• 제목/요약/키워드: Six phase induction motor

검색결과 13건 처리시간 0.028초

Comparison of Efficiency for Different Switching Tables in Six-Phase Induction Motor DTC Drive

  • Taheri, Asghar;Rahmati, Abdolreza;Kaboli, Shahriyar
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, different switching tables proposed for the Direct Torque Controlled (DTC) of a six-phase induction machine are simulated and implemented. A six-phase induction motor has 64 space voltage vectors which result in increased complexity in the selecting of inverters switching. The unsuitable selection of a switching table leads to large harmonics especially at low speed and it also reduces drive efficiency. A six-phase induction machine has large zero sequence harmonic currents of the order $6{\kappa}{\pm}1$. These harmonic currents are varied in various techniques. Decreasing this loss is essential in a six-phase induction machine. The main purpose of this paper is to improve the ST-DTC of six-phase induction machines to reduce the voltage and current harmonics and the torque pulsation. Selecting a suitable method for minimizing these harmonics is very important.

Genetic Algorithm Based Design Optimization of a Six Phase Induction Motor

  • Fazlipour, Z.;Kianinezhad, R.;Razaz, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1007-1014
    • /
    • 2015
  • An optimally designed six-phase induction motor (6PIM) is compared with an initial design induction motor having the same ratings. The Genetic Algorithm (GA) method is used for optimization and multi objective function is considered. Comparison of the optimum design with the initial design reveals that better performance can be obtained by a simple optimization method. Also in this paper each design of 6PIM, is simulated by MAXWELL_2D. The obtained simulation results are compared in order to find the most suitable solution for the specified application, considering the influence of each design upon the motor performance. Construction a 6PIM based on the information obtained from GA method has been done. Quality parameters of the designed motors, such as: efficiency, power losses and power factor measured and optimal design has been evaluated. Laboratory tests have proven the correctness of optimal design.

임피던스 크기 비교를 통한 유도모터 턴쇼트 고장진단법 (Interturn Fault Diagnosis Method of Induction Motor by Impedance Magnitude Comparison)

  • 구본관;박준성;공태식;김태원;박태준
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.144-152
    • /
    • 2017
  • A motor model and off-line diagnosis method of the induction motor having an interturn fault(ITF) is studied. The proposed method is based on the magnitude comparison of the six impedance in the d-q plane. To prove the impedance unbalance, the induction motor model is presented with an ITF circuit loop with a fault resistance. Then, six impedance components in the stationary d-q plane are defined depending on the connected phase windings. Finding the maximum and minimum magnitude of the six impedance, the ITF and the faulty phase can be founded. To verify the proposed method, the experimental results with an induction motor having an ITF are shown.

Model Following Sliding-Mode Control of a Six-Phase Induction Motor Drive

  • Abjadi, Navid R.;Markadeh, Gholamreza Arab;Soltan, Jafar
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.694-701
    • /
    • 2010
  • In this paper an effective direct torque control (DTC) and stator flux control is developed for a quasi six-phase induction motor (QIM) drive with sinusoidally distributed windings. Combining sliding-mode (SM) control and adaptive input-output feedback linearization, a nonlinear controller is designed in the stationary reference frame, which is capable of tracking control of the stator flux and torque independently. The motor controllers are designed in order to track a desired second order linear reference model in spite of motor resistances mismatching. The effectiveness and capability of the proposed method is shown by practical results obtained for a QIM supplied from a voltage source inverter (VSI).

2상 유도전동기 구동 2상 인버터를 위한 새로운 PWM제어방식 II - 3-레그 타입의 경우 - (A Novel PWM Method for Three-Leg Two-Phase Inverter Fed Two-Phase Induction Motor)

  • 장도현
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.339-346
    • /
    • 2005
  • 본 논문에서는 3-레그 2상 인버터의 새로운 PWM방식을 제안하였다. 기존의 3-레그 인버터의 PWM방식은 전형적인 SVPWM 방식을 적용하여 PWM 방식이 복잡하다. 3-레그 2상 인버터를 "중성점이 있는 4-레그 인버터"의 등가회로라고 할 때 3-레그 인버터에서 형성되는 6개의 섹터는 4개의 섹터로 축소되며, 각 영역에서는 SYPWM 방식 대신 단순화된 정현파형 PWM방식을 적용할 수 있다. 각 레그의 스위치마다 스위칭 시간을 계산하는 스위칭 패턴을 제시하였다. 제안된 ,3-레그 인버터의 PWM방식에 대한 타당성을 확인하기 위해 모의 실험과 실험이 실행되었다.

A Six-Phase CRIM Driving CVT using Blend Modified Recurrent Gegenbauer OPNN Control

  • Lin, Chih-Hong
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1438-1454
    • /
    • 2016
  • Because the nonlinear and time-varying characteristics of continuously variable transmission (CVT) systems driven by means of a six-phase copper rotor induction motor (CRIM) are unconscious, the control performance obtained for classical linear controllers is disappointing, when compared to more complex, nonlinear control methods. A blend modified recurrent Gegenbauer orthogonal polynomial neural network (OPNN) control system which has the online learning capability to come back to a nonlinear time-varying system, was complied to overcome difficulty in the design of a linear controller for six-phase CRIM driving CVT systems with lumped nonlinear load disturbances. The blend modified recurrent Gegenbauer OPNN control system can carry out examiner control, modified recurrent Gegenbauer OPNN control, and reimbursed control. Additionally, the adaptation law of the online parameters in the modified recurrent Gegenbauer OPNN is established on the Lyapunov stability theorem. The use of an amended artificial bee colony (ABC) optimization technique brought about two optimal learning rates for the parameters, which helped reform convergence. Finally, a comparison of the experimental results of the present study with those of previous studies demonstrates the high control performance of the proposed control scheme.

유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터 (Low-Cost Single-Phase to Three-Phase PWM Converters for Induction Motor Drives)

  • 김태윤;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.201-204
    • /
    • 2001
  • In this paper, a single-phase to three-phase PWM converter topology using six switches only for low cost induction motor drive is proposed. The converter topology is of lower cost than the conventional one, which gives sinusoidal input current, unity power factor, dc output voltage control and bidirectional power flow In addition, the source voltage sensor is eliminated by controlling the deviation between the model current and the system current to be zero. The performance of the proposed converter has been demonstrated through the computer simulation.

  • PDF

Control Mode Switching of Induction Machine Drives between Vector Control and V/f Control in Overmodulation Range

  • Nguyen, Thanh Hai;Van, Tan Luong;Lee, Dong-Choon;Park, Joo-Hong;Hwang, Joon-Hyeon
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.846-855
    • /
    • 2011
  • This paper proposes a control mode switching scheme between vector control and constant V/f control for induction machine (IM) drives for maximum torque utilization in a higher speed region. For the constant V/f scheme, a smooth transition method from the linear range of PWM up to the six-step mode is applied, by which the machine flux and torque can be kept constant in a high-speed range. Also, a careful consideration of the initial phase angle of the voltage in the transient state of the control mode change between the vector control and V/f schemes is described. The validity of the proposed strategy is verified by the experiment result for a 3-kW induction motor drives.

스위치드 리럭턴스 전동기 구동을 위한 새로운 컨버터에 관한 연구 (A study on the new converter for the switched reluctance motor drive)

  • 강욱;원충연
    • 전자공학회논문지B
    • /
    • 제33B권2호
    • /
    • pp.217-226
    • /
    • 1996
  • Switched reluctance motor (SRM) drives appear today as viable alternatives to induction and brushless motor drives in a wide range of application such as machine tools, fans, and pumps. This paper deals with a new converter topology which can be used in order converter. The split source type converter consists of minimum switching devices to be used in switched reluctance motor (SRM) drive. In this proposed converter two switches and six diodes are added to split source type converter. The proposed converter has performance minimizes the negative torque, Which puts the phase current off by double impressed voltages. The major advangtage of this converter is the increase of the average output power while improving better converter efficiency in heavy load and high speed than other topologies. The proposed converter system has been implemented using 80C196KB microcontroller and experiments were carried out ot verify the simulation results.

  • PDF

멀티레벨 인버터와 다상 유도기를 이용한 견인기용 대전력 VSI의 구조와 특성 (Configurations of High Power VSI Drives for Traction Applications Using Multi Level Inverters and Multi Phase Induction Motors)

  • ;류홍제;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.500-504
    • /
    • 1997
  • Current source inverter drives of auto sequentially commutated type are very popular in high power applications, because of simple power circuit configuration with four quadrant operation. But the six-step current output create harmonic problems and the input power factor of such a drive is not always good. In this respect pulse width modulated drives using gate turn off thyristors ( GTO ) are finding application, especially in traction drives. However the switching and snubber loses of a GTO do not permit the inverter switching frequency go beyond a few hundred hertz.This will again introduce low frequency harmonic problems. Multi level inverters of the 3-level and 5-level can be considered as an alternative to overcome the low switching frequency harmonic problem of the 2-level GTO inverters. But with multi level inverters the complexity of the power circuit increases. In this paper a combination of multi level ( 2-level and 3-level ) inverters and multi phase induction motor ( 3-phase and 6-phase) configurations are presented for high power VSI drives for traction applications with reduced inverter switching frequency requirements coupled with reduced voltage rating for the power switch.

  • PDF