• Title/Summary/Keyword: Size distribution measurement

Search Result 516, Processing Time 0.03 seconds

The Study of Measurement Method for an electrodeless lamp (무전극 램프의 광특성 측정방식에 대한 고찰)

  • Lee, Se-Hyun;Cho, Mee-Ryoung;Shin, Sang-Wuk;Hwang, Myung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.68-71
    • /
    • 2003
  • In this paper, We have investigated the luminous flux, luminous efficacy, spectral energy distribution, colour rendering index, correlated colour temperature of electrodeless QL lamp system as a center method of measurement and side method of measurement. A result of measurement is that center method of measurement and side method of measurement is almost similar. Therefore, Sample that didn't measured because of big size and heavy weight can be measured by center method of measurement.

  • PDF

The Measurement Methods of a Large Light Source Using the Integrating Sphere (적분구를 이용한 대형광원의 측정방법)

  • Hwang, Myung-Keun;Lee, Se-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.585-587
    • /
    • 2005
  • In this paper, We studied two methods to measure optical characteristics of an electrodeless light source using the integrating sphere(diameter 1.5m). One is to use a center measurement method and the other is to use a side measurement method. As a result of analysis, a side measurement methode without auxiliary lamp is almost similar against a center measurement with auxiliary lamp to reduce a measurement of an error for luminous flux, luminous efficacy and spectral distribution etc. Therefore, Sample which cannot measured by reason of big size and heavy weight can be measured by a side measurement method.

Spray characteristics of twin-fluid atomization using external-mixing sonic nozzles (외부혼합형 음속노즐을 사용한 2유체 미립화의 분무특성)

  • Park, Byeong-Gyu;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.132-139
    • /
    • 1997
  • Spray characteristics of external mixing sonic twin-fluid atomization nozzles are investigated experimentally. Particle sizes are measured by the Fraunhofer diffraction method using the Malvern particle analyzer, and their radial distributions are obtained using the tomographical transformation technique. The spatial distribution of SMD shows that the drop size increases in the radial direction at a fixed liquid flow rate, and the distribution is getting uniform rapidly as the atomizing gas pressure increases. The SMD decreases as the liquid flow rate increases at a fixed GLR. It is found that the atomization efficiency of the flush type sonic nozzle is superior to that of protrusion type. The effect of laser beam diameter of the particle analyzer on the spatial SMD distribution is minor at present experimental conditions.

Effect of Contact Statistics on Electrical Contact Resistance (전기접촉저항에 관한 접촉통계치의 영향)

  • Jang, Yong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1080-1085
    • /
    • 2003
  • The flow of electrical current through a microscopic actual contact spot between two conductors is influenced by the flow through adjacent contact spots. A smoothed version of this interaction effect is developed and used to predict the contact resistance when the statistical size and spatial distribution of contact spots is known. To illustrate the use of the method, an idealized fractal rough surface is defined using the random midpoint displacement algorithm and the size distribution of contact spots is assumed to be given by the intersection of this surface with a constant height plane. With these assumptions, it is shown that including finer scale detail in the fractal surface, equivalent to reducing the sampling length in the measurement of the surface, causes the predicted resistance to approach the perfect contact limit.

  • PDF

Brassiere sizing system applying loss function -Centering on elderly women- (손실함수를 이용한 브래지어 치수 규격 설정에 관한 연구)

  • 이경화;최혜선
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.268-279
    • /
    • 1995
  • The purpose of this study is to suggest a brassiere sizing chart for elderly women. It is found that there is no direct linear relationship between cup size and under bust girth from the analsis of breast measurements. These 2 factors(under bust girth and cup size) were chosen as 2 axes of brassiere size chart. A loss function was used to determined intervals of bust girth and cup size of size chart, because the loss function introduces the concept of frequency to size chart for better customer's satisfaction. From the dual distribution table whose intervals had been determinde by a loss function. The 15 sizes, which had more than 2% of appearance were suggested for brassiere size chart. The suggested brassierc sizes covened 87.6% of all subjects. Considering that KS brassiere size thart consisting of 32 sizes covers 88.5%, the suggested brassiere size chart would be considered quite feasible. Also is suggested supply reference measurement chart relevant to brassiere manufacturing for 10 most frequent sizes.

  • PDF

Manufacture of paste opaque porcelains using glycols as a solvent and evaluation of their physical properties (글리콜을 용매로 제조한 연고형 불투명 도재의 물성)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.41-62
    • /
    • 2003
  • In this research, we manufactured the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent, and compared the composition of solvents, the coefficient of thermal expansion, the particle size distribution, the viscosity and bonding strength to metal, and the tone with those of the commercial products(Duceram Plus, Duceram GmbH; VMK 95, Vita Co.; Noritake EX-3, Noritake Co.)used in the clinical field. The results of the research were as follows: 1. The result of solvent analysis indicated that the solvents included in the paste opaque porcelains of the control group were mainly composed of Glycols. 2. From the Coefficient of thermal expansion measurement, we drew out the following results; testing group: $14.0\times10^{-6}/^{\circ}C$, Duceram Plus: $13.9\times10^{-6}/^{\circ}C$, VMK 95: $14.3\times10^{-6}/^{\circ}C$, and Noritake EX-3: $13.3\times10^{-6}/^{\circ}C$. 3. Seen from the result of particle size distribution measurement, the experimental group was similar to the control group in 1$\mu m$ below, but the experimental group marked the highest distribution of 61% in the case of between 1$\mu m$ and 5$\mu m$. Between 5$\mu m$ and 10$\mu m$, they showed relatively similar distribution, and Noritake EX-3 was turned out the highest distribution of 29% in 10$\mu m$ above. 4. From the result of viscosity measurement, Duceram plus showed the highest viscosity throughout all the measurements followed by Noritake Ex-3, experimental group and VMK 95 in decreasing order. 5. The result of bonding strength measurement was EX 35.53 $\beta\acute{A}$, DU 40.88 $\beta\acute{A}$, VM 39.43 $\beta\acute{A}$, and NO 35.39 $\beta\acute{A}$, and no significant difference was found between the experimental group and the control groups(P>0.05). 6. The measurement of the tone indicated that the $L^*$ value of the experimental group was 86.89 0.63 in average, which is higher than the control group in its brightness. In the case of the $a^*$ value, Duceram Plus, VMK 95 and EX-3 showed positive value, whereas the testing group was turned out negative value. In $b^*$ value, Duceram Plus proved the highest. From the results of this research, the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent did not make differences from the commercial products that are actually used in the clinical fields. Therefore, it is possible to utilize Propylene Glycol (PG) and Buthylene Glycol (BG) for the paste opaque porcelains of P.F.M crown. It is also recommended that further researches concerning the compositions and forms of powder, the types of organic solvent components and the ratio of mixture proceeded in order to improve the level of productivity in the future.

  • PDF

Measurement of Porosity by EPMA-EDS Image Processing

  • Hung, Minhui;Li, Xiangting;Xia, Jiyu;Ding, Chuanxian
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.66-69
    • /
    • 1997
  • Porosity is one important characteristic feature and structural index of sprayed coatings. A method of measurement of porosity, EPMA-EDS image processing is developed in the paper. The characteristics of pores can be determined by processing of the image obtained from an electron microscope via VISTA, Not only the porosity can be presented but also the statistical result of pore size distribution. Finally it can be drawn from this paper that EPMA-EDS is a quite effective method to completely characterize the pores in plasma sprayed coatings.

  • PDF

Point Cloud Measurement Using Improved Variance Focus Measure Operator

  • Yeni Li;Liang Hou;Yun Chen;Shaoqi Huang
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.170-182
    • /
    • 2024
  • The dimensional accuracy and consistency of a dual oil circuit centrifugal fuel nozzle are important for fuel distribution and combustion efficiency in an engine combustion chamber. A point cloud measurement method was proposed to solve the geometric accuracy detection problem for the fuel nozzle. An improved variance focus measure operator was used to extract the depth point cloud. Compared with other traditional sharpness evaluation functions, the improved operator can generate the best evaluation curve, and has the least noise and the shortest calculation time. The experimental results of point cloud slicing measurement show that the best window size is 24 × 24 pixels. In the height measurement experiment of the standard sample block, the relative error is 2.32%, and in the fuel nozzle cone angle measurement experiment, the relative error is 2.46%, which can meet the high precision requirements of a dual oil circuit centrifugal fuel nozzle.

Characteristics of the Droplet Behavior in the Overlap Region of Twin Spray and in Single Spray (이중분무의 중첩영역과 단일분무에서 액적의 거동 특성)

  • Jung, Ji-Won;Cha, Keun-Jong;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1300-1308
    • /
    • 2000
  • The objectives of this study was to investigate the spray characteristics of single spray and twin spray in the overlap region such as mean axial velocity, mean radial velocity, mean droplet size and probability density function of droplet size. A phase doppler anemometer was used as the measurement system for droplet size and velocity. In case of single spray, injection pressure was varied from 0.2MPa to 0.7MPa. Mean axial velocity, mean radial velocity and droplet size were decreased as the distance below nozzle tip was increased. In case of twin spray, the spray characteristics were measured by varying the distance between two nozzles from 127mm to 155mm. In the overlap region, the boundary of the overlap region was determined by obtaining the distribution of mean axial and radial velocity. Droplet size was increased as the distance from nozzle tip was increased. It was found that the distribution of droplet size for twin spray in the overlap region was different to single spray.

A Study on the Simultaneous Measurement of Droplet Size and Velocity in a Diesel Fuel Spray (디젤 분무(噴霧) 액적(液滴)의 크기와 속도(速度) 동시계측(同時計測)에 관한 연구(硏究))

  • Chang, Y.J.;Jeon, C.H.;Park, H.l.;Kim, H.K.;Kim, S.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.5
    • /
    • pp.11-22
    • /
    • 1994
  • The pupose of this study is to measure droplet size and velocity simultaneously for a transient diesel fuel spray in a quiescent chamber at atmospheric temperature and pressure. Generally, diesel combustion phenomena is mainly governed by characteristics of injection system and fuel spray. Therefore we need to clarify these characteristics for developing more economical diesel systems. In this study, correlation between droplet size and velocity was measured at downstream distance from nozzle. Governing parameters are pump speed and fuel quantity for the detailed nature in this transient diesel fuel spray. It is observed effect to the droplet size and velocity distribution. Velocity(peak, mean, rms), number density and droplet size were investigated simulaneously using PDA in the spray. Various results are presented to illustrate the effects of operation factors and correlation between the droplet diameter and velocity.

  • PDF