• Title/Summary/Keyword: Six Sigma in Korea

Search Result 204, Processing Time 0.021 seconds

Studies on the use of computer aided semen analysis(CASA) technology for fertility prediction in Korean native cattle (한우에서 Computer aided semen analysis(CASA) 기법을 이용한 수태율 예측에 관한 연구)

  • Lee, Kang-nam;Lee, Byeong-chun;Hwang, Woo-suk
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.882-897
    • /
    • 1998
  • This experiment was conducted to predict the effects of motional characteristics on the fertility of Korean native cattle(KNC) by using CASA technology and in vitro fertilization system. Twenty-six KNC frozen semen straws were obtained from Korean KNC improvement department, livestock improvement main division, national livestock cooperatives federation in Korea. Specimens were allowed to thaw at $37^{\circ}C$ for 30 sec in water bath. Semen analysis was performed on semen image analysis system(SIAS, Medical supply, Korea) adjusted to the gate settings and used the semen droplet ($5{\mu}l$) placed on Makler counting chamber(Sefi medical instrument, Israel) prewarmed at $37^{\circ}C$. The same person used the same micropipette to fill the Makler counting chamber. A total of 150 or more of sperms were analysed in each specimen by a single trained person by scanning at least 5 to 10 fields. The oocytes collection, in vitro maturation, IVF, in vitro culture and determination of the cleavage rate were performed by the technique, as described by Hwang et al (1997). Statistical analysis was done by linear regression with use of the Sigma plot program on a IBM personal computer. The cleavage rate in vitro fertilized oocyte was significantly correlated(P<0.05) with MOT, VCL, VSL, VAP, ALH, BCF and MAD, but not CON, LIN, STR, WOB, DNM, DNC and HYP in regressional analysis. The results show that some kinematic characteristics of frozen-thawed semen by CASA can be predict the fertility in in vitro model system.

  • PDF

A study on user satisfaction in TUI environment (TUI 환경의 유저 사용 만족도 연구)

  • Choi, heungyeorl;Yang, seungyong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.4
    • /
    • pp.113-127
    • /
    • 2015
  • An interface in smart device environment is changing to TUI(touch user interface) environment where a system is being controlled by physical touch, differently from a system controlled through conventional mouse and keyboard. What is more important than anything else in this TUI environment is to implement interface in consideration of learn ability and cognitive constructivism according to user's experience. Therefore, now is the time when it is necessary to carry out various studies on smart content design process going a step farther together with discussing the details of user's experience factor. Hence, this study was intended to look into what effect a user's experiential traits had on the production of contents for the purpose of measures for improving TUI user satisfaction in order to effectively realize contents in smart environment. Results were yielded by using a statistical empirical analysis such as cross-tabulation analysis according to important variable and user, paired t-test, multiple response analysis, and preference frequency analysis of user preference on the basis of a survey. As a result, a system was presented for implementing DFSS(Design For Six Sigma) process. TUI experience factor can be divided into direct habitual experience, direct learning experience, indirect habitual experience, and indirect learning experience. And in the results of study, it was possible to find that the important variables of this study had a positive effect on the improvement of use satisfaction with contents on the whole according to the user convenience of smart contents. This study is expected to have a positive effect on efficient smart device-based contents production by providing objective information according to empirical analysis to smart media-based developer and designer and presenting a model for improving the changed TUI usability.

Crystallographic Studies of Dehydrated Zeolite-X Reacting with Rubidium Vapor (루비듐 증기로 처리한 탈수한 제올라이트 X의 결정학적 연구)

  • Han, Young Wook
    • Journal of the Mineralogical Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.116-121
    • /
    • 1993
  • A single crystla of zeolite $Na_{78}Rb_{28}-X$ (approximate composition) was prepared by exposing $Na_{92}-X$ at $350^{\circ}C$ to 0.1 Torr of rubidium vapor, and its structure was determined by single-crystal x-ray diffraction methods in the cubic space group, Fd3, ${\alpha}=25.045(4){\AA}$. The structure was refined to the final error indices $R_1=0.082$ and $R_2=0.084$ with 353 for which I>$3{\sigma}(I)$. Only about 28 of the 92 $Na^+$ ions per unit cell were reduced and only about 14 of the 28 $Na^0$ atoms produced were retained within the zeolite. A $Na_5{^{4+}}$ cluster is present within each sodalite cavity. It is a centered tetrahedron (like $CH_4$) with bond $length=2.80(2){\AA}$ and angle tetrahedral by symmetry, and shows the full symmetry of its site. $T_d$, at the center of the sodalite cavity. Each of the four terminal atoms of the $Na_5{^{4+}}$ cluster bond to three framework oxygens at $2.36(2){\AA}$. At the centers of some double 6-rings are sodium atoms which bridge linearly between $Na_5{^{4+}}$ clusters to form agglomerations such as short zig-zag chains $Na_5{^{4+}}$ clusters. Delocalized electrons, located primarily on the sodiums at centers of the sodalite and (likely) double-six-ring cavities, contribute to the stability of the clusters.

  • PDF

The Study on influence of test factors for WorldSID injury through AE-MDB side crash test (AE-MDB시험 시 인체모형 상해치에 대한 시험 인자 영향성 연구)

  • Sun, Hongyul;Han, Pyokyong;Oh, Eunkyung;Yoon, Ilsung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2015
  • NCAP(New Car Assessment Program) makes vehicle manufacturer improve safety performance through free competition and customers guarantee vehicle selection by providing information of vehicle safety. That's why it is important not only to meet the regulation, but also to cope with NCAP. EuroNCAP(European New Car Assessment Program) side tests have conducted by using Progressive MDB and Euro SID II in order to reproduce crash test between two vehicles over 10 years. However various researches report that Progressive MDB and Euro SID II do not reflect evolving vehicle design, impact performance and biofidelity of human. Therefore EuroNCAP has the plan to conduct AE-MDB side crash test using WorldSID which is more evolved from 2015 by replacing Progressive MDB and EuroSID II. Automobile manufacturers need to develop safety performance for new test closely. This paper is to find test set-up parameters which affect into dummy injury instead of restraint system and to research on its tendency. It is processed with mini and small car to know influence as changing vehicle size and also analyzed by DFSS(Design for six sigma) which is one of optimization tools. DFSS is vaildated by simulating CAE with L18 orthogonal array of 6 control factors adjustable as EuroNCAP requirement.

MEASURING PERFORMANCE IN EGYPTIAN CONSTRUCTION FIRMS APPLYING QUALITY MANAGEMENT SYSTEMS

  • Manal S. Abd Elhamid;Sahar. Sh. Ghareeb;Ramadan O. Mohamed
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.149-156
    • /
    • 2011
  • The performance measurement of construction firms is considered as a competitive advantage to develop and improve their performance to have place in the market and stay able to face the continuous challenge. Egyptian construction firms (ECF) started recently to adopt quality management system (QMS) as a way to develop and improve their performance as previous studies showed. However, measuring that performance to include all the firm's aspects in a competitive way is a crucial process for the ECF's culture. The research is trying to indicate the role of the QMS implementation in measuring performance (MP) through developing a model for measuring performance on the organization level, and explore its impact on the organization that adopt quality management system. This model is based on specific elements and their related indicators which have been derived from national approaches and models of measuring performance (benchmarking, quality awards and six sigma).Elements determination and the status of their real practice has been investigated through a questionnaire to a representative sample of ECF. This model determines the performance level (PL) of the organization that measured by a mean of a point system. Weights of the elements in the point system considered both the elements' importance in the international models and its real practice in the Egyptian construction firms. So, the final outcome of the model reveals the level of firm performance that helps the firm to identify the weak points against the strong ones, Confirm the priorities and identify new opportunities for developing, and Check the position of the company in the market among the others. Another questionnaire has been developed to be distributed on a group of Experts on measuring performance for the purpose of model validation. The majority of surveyed experts agreed that the proposed model can be applied effectively.

  • PDF

Agent Based Process Management Environment (에이전트 기반의 프로세스 관리 환경에 관한 연구)

  • Kim, Jeong-Ah;Choi, Seung-Young;Choi, Sung-Woon
    • The KIPS Transactions:PartD
    • /
    • v.13D no.5 s.108
    • /
    • pp.691-698
    • /
    • 2006
  • The companies need the enterprise-wide support environment to build the competency to gather VOM(Voice of Market) in the process of preparing and implementing the strategy and to help establishing and managing the business process in order to secure the continuous competitive edge The enterprise-wide support environment to establish, operate, improve and evaluate the business process must be carried out. In this paper we define the method to define process and business rule in order to enable accurate execution of the process. Furthermore, collection and refection of accurate data concerning the competency of individuals, the subjects of the process execution, allows prevention of weakness of the process execution result and is the basis for identifying the areas of improvement. Therefore, high visibility can be attained through the work knowledge and processes presented in rules, and it can help firmly establish the process centered work culture (or system) in the organization by process improvement strictly based on data.

On the asymptotic correlationship for some process capability indices Ĉp, Ĉpk and Ĉpm (공정능력지수 Ĉp, Ĉpk와 Ĉpm를 위한 점근적 상관성에 관한 연구)

  • Cho, Joong-Jae;Yu, Hye-Kyung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.3
    • /
    • pp.465-475
    • /
    • 2013
  • Higher quality level is generally perceived by customers as improved performance by assigning a correspondingly higher satisfaction score. Usually, the quality level is measured by process capability indices. The index is used to determine whether a production process is capable of producing items within a specified tolerance. Some useful process capability indices $C_p$, $C_{pk}$ and $C_{pm}$ have been widely used in six sigma industries to assess process performance. Most evaluations on process capability indices focus on point estimates, which may result in unreliable assessments of process performance. It is necessary to investigate their asymptotic correlationship among process capability indices $\hat{C}_p$, $\hat{C}_{pk}$ and $\hat{C}_{pm}$. In this paper, we study their asymptotic correlationship for some process capability indices $\hat{C}_p$, $\hat{C}_{pk}$ and $\hat{C}_{pm}$ under the normal process.

EFFECT OF CALCIUM HYDROXIDE REMNANT AS AN INTRACANAL DRESSING ON THE APICAL LEAKAGE (근관내 잔존 Calcium Hydroxide제재가 치근단 미세누출에 미치는 영향)

  • 신수일;조용범
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.77-85
    • /
    • 2001
  • The purpose of this in vitro study was to compare the apical leakage in extracted teeth filled with gutta-percha subsequent to dressing with one of three different calcium hydroxide preparations. Thirty six extracted teeth with single canal were used in this study. After working length determination, canals were prepared with K flexo files to a #40 at the working length. Step-back flaring was produced by using #45, #50 K flexo files and #2, #3, #4 Gates Glidden burs. The teeth were randomly divided into 3 groups of 10 each : the remaining six teeth were used for negative and positive leakage control: Group 1, dressed with pure calcium hydroxide powder (Sigma, USA) mixed with distilled water; Group 2, dressed with Metapaste (Metadent, Korea) ; Group 3, dressed with Vitapex (Neo Dental, Japan). Teeth were sealed with Caviton (GC, Japan) and incubated in 100% humidity, at 37$^{\circ}C$ for 1 wk. All kinds of calcium hydroxide were removed from the canal with a MAF and 5% NaOCl. The canals were filled with AH-26$^{\circledR}$ sealer and gutta-percha using lateral condensation technique, incubated in 100% humidity, at 37$^{\circ}C$ for 2 days for the sealer to be set. The teeth were coated twice with nail varnish except for an area of approximately 2mm surrounding the apical foramen. All specimens were placed in 2% methylene blue solution for 2 days. The root were sectioned longitudinally, the amount of apical leakage was measured to the most coronal part of the root canal to which the dye had penetrated. The independent measurements were made for each root using a stereomicroscope ($\times$40 magnification) and the average was recorded for statistical analysis. The results were as follows ; 1. The mean of apical leakage in group of pure calcium hydroxide ranged 0.102$\pm$0.156mm, in Metapaste$^{\circledR}$ ranged 0.062$\pm$0.069mm, and in Vitapex$^{\circledR}$ ranged 0.067$\pm$0.072mm. 2. Group of pure calcium hydroxide exhibited more leakage than those of 2 manufactured calcium hydroxide preparations, but it was not statistically significant. 3. Group of water-based Metapaste$^{\circledR}$ showed lesser leakage than that of oil-based Vitapex$^{\circledR}$, but it was not statistically significant.

  • PDF

Injury Study for Q6 and Q10 Child Dummies (Q6, Q10 어린이 인체모형의 상해치 연구)

  • Sun, Hongyul;Lee, Seul;Seok, Juyup;Yoo, Wonjae;Yoon, Ilsung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.8 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • The Child Occupant Safety Assessment was first introduced and carried out by Euro NCAP in 2003, with the goal of ensuring manufacturers to develop safe vehicles for passengers of all ages; the objective was to evaluate the safety and protection offered by different Child Restraint Systems (CRS) in the event of a crash. In 2013, the formerly used P child dummy series was replaced by newer and more biofidelic Q1.5 and Q3 child dummies, representing 1.5 and 3 year old children respectively. The frontal and side impact dynamic performances of the Q1.5 and Q3 were tested within all classes of vehicles assessed by Euro NCAP at the time. As an extension to that initiative, Q6 and Q10 child dummies were later developed representing children of 6 and 10 years old. Since the protection of larger children during vehicle crashes relies greatly on the interaction of vehicle restraint systems such as seat belt and the CRS, instrumented Q6 and Q10 dummies will be used to assess the protection offered in the event of front and side impact crashes. In this paper, we focused on injury criteria of Q6 and Q10 child dummies at 64 kph 40% offset frontal crash test. The whole procedure was designed with DFSS analysis. The full vehicle sled test results of both dummies were conducted with different restraint systems settled through previous sled test. It showed that several injury criteria and image data were collected as the result of the full vehicle sled test. Based on the results of these investigations, this paper describes which factor is most important and combination shows the best performance when evaluating rear seat occupant protection for Q6 and Q10 child dummies.

Motional kinematics of Frozen-thawed Korean native cattle semen use of computer aided semen analysis(CASA) system (컴퓨터 정액자동분석에 의한 동결융해 한우 정액의 운동특성 연구)

  • Lee, Kang-nam;Lee, Byeong-chun;Kim, Jung-tae;Park, Jong-im;Shin, Tae-young;Hwang, Woo-suk
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.898-908
    • /
    • 1998
  • The aim of this experiments were to assess the time-interval change of motional characteristics in frozen-thawed semen of Korean native cattle (KNC) by using computer aided semen analysis (CASA) technology. Twenty-six KNC frozen semen straws were obtained from Korean KNC improvement department, livestock improvement main division, national livestock cooperatives federation in Korea. Specimens were allowed to thaw at $37^{\circ}C$ for 30 sec in water bath. Semen analysis was performed on semen image analysis system (SIAS, Medical supply, Korea) adjusted to the gate settings and used the semen droplet ($5{\mu}l$) placed on Makler counting chamber (Sefi medical instrument, Israel) prewarmed at $37^{\circ}C$. The same person used the same micropipette to fill the Makler counting chamber. A total of 150 or more of sperms were analysed in each specimen by a single trained person by scanning at least 5 to 10 fields. The measurement parameters in SIAS were as follows ; frame rate = 30 frames per sec, image capture = 1 sec, minimum motile speed = $10{\mu}m/s$, maximum countable sperm number = 400. Statistical analysis was done by Student t-test with use of the Sigma plot program on a IBM personal computer. The dancemean(DNM) and hyperactivated sperm(HYP) of frozen-thawed KNC semen kinematics were significantly decreased(p < 0.05) after 10 min of incubation at $37^{\circ}C$ water bath. But, wobble(WOB) of same sample semen was significantly increased(p < 0.05) after 10 min of incubation and significantly decrease(p < 0.05) after 60 min of same incubation. And, after 30 mim of incubation, significantly differences were found most of motion kinematics, motifity(MOT), curvilinear velocity(VCL), straight line velocity(VSL), average path velocity(VAP), amplitude of lateral head displacement(ALH), beat cross frequency(BCF), mean angular displacement(MAD), dance(DNC), on same sample semen. The DNM of KNC semen sample was variable kinematics after 30 min of incubation. Also, the linearity(LIN) and straightness(STR) was significantly decreased(p < 0.05) from 60 min of incubation. In conclusion, the AI within 30 min after thawing of frozen semen can be an effective method for obtaining high fertility rate in KNC reproductive program.

  • PDF