• 제목/요약/키워드: Six switches

검색결과 28건 처리시간 0.025초

Analytic Model of Four-switch Inverter-fed Driving System for Wye or Delta-connected Motor with Current Ripple Reduction Scheme

  • Lee, Dong-Myung;Jung, Jin-Woo;Heo, Seo Weon;Kim, Tae Heoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.109-116
    • /
    • 2016
  • This paper proposes an analytic model for four-switch inverter (FSI)-driven wye (Y) or delta (Δ)-connected motors with a current ripple reduction algorithm. FSIs employ four switches in controlling three-phase load instead of using six switches. They have split dc-link stage, and due to this inherent structure there exists the voltage difference between upper and lower capacitors, which results in distortion of the inverter output voltage. To study characteristics of FSIs, this paper presents an advanced simulation models of FSI-driven control system for 3-phase motor that can has a wire connection either Y or Δ. In addition, this paper introduces a current ripple reduction scheme that mitigates degradation of control performance due to the voltage difference between the dc-link capacitors. The validity of the proposed method and the analytic model is verified by simulations and experiments carried out with 1-HP induction machine with Y or Δ-connection

국내 배편계통의 최적 연계(안) (The Optimal Number of Dividing and Connecting Per Feeder in Korea Distribution System)

  • 조남훈;김건중;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권7호
    • /
    • pp.349-361
    • /
    • 2002
  • Occasionally, equipment in a distribution system fails due to damage from weather, vandalism, or other causes. Failures and unexpected events do not always occur as and where expected. Therefore, a good contingency plan, multi-zone or otherwise, provides flexibility by locating switches at various strategic locations so that parts of a feeder can be picked up in the event of line outages at various places. It is possible to create feeder system layout that achieve remarkable contingency support economics, even as their normal peak loading levels approach thermal capacity, by utilizing six, seven, or even nine switchable zones per feeder. But many switchable zones per feeder are of questionable practicality and effectiveness, because of the complexity and time required for the switching operation. In practice, a zonal scheme with between three and four zones will usually provide complete contingency backup for all feeders. Line switches have both capital and maintenance costs, the planning for multi-zonal schemes is considerably more difficult than or loop or single-zone systems, and the required switching operations required during contingencies take more time. But multi-zonal schemes are used because these costs come to far less than the cost of additional capacity required for loop or single-zone. In this paper, we present the optimal number of switchable zones per feeder in Kora distribution system.

An Optimized PI Controller Design for Three Phase PFC Converters Based on Multi-Objective Chaotic Particle Swarm Optimization

  • Guo, Xin;Ren, Hai-Peng;Liu, Ding
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.610-620
    • /
    • 2016
  • The compound active clamp zero voltage soft switching (CACZVS) three-phase power factor correction (PFC) converter has many advantages, such as high efficiency, high power factor, bi-directional energy flow, and soft switching of all the switches. Triple closed-loop PI controllers are used for the three-phase power factor correction converter. The control objectives of the converter include a fast transient response, high accuracy, and unity power factor. There are six parameters of the controllers that need to be tuned in order to obtain multi-objective optimization. However, six of the parameters are mutually dependent for the objectives. This is beyond the scope of the traditional experience based PI parameters tuning method. In this paper, an improved chaotic particle swarm optimization (CPSO) method has been proposed to optimize the controller parameters. In the proposed method, multi-dimensional chaotic sequences generated by spatiotemporal chaos map are used as initial particles to get a better initial distribution and to avoid local minimums. Pareto optimal solutions are also used to avoid the weight selection difficulty of the multi-objectives. Simulation and experiment results show the effectiveness and superiority of the proposed method.

새로운 컨버터 토폴로지에 의한 스위치드 리럭턴스 모터의 구동에 관한 연구 (A study on the Switched Reluctance Motor drive by a New Converter Topology)

  • 강욱;김학성;류홍제;원충연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.459-461
    • /
    • 1994
  • This paper proposed a new converter topology improving the split source type converter. In this converter. two switches and six diodes add to the split source type converter. The proposed converter has a performance minimized a negative torqe, putting a phase current off by double impressed voltage 2Vdc. Hence, a new converter results in increase of the average output power and improves converter efficiency in heavy load and high speed. Theoretical prediction is verified by experimental results got with a new proposed converter and 8/6 poles SRM.

  • PDF

스위치드 리럭턴스 전동기 구동을 위한 새로운 컨버터에 관한 연구 (A study on the new converter for the switched reluctance motor drive)

  • 강욱;원충연
    • 전자공학회논문지B
    • /
    • 제33B권2호
    • /
    • pp.217-226
    • /
    • 1996
  • Switched reluctance motor (SRM) drives appear today as viable alternatives to induction and brushless motor drives in a wide range of application such as machine tools, fans, and pumps. This paper deals with a new converter topology which can be used in order converter. The split source type converter consists of minimum switching devices to be used in switched reluctance motor (SRM) drive. In this proposed converter two switches and six diodes are added to split source type converter. The proposed converter has performance minimizes the negative torque, Which puts the phase current off by double impressed voltages. The major advangtage of this converter is the increase of the average output power while improving better converter efficiency in heavy load and high speed than other topologies. The proposed converter system has been implemented using 80C196KB microcontroller and experiments were carried out ot verify the simulation results.

  • PDF

유도 전동기 구동용 다이오드 브릿지-타입 ZVT 인버터 (A Diode Bridge-type ZVT Inverter for Induction Motor Drive Application)

  • 이성룡;고성훈;권순신;송인석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.295-298
    • /
    • 1999
  • In this paper, the diode bridge-type ZVT(Zero-Voltage Transition) inverter is proposed. It consists of one auxiliary switch, three resonant inductors and six blocking diodes. So, the advantage of the proposed topology is the reduction of the auxiliary switch. The topology of the proposed ZVT inverter is analyzed with a description of the control conditions based on the load current. Therefore, this paper two control algorithms were discussed. A variable resonant pattern control algorithm by using load current feedback and a resonant period control algorithm by using resonant inductor current feedback is proposed in order to achieve the ZVT switching condition in full control range and the reducing current spike main switches cause by reverse recovery problem.

  • PDF

Novel Three-Phase PWM Voltage-Fed Rectifier with an Auxiliary Resonant Commutated Pole Link

  • Qu, Ke-Qing;Zhao, Jin-Bin
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.678-686
    • /
    • 2014
  • A novel auxiliary resonant commutated pole (ARCP) link for three-phase PWM voltage-fed converter is presented. The ARCP link consists of two auxiliary switches, one resonant inductance, and six diodes, which is simpler than the conventional ARCP designs. Based on the phase and amplitude control, the proposed converter can take a minimum switching times PWM method, which results in reduced losses and a simplified control. In addition, the zero-voltage resonance modes are analyzed. Finally, simulation and experimental results show that the system can realize zero-voltage switching with a unity power factor.

국산 배전자동화시스템 구성설비의 보유기능 및 특성 (The Functions and Characteristics of Distribution Automation System Components)

  • 하복남;박상만;장정태;최태일;김호용;오상기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터 (Low-Cost Single-Phase to Three-Phase PWM Converters for Induction Motor Drives)

  • 김태윤;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.201-204
    • /
    • 2001
  • In this paper, a single-phase to three-phase PWM converter topology using six switches only for low cost induction motor drive is proposed. The converter topology is of lower cost than the conventional one, which gives sinusoidal input current, unity power factor, dc output voltage control and bidirectional power flow In addition, the source voltage sensor is eliminated by controlling the deviation between the model current and the system current to be zero. The performance of the proposed converter has been demonstrated through the computer simulation.

  • PDF

스위치 저감형 풀브리지 컨버터의 구조 및 병렬 운전 기법에 관한 연구 (Interleaved Phase Shifted Full Bridge Converter using Six Switches)

  • 이제현;이승운;김두호;조보형;김우섭;이재호;양천석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.199-200
    • /
    • 2012
  • 본 논문에서는 저전압 대전류 출력 구조에 적합한 병렬 운전형 풀브리지 컨버터의 구조 및 운전기법에 대하여 제안하였다. 제안된 회로에서는 6개의 스위치 및 위상각을 이용하여 풀브리지 컨버터 두 모듈의 병렬 운전이 가능하다. 2kW급 하드웨어를 통하여 제안된 회로의 기본 동작원리 및 실험결과를 기술하였다.

  • PDF