed.

  • PDF

A Study on the Determination of Optimal Lot Size in Distribution System (물류시스템에서의 최적 로트크기 결정원칙에 관한 연구)

  • 김상직;김영식;김영겸
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.35
    • /
    • pp.39-46
    • /
    • 1995
  • This study is to find the optimal lot size method in the distribution system. In general, the lot size methods used in the distribution system is the same as the methods of the MRP system. The lot size methods used in this study are LFL, EoQ, LTC and POQ.. Resulting in case study, LTC is the optimal lot size method in the distribution system. In distribution system, VRP and VSP shall be investgated.

  • PDF

Highly Ordered Porous Silica Adsorbent with Dual Pore Size Regime for Bulky VOC Gas Sensing

  • Yun, Ji Sun;Jeong, Young Hun;Nam, Joong-Hee;Cho, Jeong-Ho;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.181-184
    • /
    • 2013
  • Highly ordered porous materials having mesopores in the walls of macropores showed improved adsorption dynamics results for VOC molecules, especially bulky molecules. These meso/macroporous mataerials were synthesized by the dual templating method, and mesopore and macropore size were controlled by adjusting the templates for each pore size regime. In the case of adsorption and desorption of small VOC molecules (toluene), although meso/macroporous MCM-41 with smaller mesopore size showed improved results, meso/macroporous SBA-15 with larger mesopore size was not improved regardless of the existence of macropores, since there was no limitation of movement through the larger mesopore. However, the adsorption dynamics of bulky VOC molecules (p-xylene) over meso/macroporous SBA-15 were drastically improved by increasing the macropore size.

Association of Endocrine Factors (Insulin-Like Growth Factor-II and Binding Protein-3) with Litter Size in Pigs

  • Yun, J.S.;Kang, W.J.;Seo, D.S.;Park, S.S.;Hong, K.C.;Lee, C.Y.;Ko, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.3
    • /
    • pp.307-315
    • /
    • 2001
  • Litter size has been one of the important economic traits in porcine reproduction. The insulin-like growth factor (IGF) system has been shown to mediate actions of the steroid hormone or to synergize with other endocrine factors so that it consequently plays roles in reproductive processes, including ovulation, implantation, maintenance of pregnancy, and fetal development. However, the effect of the serum IGF system on porcine litter size has not been deeply studied. Therefore, this study was conducted to relate serum IFG-II concentration and IGF binding protein-3 (IGFBP-3) expression with porcine litter size. Moreover, the possible association of those with estrogen receptor (ER) as a candidate gene for litter size was investigated. Swine were separated into two groups showing high and low litter sizes, and sera were collected from sows in the estrous cycle to postnatal growth of their female progeny. Serum IFG-II concentration was measured by radioimmunoassay and IGFBP-3 expression was detected by Western ligand blotting. During the estrous cycle, IGFBP-3 expression in both groups decreased moderately from metestrus to estrus, but IFG-II concentration showed a reverse pattern. Also, IFG-II concentration and IGFBP-3 expression decreased gradually as pregnancy proceeded. Unlike IGFBP-3, IFG-II decreased moderately as newborn pigs grew. Significant differences in serum IFG-II amount between the two groups were detected at 60 (p<0.01), 75, 90, and 105 d (p<0.05) of pregnancy and at 60 (p<0.01), 45, and 105 d (p<0.05) of postnatal growth. Furthermore, based on ER genotypes, a high litter size group with genotypes AB and BB showed lower IFG-II concentration than a low litter size group with a genotype AA during pregnancy. Taken together, the results indicate that the serum IFG-II and IGFBP-3 are correlated with the litter size in pigs.

Experimental Investigation of Coupling Effects between Particle Size and Temperature on the Thermal Conductivity of Alumina Nanofluids

  • Lee, Ji-Hwan;Jang, Seok Pil;Lee, Seung-Hyun;Park, Yong-Jun;Kim, Dong Jin;Koo, Jaye
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.174-181
    • /
    • 2014
  • This study investigates the effects of nanoparticle size and temperature on the thermal conductivity enhancement of water-based alumina ($Al_2O_3$) nanofluids, using the centrifuging method and relative centrifugal forces of differing magnitude to produce nanofluids of three different particles without involving any dispersants or surfactants. We determined the coupling dependency in thermal conductivity enhancement relative to nanoparticle size and temperature of the alumina nanofluids and also experimentally showed that the effect of temperature on thermal conductivity is strongly dependent on nanoparticle size. Also, our experimental data presented that the effective medium theory models such as the Maxwell model and Hasselman and Johnson model are not sufficient to explain the thermal conductivity of nanofluids since they cannot account for the temperature- and size-dependent nature of water-based alumina nanofluids.

Morphological, Physical Characterization of Poly(acrylic acid) Nanogel Prepared by Electron Beam Irradiation

  • Park, Jong-Seok;Choi, Jong-Bae;Gwon, Hui-Jeong;Lim, Youn-Mook;Jeong, Sung-In;Shin, Young-Min;Kang, Phil-Hyun;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • Nanogels are internally cross-linked particles of sub-micrometer size made of hydrophilic polymers and are considered a distinct type of macromolecules, compared with linear and branched polymers or macroscopic gels. In this study, we studied a method of radiation induced synthesis of nanogels, which allows us to obtain tailored intra-molecularly crosslinked macromolecules of independently chosen molecular weight and dimensions. Thus, we report the possibility of applying the prepared nanogels using poly(acrylic acid) through electron beam irradiation for potential application as biomaterials. The nanogels were characterized by scanning electron microscopy (SEM). In addition, the size and zeta-potential of nanogels were measured by a particle size analyzer (PSA). The nanogels were prepared at an approximate size of 180 nm at 100 kGy and were spherical in shapes. The size of the nanogels decreased with increasing irradiation doses, and the absolute value of zeta potential increased with increasing irradiation doses.

Interpretation of Morphology and Rubber-Phase Particle Size Distribution of High Impact Polystyrene (내충격성 폴리스티렌의 형태구조 및 고무상 입도분포 해석)

  • 정한균;정대원;안경현;이승종;이성재
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.744-753
    • /
    • 2001
  • One of the most important factors which affect the impact strength of high impact polystyrene (HIPS) is the rubber-phase particle size and size distribution. In this study, HIPS was prepared from a batch reactor to observe the influence of reaction conditions such as rubber content, agitation speed and prepolymerization time on the particle size and size distribution. Measurements concerning the particle size distribution were conducted using a particle size analyzer. Due to swelling, the particle suspended in toluene increases in size with lower heat-treatment temperature and shorter heat-treatment time, while the particle in methyl ethyl ketone shows quite reasonable size without any effort of heat-treatment. As rubber content increases, the average particle size increases substantially, but the increase in agitation speed at lower rubber contents does not have much influence on the size. However, the polystyrene-phase particles occluded in rubber-phase become more uniform as agitation speed increases. Longer prepolymerization time produces rubber-phase particles with narrower particle size distribution.

  • PDF

Calculation of Sample Size in Clinical Trials (임상 연구에서 연구 표본수의 산출)

  • Lee, Hyo-Jin;Kim, Yang-Soo;Park, In
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.53-57
    • /
    • 2013
  • Purpose: This review aims to explain the definition and basic principle of statistical analysis and to clarify statistical issues related to the sample size calculation. Materials and Methods: Many formulas are available that can be applied for different types of data and study design. Results: The sample size is the number of patients or other experimental units that need to be calculated prior to the study. Determining the appropriate sample size is required to answer the research question. Conclusion: Caution is needed when applying formula for the calculation of the sample size, as it is sensitive to error and even small differences in selected parameters can lead to large differences in the sample size.