• 제목/요약/키워드: Size Bias

검색결과 492건 처리시간 0.035초

Domain formation characteristics during thermomagnetic recording for amorphous TbFe and TbFeCo alloy thin films

  • Kim, Soon-Gwang
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.235-241
    • /
    • 1989
  • Static according tests were carried out on a series of amorphous TbFe thin films of various composition under a constant laser irradiation condition. Examination of recorded domain configurations by using polarizing microscope led to the categorization of domain characteristics into 3 distinctly different types; i.c., type A: circular domains with smooth boundaries, the size not sensitive to variation of bias field, type B: domains of irregular shape at low bias, the size increasing and the boundaries getting smoother and more circular with increasing bias field and type C: not recordable. Critical factor which distinguishes among each types was fond to be the relative magnitude of H and H of the film near T, regardless of constituent atomic species. Micromagnetical process of thermomagnetic recording cycle was analyzed scheniatically for each type.

  • PDF

비특이적 만성 허리통증 환자에 대한 전기자극의 효과 : 국내 데이터베이스의 메타분석 (Effects of Electrical Stimulation on Patients with Non-Specific Low Back Pain : A Meta-Analysis of Domestic Database)

  • 이정우;조성현
    • 대한통합의학회지
    • /
    • 제10권3호
    • /
    • pp.37-52
    • /
    • 2022
  • Purpose : The purpose of this meta-analysis was to evaluate the effects of electrical stimulation on patients with non-specific low back pain. Methods : Domestic databases were gathered from studies that conducted clinical trials associated with electrical stimulation and its impact on pain of non-specific low back patients. A total of 681 studies were identified, with 12 studies satisfying the inclusion data. The studies consisted of patient, intervention, comparison, outcome, and study design (PICO-SD). The search outcomes were items associated with low back pain. Cochrane risk of bias 2 (RoB 2) was used to evaluate the quality of 12 randomized controlled trials. Effect sizes (Hedges's g) in this study were computed as the corrected standard mean difference (SMD). A random-effect model was used to analyze the effect size because of the high heterogeneity among the studies. Egger's regression and 'trim-and-fill' tests were carried out to analyze the publication bias. Cumulative meta-analysis and sensitivity analysis were conducted to analyze the effect according to the sample size and the consistency of the effect size. Results : The following factors had a large overall effect size (Hedges's g=1.28, 95 % CI=.20~2.36) involving electrical stimulation on non-specific low back pain. The subgroup analysis all showed a statistical difference in the types of study design, electrical stimulation, and assessment tool. No statistically significant difference was found in the meta-regression analysis. Publican bias was found in the data. Conclusion : The findings in this study indicate that electrical stimulation interventions have a positive effect on patients with non-specific low back pain. However, due to the low quality of studies and publication bias, the results of our study should be interpreted cautiously.

Optimal designs for small Poisson regression experiments using second-order asymptotic

  • Mansour, S. Mehr;Niaparast, M.
    • Communications for Statistical Applications and Methods
    • /
    • 제26권6호
    • /
    • pp.527-538
    • /
    • 2019
  • This paper considers the issue of obtaining the optimal design in Poisson regression model when the sample size is small. Poisson regression model is widely used for the analysis of count data. Asymptotic theory provides the basis for making inference on the parameters in this model. However, for small size experiments, asymptotic approximations, such as unbiasedness, may not be valid. Therefore, first, we employ the second order expansion of the bias of the maximum likelihood estimator (MLE) and derive the mean square error (MSE) of MLE to measure the quality of an estimator. We then define DM-optimality criterion, which is based on a function of the MSE. This criterion is applied to obtain locally optimal designs for small size experiments. The effect of sample size on the obtained designs are shown. We also obtain locally DM-optimal designs for some special cases of the model.

인구 집단의 스케일의 확장이 집단 비율 및 집단 크기 지각에 미치는 영향: 다수편향적 사회적 정보 활용을 중심으로 (On the Effect of Extended Human Group Scale in Perception of Group Ratio and Size at Majority-biased Social Learning)

  • 장재경 ;장대익
    • 인지과학
    • /
    • 제34권1호
    • /
    • pp.39-66
    • /
    • 2023
  • 뉴미디어는 사회적 교류의 장을 인터넷으로 옮겨와 대규모 집단이 시공간의 한계를 뛰어넘어 한 곳에서 소통할 수 있게 만들었다. 최근 연구는 인간의 사회적 능력이 소셜 미디어를 통해 경험하는 확장된 집단 스케일을 따라가지 못하는 사례를 보고하기도 한다. 이러한 맥락에서, 본 연구는 인간의 사회적 정보 지각이 인구 집단 스케일의 확장에 영향을 받는지 다수편향 맥락에서 확인하였다. 인터넷 기반 과제를 통해 구성원의 수로 나타낸 집단 크기와 전체에서 특정 집단이 차지하는 집단 비율이 개인에게 지각되고 다수편향적 사회적 정보 활용에 영향을 주는 심리적 과정을 조사하였으며, 전체 집단 스케일의 확장에 각 과정이 영향을 받는지 살펴보았다. 집단 비율은 다수편향에 정적 영향을 주고 있으며, 그 관계는 비율 지각에 의해 부분매개 되었다. 전체 집단 스케일은 집단 비율과 비율 지각의 관계를 조절하지 않았다. 반면, 집단 크기와 다수편향의 상관은 유의하지 않았다. 전체 집단 스케일은 집단 크기 지각을 조절하였다. 전체 집단 스케일이 작은 조건에서 집단 크기와 크기 지각은 양적 상관을 나타냈지만, 전체 집단의 스케일이 확장된 조건에서 지각된 집단 크기는 유의미하게 작아졌고, 두 변수는 상관을 잃었다. 이러한 결과를 통해 집단 크기 지각과 관련된 심리 기제가 전체 집단 스케일의 확장에 제대로 반응하지 못하고 있음을 확인하였다. 나아가 집단 크기 정보를 처리하는 전문화된 심리 기제가 존재할 가능성과 다수편향이 특이적으로 받아들이는 자극의 형태를 진화심리적 관점에서 논하였다.

전처리조건과 기판Bias가 MPECVD 다이아몬드 박막의 특성에 미치는 영향 (Effects of Pretreatment Condition and Substrate Bias on the Characteristics of MPECVD Diamond Thin Films)

  • 최지환;박정일;박광자;이은아;장감용;박종완
    • 한국표면공학회지
    • /
    • 제28권4호
    • /
    • pp.225-235
    • /
    • 1995
  • To investigate the effects of pretreatment and substrate bias on the characteristics of the diamond thin films, the thin films were deposited on the p-type Si(100) wafer by MPECVD using mixtures of $H_2$, $CH_4$, and $O_2$ gases. Deposition was carried out at the substrate temperature of $900^{\circ}C$ and at the pressure of 40torr. The effect of the pretreatment on the film formation was the examined by using SiC and diamond powders as abrasive powders. Furthermore, the substrate bias effect on the formation of the diamond film was also examined. The highest nucleation density was observed for the pretreatment with 40~60$\mu\textrm{m}$ size of diamond powders and a negative bias potential(-50V). Many defects and(111) twins in the diamond films were observed.

  • PDF

Effects of preselection of genotyped animals on reliability and bias of genomic prediction in dairy cattle

  • Togashi, Kenji;Adachi, Kazunori;Kurogi, Kazuhito;Yasumori, Takanori;Tokunaka, Kouichi;Ogino, Atsushi;Miyazaki, Yoshiyuki;Watanabe, Toshio;Takahashi, Tsutomu;Moribe, Kimihiro
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권2호
    • /
    • pp.159-169
    • /
    • 2019
  • Objective: Models for genomic selection assume that the reference population is an unselected population. However, in practice, genotyped individuals, such as progeny-tested bulls, are highly selected, and the reference population is created after preselection. In dairy cattle, the intensity of selection is higher in males than in females, suggesting that cows can be added to the reference population with less bias and loss of accuracy. The objective is to develop formulas applied to any genomic prediction studies or practice with preselected animals as reference population. Methods: We developed formulas for calculating the reliability and bias of genomically enhanced breeding values (GEBV) in the reference population where individuals are preselected on estimated breeding values. Based on the formulas presented, deterministic simulation was conducted by varying heritability, preselection percentage, and the reference population size. Results: The number of bulls equal to a cow regarding the reliability of GEBV was expressed through a simple formula for the reference population consisting of preselected animals. The bull population was vastly superior to the cow population regarding the reliability of GEBV for low-heritability traits. However, the superiority of reliability from the bull reference population over the cow population decreased as heritability increased. Bias was greater for bulls than cows. Bias and reduction in reliability of GEBV due to preselection was alleviated by expanding reference population. Conclusion: Cows are easier in expanding reference population size compared with bulls and alleviate bias and reduction in reliability of GEBV of bulls which are highly preselected than cows by expanding the cow reference population.

BDI의 변동성 추정: 레버리지 GARCH 모형을 중심으로 (Estimation of BDI Volatility: Leverage GARCH Models)

  • 모수원;이광배
    • 한국항만경제학회지
    • /
    • 제30권3호
    • /
    • pp.1-14
    • /
    • 2014
  • BDI건화물운임지수의 변동성은 환율과 주가의 변동성을 크게 초과할 정도로 대단히 클 뿐만 아니라 변동성이 점차 커지고 있어서 운임을 예측하는데 많은 어려움을 겪고 있다. 이에 본고는 이러한 운임지수의 변동성을 정확히 포착할 수 있는 모형을 찾는데 목적을 둔다. 이를 위해 변동성 분석에 흔히 사용되는 대칭형 변동성 모형인 GARCH 모형과 비대칭 변동성 모형인 AGARCH모형, GJR모형, EGARCH모형을 도입한다. 그것은 나쁜 뉴스가 좋은 뉴스보다 더 큰 변동성을 야기할 가능성이 높기 때문이다. 먼저 운임의 예측불가능요소를 운임의 요일별 특성을 제거한 후 자기회귀를 하여 구한 후 GARCH 분석을 적용하는데 적합한 성격을 갖는가를 조사한다. 비대칭모형의 AGARCH모형에서는 비대칭을 나타내는 계수가 유의하나 부호가 모형의 예상과 달라 나쁜 뉴스가 좋은 뉴스보다 더 큰 변동성을 야기하지 않으며, EGARCH모형의 비대칭계수도 양의 부호로 모형의 예상과 반대일 뿐만 아니라 유의하지 않아 나쁜 뉴스가 좋은 뉴스보다 더 큰 변동성을 야기하지 않는다는 것, 그리고 GJR모형에서도 해당 계수가 음으로 모형과 반대로 유의하지 않아 음의 충격이 양의 충격보다 더 큰 변동성을 유발하지 않음을 보인다. 이에 따라 BDI건화물운임지수의 변동성은 GARCH모형을 이용하는 것이 합리적이라는 점을 보인다.

초고주파 집적회로의 수율향상을 위한 새로운 바이어스 안정화 회로 (A Newly Proposed Bias Stability Circuit for MMIC율s Yield Improvement)

  • 권태운;신상문;최재하
    • 한국전자파학회논문지
    • /
    • 제13권9호
    • /
    • pp.882-888
    • /
    • 2002
  • 본 논문에서는 공정변화와 온도변화에 의한 MMIC의 성능저하를 보상할 수 있는 바이어스 안정화 회로를 제안하였다. 제안된 바이어스 안정화 회로는 기존의 정전류원을 사용하는 바이어스 회로와의 비교를 통하여 그 효과를 검증하였다. 두 구조를 동일한 조건으로 비교하기 위해 하나의 레이아웃에 두 구조를 채택한 증폭기를 동시에 설계 및 제작을 하였다. 공정오차는 세가지 경우 NOM, MIM, MAX로 구분하고 각각에 대해 고주파 특성을 측정하였다. 측정 결과로 정전류원을 가지는 바이어스회로를 채택한 증폭기 의 1.8 GHz에서의 이득변화는 6.4 dB, Ids 변화 7 mA이지만 제안된 바이어스회로를 채택한 증폭기는 이득변화는 2.1 dB, Ids 변화 3 mA로 우수한 특성을 보임을 확인하였다. 따라서, 제안된 바이어스 회로를 적용한 MMIC는 공정상의 변화와 온도 등에 의한 동작점의 변화를 보상하여 고주파특성의 감쇠를 보상할 수 있고 궁극적으로 회로의 수율을 개선할 수 있다. 제작된 회로의 전체크기는 1.2 mm $\times$ 1.4 mm이다.

Effect of Substrate Bias Voltage on the Growth of Chromium Nitride Films

  • Jang, Ho-Sang;Kim, Yu-Sung;Lee, Jin-Hee;Chun, Hui-Gon;You, Yong-Zoo;Kim, Dae-Il
    • 한국재료학회지
    • /
    • 제17권11호
    • /
    • pp.618-621
    • /
    • 2007
  • Chromium nitride (CrN) films were deposited on silicon substrate by RF magnetron sputtering assisted by inductive coupled nitrogen plasma without intentional substrate heating. Films were deposited with different levels of bombarding energy by nitrogen ions $(N^+)$ to investigate the influence of substrate bias voltage $(V_b)$ on the growth of CrN thin films. XRD spectra showed that the crystallographic structure of CrN films was strongly affected by substrate bias voltage. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) results showed that surface roughness and grain size of the CrN films varied significantly with bias voltage. For - 80 $V_b$ depositions, the CrN films showed bigger grain sizes than those of other bias voltage conditions. The lowest surface roughness of 0.15 nm was obtained from the CrN films deposited at .130 $V_b$.

코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구 (A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge)

  • 이주상;김신도;김광영
    • 환경위생공학
    • /
    • 제10권2호
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF