• Title/Summary/Keyword: Sitting Pressure

Search Result 143, Processing Time 0.028 seconds

Clothing Pressure of selected Support Panty Stockings

  • Park, Jeong-Eun;Sung, Su-Kwang;Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.430-436
    • /
    • 2000
  • The purpose of the study was to obtain the basic data on the self-adjusting ability of the support panty stockings. Ten healthy women in the twenties were selected as subjects and clothing pressure of 9 support panty stockings made of single covered yarn (SCY) and double covered yarn (DCY) were measured under the standard environmental condition for the study. Data was analysed statistically according to body postures, sides, and parks. The results were as follows: Clothing pressure according to body posture was order of 'sitting-on-a-chair', 'stepping-up-a-stair', and 'standing'. High clothing pressure was obtained in the parts of calf ($9.4gf/cm^2$) in 'standing' and knee (9.7 and $16.5gf/cm^2$) in both 'stepping-up-a-stair' and 'sitting-on-a-chair', respectively. The order of clothing pressure with body sides was 'front', 'side', and 'back'. The highest clothing pressure was knee ($18.8gf/cm^2$) on the front, thigh ($8.8gf/cm^2$) on the side, and calf ($6.4gf/cm^2$) on the back. Clothing pressure of DCY at abdomen and knee was a little higher than those of SCY 3. In terms of material structure variation, clothing pressure of thigh, calf and ankle with SCY was a little higher than those with DCY, while clothing pressure of abdomen and knee with DCY was a little higher than those with SCY.

  • PDF

Effects of the Probody Massage on the Physical Characteristics, Gross Motor Function and ROM in Youth with Cerebral Palsy : Case study (프로바디마사지가 뇌병변 장애우의 신체적 특성과 대동작 기능 및 관절 가동범위에 미치는 영향 : 사례연구)

  • Kim, Eui-Suk;Yang, Jeong-Ok;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.4
    • /
    • pp.453-463
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effects of the Probody Massage Program on the physical characteristics, gross motor function and ROM (Range Of Motion) of children with cerebral palsy. Method : The subjects of this study were two children who have been diagnosed with first grade cerebral palsy that utilized T development support center located in B Metropolitan city for 8 weeks, twice a week, to carry out the Probody Massage Program for 30 minutes. Physiological reactions (height, weight, BMI, blood pressure (an index of inflammation), pulse rate) and large operating functions (sitting, crawling and the joints' range of motion as an angle of the shoulders' upper limb articulation) were measured pretest, after 4 weeks, and after 8 weeks. Results : The Probody Massage Program showed positive changes in physical characteristics (blood pressure, sitting, and crawling), gross motor function (upper limb shoulder movement), joint range of motion, height, body weight, metabolic activation and blood circulation of children with cerebral palsy. Conclusion : We believe making a practical impact on the growth and development, functional recovery of daily life, and improvement of quality of life of children with cerebral palsy by utilizing Probody Massage Program improves blood pressure (an index of inflammation), pulse, sitting, crawling, and the joints' range of motion as an angle of the shoulder joints' upper limb movement of children with cerebral palsy.

Development of Tilting Chair for Maintaining Working Position at Reclined Posture

  • Hyeong, Joon-Ho;Roh, Jong-Ryun;Park, Seong-Bin;Kim, Sayup;Chung, Kyung-Ryul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • Objective: The aim of this study is to develop an office chair enabling to keep working at reclined sitting posture. Background: Sedentary workers are supposed to change the posture frequently during long hours of sitting. A reclined sitting position has been recommended to reduce disc pressure. But slumped sitting posture caused by the buttock sliding forward without any adjustment of back reclining is commonly observed. The worker seems to have tendency to change the sitting posture maintaining working condition. We assumed the reason to be their hands movement away from the working space when tilting backward. Method: Slide mechanism allowing seat to move forward was designed to maintain the hand position in working space during reclining. A prototype was manufactured and tilting motion was analyzed using motion capture system. Four experiment chairs were tested including the manufactured prototype chair and three other commercial chairs. Results: A backward movements of the hand position were 13.0mm, 101.7mm, 156.1mm and 139.3mm at the prototype chair, compared to chair B, chair C and chair D, respectively. And the movement was remarkably small at the prototype chair. Conclusion: The developed seat sliding chair allows back tilting maintaining hand position at working space. We expect the user tilting back more often than normal tilting chair during seated work. But further investigation is required to figure out the effectiveness of the developed chair using prolonged working hours. Application: The developed office chair directly affects commercialization.

Effect of Chin Tuck Exercises on Various Postures and Muscle Activity of the Neck and Shoulder (다양한 자세에 따른 턱 당기기 운동이 목과 어깨의 근활성도에 미치는 영향)

  • Ahn, Su-Hong;Yang, Ju-Hui;Lee, Su-Kyong;Park, Jin-Sung;Jo, Jae-Sung
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.403-414
    • /
    • 2020
  • Purpose: This study examined how performing chin tuck exercises in supine, sitting, and standing positions affects changes in the muscle activity of the neck and shoulder. Methods: Seventeen men and three women with forward head posture participated in the study. The subjects performed the chin tuck exercise using a pressure biofeedback unit. After determining the ideal order for performing the chin tuck exercise in supine, sitting, and standing positions through randomized controlled trials, muscle activity was measured in the dominant-side sternocleidomastoid, scalenus anterior, upper trapezius, and levator scapulae. Muscle activity was measured three times in each muscle for each position, and the average of the three measurements was used for analysis. Results: In this study, the chin tuck exercise performed in a supine position reduced muscle activity of the sternocleidomastoid, scalenus anterior, upper trapezius, and levator scapulae significantly more than performing the exercise in either sitting or standing positions (p < 0.05). No significant difference in muscle activity was observed when the exercise was performed in a sitting position versus a standing position (p < 0.05). Conclusion: Performing a chin tuck exercise in a supine position is more effective for stabilizing the neck and shoulder than performing it in a sitting or standing position, as it reduces excessive tension and fatigue in the neck and shoulder.

Evaluation of Seat Comfort and Pressure Distribution According to the Ergonomic Design of Automobile Seats (자동차 시트의 인간공학적 디자인에 따른 착좌 안락감 및 압력분포 평가)

  • Halim Chung;Jun Won Choi;Seung Wan Yang;Chun Kyu Park;Do Yong Kim;Chang Hyun Song;Jong Bae Kim;Han Sung Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.157-165
    • /
    • 2023
  • The purpose of this study was to evaluate the importance of developing slim seats with ergonomic design to improve seat comfort and expand the interior space. Two seats were used for the experiment: a sample seat designed based on hip shape and spinal alignment and a normal seat with a flat design without curves. Subjects sat in both the sample seat and a normal seat applied to the vehicle simulator and the experiment was conducted. The next part of the experiment was conducted in two different postures: a driving posture and a relaxed posture. The subjects filled out a comfort questionnaire immediately after sitting and after 30 minutes. The results showed that the comfort in the sample seat was found to be more comfortable than the normal seat. However, no significant difference was noted for the relaxation posture. Pressure distribution was also recorded immediately after sitting and after 30 minutes. In the case of pressure distribution, it was confirmed that the pressure in the sample seat was more evenly distributed in both the driving and relaxed postures than in the normal seat. The results showed that the ergonomically designed sample seat greatly improved seating comfort and pressure distribution compared to the normal seat, which is a general vehicle seat design.

Development of the physical pressure measurement device and orthodontic chair to prevent pressure sores (욕창 예방을 위한 체압 측정 장치 및 교정용 의자 개발)

  • Kang, Dong-Won;Kim, Kyoung-Myoung;Jang, Kyung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1974_1975
    • /
    • 2009
  • The chairbound, handicapped person often requires a cushion to distribute the supportive forces over the largest area possible in order to reduce the risk of the development of a pressure sore. Pressure sores are areas of damaged skin caused by staying in one position for too long and can cause serious infections, some of which are life-threatening. When sitting upright, the greatest proportion of body weight is centerd over the ischial tuberosities. So, it is important that comfortable seating and largest distribution of pressure to prevent pressure sores. Therefore, the objective of this study was to develop the physical pressure measurement device and orthodontic chair to prevent pressure sores.

  • PDF

A study on the clothing pressure - Focusing the Men's Waist - (의복압에 관한 연구-남자의 허리부위를 중심으로-)

  • 송명견
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 1986
  • There is hardly any helpful data from the studies on the clothing pressure of men, because most studies about the clothing pressure have been attempted to analyze the case of women. This study, therefore, was done about the men's waist which was most highly pressured of the body. RESULTS: 1. The pressure from the waist when the man puts on summer wears was as follow ; the case when standing, the pressure from the abdomen was 28.99±14.37g/㎠, and the one from the side 34.14±14.79g/㎠, the case when sitting on the chair, the pressure from the abdomen was 31.27±15.59g/㎠, and the one from the side was 33.39±13.23g/㎠. 2. The pressure from the abdomen was increased in proportion to the Rohrer index. 3. The clothing pressure given the waist was lower in case of the men with digestive disorder than the ordinary ones.

  • PDF

The Effect of Foot Bath on Blood Pressure Following Treadmill Exercise (트레드밀 운동 후 족욕이 혈압에 미치는 영향)

  • Lee, Sang-Youl;Lee, Myung-Hee;Yun, Chang-Goo;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.2
    • /
    • pp.97-102
    • /
    • 2008
  • Purpose : The purpose of this study was to find the effect of foot bath on blood pressure(BP) following treadmill exercise. Methode : Subject of study were forty healthy males without any cardiovascular, musculoskeletal, and neurologic diseases. Following twenty minutes walking at a speed of 5m/s on the treadmill, ten twenty subjects in experimental group received foot bath, on the dominant lower limb while sitting in chair. Foot bath was applied to the level of the lateral and medial malleoli keeping the temperature of the paraffin bath at $40{\pm}0.5^{\circ}C$. Twenty subjects in control group took a rest sitting in chair in a comfortable position. BP was measured in right brachial artery. BP was measured five times(before exercise, immediately after exercise, 5 minutes, 10 minutes, and fifteen minutes after exercise). Results : The study showed that for diastolic blood pressure, there was no significant difference between the experimental and the control group. However, systolic blood pressure(SBP) increased significantly after exercise compared with SBP before exercise (p<.05). In addition, SBP in five minutes after exercise decreased significantly compared with SBP in immediately after exercise (p<.05). On the other hand, the control group had significant difference between SBP measured before exercise and SBP measured at the other measure time (p<.05). In five minutes after exercise, SBP in experimental group had significant difference with SBP in control group (p<.05). Similarly, in ten and fifteen minutes after exercise, SBP in experimental group had significantly difference with SBP in control group (p<.05). Conclusion : Consequently it was confirmed that when foot bath was applied, the increased BP induced by the exercise returned to normal range rapidly.

  • PDF

Development of Ergonomic Balance Seat(e-BASE) Chair

  • Park, Jae Hee;Kim, Seung Hee;Kim, Min Uk;Jung, Hanbum;Shim, Young Soo;Ryu, Taehee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.145-152
    • /
    • 2013
  • Objective: The aim of this study is to develop an ergonomic office chair that has an alarm function for the unbalanced sitting postures. Background: Contrary to expectation, it is reported that office workers sit on their chairs much more in unbalanced postures during daily work. Even though an office worker uses an ergonomically good-designed chair and begins their work in a good sitting posture, his/her posture is likely to shift to the unbalanced bad posture. Therefore, a posture alarm system would be very helpful in keeping office workers' good postures. Method: We developed a prototype chair with four load cells under a seat pan and one load cell beneath a backrest. Through some experiments, we set the criteria for unbalanced bad postures then implemented the criteria into the alarm system of the prototype chair. The chair called e-BASE chair could detect unbalance postures and show alarms for chair users. We also enhanced back support by developing a step-wised folding backrest. Results: The e-BASE chair showed better performance in interface pressure distributions and balanced posture ratio in VDT work. Conclusion: The ergonomic chair with posture alarm function(e-BASE chair) was developed. It showed better performance in seat pressure distribution and in keeping good posture during office work. Application: The posture alarm system and folding backrest can be applied to the new models of office chair.